20:1 Implant Contra-Angle Handpiece

Explore Kaneiko 20:1 implant speed-reducing contra-angle handpieces engineered to reduce motor speed to 1/20 while delivering high torque at speeds up to 2,000 rpm. Compatible with RA latch-type and CA long implant burs, this collection supports implant site preparation, osteotomy drilling, dental implant placement and surgical thread tapping with controlled low-speed performance and precise torque transmission.

Skip to results list
1 item
Column grid
Column grid

Filter

  • Model I20L 20:1 Implant Surgical Contra-Angle Handpiece for Osteotomy & Implant Placement

    Model I20L 20:1 Implant Surgical Contra-Angle Handpiece for Osteotomy & Implant Placement

    Model I20L 20:1 Implant Surgical Contra-Angle Handpiece for Osteotomy & Implant Placement

    Sale price  $669.00 Regular price  $836.00
20:1 Implant Contra-Angle Handpiece Series

More About 20:1 Implant Contra-Angle Handpieces

Kaneiko 20:1 implant contra-angle handpieces are speed-reducing surgical instruments designed for controlled dental implant drilling, osteotomy preparation and implant placement. Their 20:1 reduction transmission lowers the rotational speed supplied by a compatible implant motor while supporting stable torque delivery and precise instrument movement.

Both handpieces in this collection operate at speeds of up to 2,000 rpm, depending on the connected implant motor and programmed settings. They accept RA latch-type burs and compatible implant instruments with a standard Ø2.35 mm shank.

The collection includes the Model I20L 20:1 Implant Surgical Speed-Reducing Electric Contra-Angle Handpiece with fibre-optic illumination, ceramic bearing and Black Nano Titanium body, and the Model CA2001 Economic Implant Contra-Angle Handpiece with a non-optic stainless steel configuration.

Both models use single-point external water spray to direct irrigation toward the implant drill and surgical site. The correct option should be selected according to the implant motor, illumination requirements, bearing system, body material and intended surgical workflow.

Introducing 20:1 Implant Handpieces in Implant Dentistry

Implant osteotomy preparation requires a different operating approach from high-speed restorative dentistry. Instead of prioritising maximum rotational speed, implant procedures require controlled drilling, stable torque transmission, effective irrigation and precise instrument positioning.

A 20:1 implant contra-angle reduces the speed generated by the implant motor. For example, a compatible motor operating at 40,000 rpm can provide a nominal output of approximately 2,000 rpm through a 20:1 reduction system.

This lower-speed configuration supports sequential osteotomy drilling, implant-site preparation and controlled implant insertion according to the selected implant system protocol.

The angled handpiece design also improves intraoral access compared with a straight surgical handpiece, particularly in posterior implant sites where visibility and instrument positioning may be restricted.

What Are 20:1 Implant Contra-Angle Handpieces Used For?

Dental Implant Osteotomy Preparation
Used with compatible implant drills to prepare the osteotomy according to the planned implant diameter and length.

Sequential Implant Drilling
Supports the progressive drilling sequence specified by the selected dental implant system.

Implant-Site Preparation
Provides controlled rotational movement for preparing bone before implant insertion.

Controlled Implant Placement
May be used with compatible implant drivers for controlled implant insertion according to the prescribed speed and torque settings.

Implant Thread Tapping
Supports compatible thread-tapping procedures when required by the implant design, bone density and manufacturer’s surgical protocol.

Low-Speed Surgical Drilling
Suitable for compatible oral surgical procedures requiring reduced rotational speed and external irrigation.

Posterior Implant Procedures
The contra-angle head supports improved access and instrument positioning in posterior treatment areas.

Kaneiko 20:1 Implant Contra-Angle Handpieces: Engineered for Surgical Control

Kaneiko implant contra-angle handpieces are designed around the clinical requirements of implant surgery: controlled speed reduction, stable instrument rotation, external irrigation, secure bur compatibility and reliable implant motor connection.

Key design priorities include:

  • 20:1 speed-reducing transmission
  • Maximum rotation up to 2,000 rpm
  • Compatibility with electric implant motors
  • RA latch-type and compatible implant instrument acceptance
  • Standard Ø2.35 mm instrument shank compatibility
  • Single-point external water spray
  • Fibre-optic and non-optic configurations
  • Black Nano Titanium or stainless steel body options
  • Clean Head System
  • Model-specific bearing and protective features

These configurations allow clinicians and procurement teams to select either a feature-rich fibre-optic implant handpiece or a more economical non-optic option for compatible implant motor systems.

Model Comparison

Feature Model I20L Model CA2001
Product Type Implant Surgical Contra-Angle Economic Implant Contra-Angle
Transmission Ratio 20:1 Speed Reducing 20:1 Speed Reducing
Maximum Rotation Up to 2,000 rpm Up to 2,000 rpm
Light Transmission Fibre Optic No Light
Water Spray Single-Point External Water Spray Single-Point External Water Spray
Body Material Black Nano Titanium Stainless Steel
Bearing Ceramic Bearing Bearing System
Bur Compatibility RA Burs and Implant Instruments, Ø2.35 mm RA Burs and Implant Instruments, Ø2.35 mm
Protective Features Clean Head and Anti-Heat Systems Clean Head System
Motor Compatibility Compatible Electric Implant Motor Compatible Implant Motor
Recommended Application Implant and Surgical Use Implant Motor and Implant Use

Model I20L 20:1 Implant Surgical Contra-Angle Handpiece

The Kaneiko Model I20L is designed for controlled implant drilling and compatible oral surgical procedures requiring fibre-optic illumination and stable rotational performance.

Its 20:1 reduction transmission supports output speeds of up to 2,000 rpm when connected to a compatible electric implant motor. The ceramic bearing supports smooth instrument rotation during osteotomy preparation, sequential drilling and implant insertion.

Fibre-optic light transmission carries illumination from a compatible implant motor toward the surgical site, supporting improved visibility during posterior and restricted implant procedures.

The Black Nano Titanium body provides a durable premium surface, while the Clean Head and Anti-Heat Systems support internal protection and temperature management during operation.

Model CA2001 Economic Implant Contra-Angle Handpiece

The Kaneiko Model CA2001 is an economical 20:1 implant contra-angle designed for clinics requiring controlled implant-motor operation without fibre-optic light transmission.

The stainless steel body provides a durable structure for routine implant and surgical use. Its 20:1 reduction transmission supports rotation of up to 2,000 rpm, depending on the connected implant motor and selected settings.

Model CA2001 uses a single-point external irrigation pipe and accepts RA latch-type burs and compatible implant instruments with a standard Ø2.35 mm shank.

The non-optic configuration is suitable for implant motor systems that do not require illumination through the handpiece. External operatory lighting should be used when additional visibility is needed.

20:1 Speed-Reducing Transmission

A 20:1 transmission reduces the rotational speed supplied by the implant motor to one twentieth at the handpiece output.

This reduction allows the instrument to operate at controlled surgical speeds while supporting torque transmission for implant drilling and placement. The actual output speed depends on the programmed motor setting.

The maximum specified rotation for both Kaneiko models is up to 2,000 rpm. Lower speeds should be selected according to the drill, implant system, bone condition and surgical protocol.

Implant drilling speeds, insertion speeds and torque limits should always follow the implant system manufacturer’s instructions.

Clinical Benefits

Controlled Low-Speed Implant Drilling
The 20:1 reduction ratio supports precise osteotomy preparation at implant-specific rotational speeds.

Stable Torque Transmission
The reduced-speed gear system supports controlled power delivery during drilling and implant insertion.

Improved Intraoral Access
The contra-angle head helps position implant drills in posterior and restricted surgical areas.

External Surgical Irrigation
Both models direct cooling fluid toward the implant drill and osteotomy site through a single-point external spray pipe.

Fibre-Optic and Non-Optic Options
Clinics can select Model I20L for fibre-optic illumination or Model CA2001 for a more economical non-optic setup.

RA and Implant Instrument Compatibility
Both models accept compatible Ø2.35 mm latch-type instruments used in implant surgical workflows.

Model-Specific Construction
Choose a Black Nano Titanium body with ceramic bearing or a stainless steel economic configuration according to clinical and budget requirements.

Buying Considerations

  • Confirm compatibility with the intended implant motor
  • Check the physical E-type or implant motor connection before ordering
  • Confirm the motor’s speed and torque control range
  • Select fibre-optic or non-optic configuration according to the clinical setup
  • Use compatible RA latch-type or implant instruments with a Ø2.35 mm shank
  • Confirm the required drill length and implant-system compatibility
  • Check the external irrigation tubing and saline delivery setup
  • Review bearing type and body material
  • Confirm cleaning, lubrication and sterilisation requirements
  • Check servicing and replacement-component availability

The appropriate implant contra-angle should be selected according to the implant motor, surgical protocol, illumination requirements, irrigation system and instrument compatibility rather than price alone.

How to Choose the Right 20:1 Implant Contra-Angle Handpiece

Choose Model I20L for Fibre-Optic Illumination
Select I20L when the compatible implant motor supports fibre-optic light transmission and improved surgical-site visibility is required.

Choose Model CA2001 for a Non-Optic Economic Setup
Select CA2001 when the implant system does not require light transmission through the handpiece and an economical stainless steel option is preferred.

Confirm Implant Motor Compatibility
Check the connection, speed range, torque settings, irrigation system and light-transmission capability before purchase.

Confirm Instrument Compatibility
Use RA latch-type burs and implant drills with a standard Ø2.35 mm shank that are approved for the selected handpiece and implant protocol.

Review the Intended Procedure
Select the handpiece according to whether it will be used for osteotomy drilling, implant placement, thread tapping or other compatible surgical applications.

Evaluate Visibility Requirements
Fibre-optic transmission can support posterior implant procedures, while non-optic models may be sufficient when operatory lighting provides adequate visibility.

RA and Implant Instrument Compatibility

Model I20L and Model CA2001 accept RA latch-type burs and compatible implant instruments with a standard Ø2.35 mm shank.

RA and CA are commonly used names for the same latch-type bur-shank format. However, not every Ø2.35 mm instrument is automatically suitable for implant surgery. Instrument length, cutting design, rotational-speed limit and implant-system compatibility must also be confirmed.

Implant drills should be selected according to the surgical kit and implant manufacturer’s recommended sequence. Do not substitute an unrelated restorative RA bur for a dedicated implant drill.

To understand the differences between dental bur systems, read the FG, RA and HP Bur Compatibility Guide for Dental Handpieces .

Before operation, confirm that the implant instrument is fully inserted, securely retained and approved for the selected speed and torque.

External Water Spray and Surgical Irrigation

Model I20L and Model CA2001 use a single-point external water spray system. The external irrigation pipe directs sterile cooling fluid toward the implant drill and surgical site.

Effective irrigation supports temperature management, debris removal and visibility during osteotomy preparation. The spray pipe should be positioned so that fluid reaches the working portion of the drill.

Before beginning the procedure, confirm that the irrigation tubing is connected securely, the saline supply is flowing and the spray outlet is not blocked.

External irrigation should be used according to the implant motor and implant-system instructions. Additional internal irrigation may be required for certain drills or surgical protocols.

Fibre-Optic vs Non-Optic Implant Handpieces

Model I20L includes fibre-optic light transmission. Illumination is carried from a compatible implant motor through the handpiece toward the operative area.

Fibre-optic visibility can support implant drilling and instrument positioning in posterior or restricted areas. The implant motor must support light transmission for this feature to function.

Model CA2001 does not include fibre-optic transmission. It is suitable for implant systems where external operatory or surgical lighting provides adequate visibility.

Light transmission does not affect the 20:1 reduction principle, but it may influence visibility and workflow during difficult-access implant procedures.

Implant Motor Compatibility

Both models are designed for use with compatible electric implant motors. They should not be connected to an unsuitable dental air motor or used as general restorative contra-angle handpieces.

The implant motor should provide programmable speed and torque settings appropriate for osteotomy preparation and implant insertion.

Before purchase, verify the physical connection, irrigation system, fibre-optic capability and motor-control range. A compatible mechanical connection alone does not confirm that every motor feature will function correctly.

Always program the implant motor according to the selected drill, implant design and manufacturer’s surgical instructions.

Maintenance and Sterilisation

Correct maintenance supports smooth gear transmission, bearing performance, water delivery and secure instrument retention.

After use, remove the implant drill, clean the exterior and flush the external irrigation system according to the handpiece instructions.

Lubricate the handpiece through the correct connection or maintenance adaptor when required. Operate the handpiece briefly to distribute the lubricant and remove excess oil before sterilisation.

Inspect the head, latch system, irrigation pipe and bearing movement regularly. Increased noise, vibration, heat, reduced rotation or loose instrument retention may indicate that servicing is required.

Read the Kaneiko Dental Handpiece Maintenance Guide for additional cleaning, lubrication, inspection, sterilisation and storage guidance.

Professional Insight

In implant dentistry, the handpiece should be selected as part of the complete surgical system rather than as an isolated instrument. Motor compatibility, implant drill design, torque settings and irrigation all affect clinical performance.

Model I20L is the more feature-rich option, combining fibre-optic illumination, a ceramic bearing and Black Nano Titanium body. Model CA2001 provides the same core 20:1 reduction and 2,000 rpm maximum speed in a non-optic stainless steel configuration.

The absence of fibre-optic illumination does not make an implant handpiece unsuitable, but it changes how visibility is managed during surgery. Clinics should consider posterior access, operatory lighting and surgical workflow when selecting between the models.

Neither model should be operated according to a universal speed or torque value for every implant procedure. The implant manufacturer’s drilling and insertion protocol should always determine the programmed motor settings.

Benefits of Using Kaneiko 20:1 Implant Contra-Angle Handpieces

  • Provide controlled 20:1 speed reduction for implant procedures
  • Support output speeds of up to 2,000 rpm
  • Connect to compatible electric implant motors
  • Support osteotomy preparation and sequential drilling
  • Accept Ø2.35 mm RA latch-type and implant instruments
  • Provide single-point external surgical irrigation
  • Offer fibre-optic and non-optic configurations
  • Provide Black Nano Titanium and stainless steel body options
  • Support controlled implant placement with compatible drivers
  • Offer premium and economical options for different clinical setups

Frequently Asked Questions

1. What is a 20:1 implant contra-angle handpiece?
It is a speed-reducing surgical handpiece that lowers the implant motor’s rotational speed to one twentieth at the instrument output.

2. What is the maximum speed of the Kaneiko implant handpieces?
Model I20L and Model CA2001 operate at speeds of up to 2,000 rpm, depending on the compatible implant motor and programmed settings.

3. What procedures are these handpieces used for?
They are used for implant osteotomy preparation, sequential drilling, implant-site preparation, compatible implant insertion and selected low-speed surgical procedures.

4. What is the difference between I20L and CA2001?
I20L has fibre-optic light transmission, a ceramic bearing and Black Nano Titanium body. CA2001 is a non-optic economic model with a stainless steel body and bearing-supported rotation.

5. What burs and instruments are compatible?
Both models accept RA latch-type burs and compatible implant instruments with a standard Ø2.35 mm shank.

6. Do both models include external irrigation?
Yes. Both use a single-point external water spray pipe to direct cooling fluid toward the implant drill and surgical site.

7. Can these handpieces be used with a dental air motor?
They are designed for compatible electric implant motors. Motor connection, speed control, torque control and irrigation compatibility should be confirmed before use.

8. Can a 20:1 implant handpiece be used for high-speed crown preparation?
No. Crown preparation generally requires a high-speed handpiece or a suitable speed-increasing electric contra-angle. A 20:1 handpiece is designed for reduced-speed implant and surgical workflows.

9. Is fibre-optic illumination required for implant surgery?
It is not essential in every setup, but it can improve visibility in posterior or restricted areas. Model I20L provides fibre-optic transmission, while Model CA2001 is non-optic.

10. How should an implant contra-angle handpiece be maintained?
Remove the instrument, clean the exterior, flush the irrigation pathway, lubricate according to the instructions, inspect the latch and spray pipe, sterilise correctly and allow the handpiece to dry before storage.

20:1 インプラント用コントラアングルハンドピース

20:1 インプラント用コントラアングルハンドピースについて

Kaneiko 20:1 インプラント用コントラアングルハンドピース は、インプラント窩形成、オステオトミー形成、 インプラント埋入などにおいて、 コントロールされた低速回転を提供するために設計された 減速式の外科用ハンドピースです。 20:1減速機構により、 対応するインプラントモーターから供給される回転速度を低減しながら、 安定したトルク伝達と精密な器具操作をサポートします。

このコレクションの両モデルは、 接続するインプラントモーターと設定に応じて 最大2,000 rpmで作動します。 標準Ø2.35 mmシャンクのRAラッチタイプバーおよび 対応するインプラント用器具に対応しています。

コレクションには、 Model I20L 20:1 インプラント外科用減速電動コントラアングルハンドピース と、 Model CA2001 エコノミー インプラント用コントラアングルハンドピース があります。

Model I20Lは、 光ファイバー照明、セラミックベアリング、 ブラックナノチタンボディを採用しています。 Model CA2001は、 光ファイバーを搭載しないステンレススチール仕様です。

両モデルとも、 1点外部注水スプレーによって インプラントドリルと術野へ冷却液を供給します。 使用するインプラントモーター、照明の必要性、 ベアリングシステム、ボディ材質、 外科ワークフローに応じて適切なモデルを選択してください。

インプラント治療における20:1 コントラアングルハンドピース

インプラントのオステオトミー形成では、 高速修復治療とは異なる作動条件が必要です。 最大回転速度を重視するのではなく、 コントロールされたドリリング、 安定したトルク伝達、 効果的な注水、 正確な器具位置決めが重要になります。

20:1 インプラント用コントラアングルは、 インプラントモーターが発生する回転速度を 20分の1に減速します。 例えば、対応するモーターを40,000 rpmで作動させた場合、 20:1減速機構による公称出力回転数は 約2,000 rpmとなります。

この低速構成により、 使用するインプラントシステムのプロトコルに従った 段階的なオステオトミードリリング、 インプラントサイト形成、 コントロールされたインプラント埋入をサポートします。

また、コントラアングル形状は、 ストレート外科用ハンドピースと比較して 口腔内へのアクセス性を高め、 特に視認性や器具位置決めが制限されやすい 臼歯部のインプラント処置をサポートします。

20:1 インプラント用コントラアングルハンドピースの主な用途

インプラントオステオトミー形成
対応するインプラントドリルを使用し、 計画されたインプラント径と長さに従って オステオトミーを形成します。

段階的なインプラントドリリング
使用するインプラントシステムで指定された 段階的なドリリングシーケンスをサポートします。

インプラントサイト形成
インプラント埋入前の骨形成に、 コントロールされた回転を提供します。

コントロールされたインプラント埋入
対応するインプラントドライバーを使用し、 指定された回転速度とトルク設定に従って インプラント埋入を行うことができます。

インプラントスレッドタッピング
インプラント設計、骨密度、 メーカーの外科プロトコルに応じて必要となる 対応するスレッドタッピング処置をサポートします。

低速外科ドリリング
低速回転と外部注水を必要とする 対応する口腔外科処置に使用できます。

臼歯部のインプラント処置
コントラアングルヘッドにより、 臼歯部やアクセスが制限される術野での 器具位置決めをサポートします。

Kaneiko 20:1 インプラント用コントラアングル:外科的コントロールを追求した設計

Kaneiko 20:1 インプラント用コントラアングルハンドピース は、インプラント外科に求められる コントロールされた減速、 安定した器具回転、 外部注水、 確実な器具適合性、 インプラントモーターとの接続性を考慮して設計されています。

主な設計ポイント:

  • 20:1 減速機構
  • 最大回転数 2,000 rpm
  • 対応する電動インプラントモーターとの接続
  • RAラッチタイプバーおよび対応インプラント器具に対応
  • 標準Ø2.35 mmシャンクに対応
  • 1点外部注水スプレー
  • 光ファイバー仕様・非光ファイバー仕様
  • ブラックナノチタン・ステンレススチールのボディ仕様
  • クリーンヘッドシステム
  • モデル別のベアリング・保護機構

これらの仕様により、 光ファイバーを備えた高機能なインプラント用ハンドピースと、 対応するインプラントモーター向けの よりシンプルな非光ファイバー仕様から選択できます。

Model I20L・Model CA2001 比較

項目 Model I20L Model CA2001
製品タイプ インプラント外科用コントラアングル エコノミー インプラント用コントラアングル
変速比 20:1 減速 20:1 減速
最大回転数 最大2,000 rpm 最大2,000 rpm
光伝送 光ファイバー なし
注水方式 1点外部注水スプレー 1点外部注水スプレー
ボディ材質 ブラックナノチタン ステンレススチール
ベアリング セラミックベアリング ベアリングシステム
対応バー・器具 RAバー・インプラント器具
Ø2.35 mm
RAバー・インプラント器具
Ø2.35 mm
保護機構 クリーンヘッド
アンチヒート
クリーンヘッド
モーター適合性 対応する電動インプラントモーター 対応するインプラントモーター
推奨用途 インプラント・外科用途 インプラントモーター・インプラント用途

Model I20L 20:1 インプラント外科用コントラアングルハンドピース

Kaneiko Model I20L は、光ファイバー照明と安定した回転性能を必要とする インプラントドリリングおよび 対応する口腔外科処置のために設計されています。

20:1減速機構により、 対応する電動インプラントモーターに接続した場合、 最大2,000 rpmの出力回転数をサポートします。 セラミックベアリングは、 オステオトミー形成、段階的なドリリング、 インプラント埋入時の スムーズな器具回転をサポートします。

光ファイバー伝送により、 対応するインプラントモーターから術野へ光を伝え、 臼歯部やアクセスが制限される インプラント処置での視認性をサポートします。

ブラックナノチタンボディを採用し、 クリーンヘッドシステムとアンチヒートシステムにより、 作動時の内部保護と温度管理をサポートします。

Model CA2001 エコノミー インプラント用コントラアングルハンドピース

Kaneiko Model CA2001 は、ハンドピースからの光伝送を必要としない インプラントモーター環境向けに設計された エコノミータイプの20:1インプラント用コントラアングルです。

ステンレススチールボディを採用し、 日常的なインプラント・外科用途に対応する 耐久性のある構造を備えています。 20:1減速機構により、 接続するインプラントモーターと設定に応じて 最大2,000 rpmで作動します。

Model CA2001は、 1点外部注水パイプを採用し、 標準Ø2.35 mmシャンクのRAラッチタイプバーおよび 対応するインプラント器具に対応します。

光ファイバーを搭載していないため、 必要に応じて診療用ライトや外科用照明によって 術野の視認性を確保してください。

20:1 減速機構

20:1の変速機構は、 インプラントモーターから供給される回転速度を ハンドピース出力側で20分の1に減速します。

この減速により、 インプラントドリリングや埋入に必要な コントロールされた外科用回転速度で作動しながら、 トルク伝達をサポートします。 実際の出力回転数は、 プログラムされたモーター設定によって異なります。

Kaneikoの両モデルで指定されている最大回転数は 2,000 rpmです。 実際の使用回転数は、 ドリル、インプラントシステム、 骨の状態、外科プロトコルに従って設定してください。

インプラントドリリング速度、 埋入速度、トルク上限は、 使用するインプラントシステムメーカーの 指示に従ってください。

臨床上のメリット

コントロールされた低速インプラントドリリング
20:1減速比により、 インプラント処置に適した回転速度での 精密なオステオトミー形成をサポートします。

安定したトルク伝達
減速ギアシステムにより、 ドリリングやインプラント埋入時の コントロールされた動力伝達をサポートします。

口腔内アクセスをサポート
コントラアングルヘッドにより、 臼歯部やアクセスが制限された外科部位での インプラントドリルの位置決めをサポートします。

外部外科注水
両モデルとも、 1点外部注水パイプから インプラントドリルとオステオトミー部位へ 冷却液を供給します。

光ファイバー・非光ファイバー仕様
光ファイバー照明が必要な場合はModel I20L、 非光ファイバーのシンプルな構成には Model CA2001を選択できます。

RAバー・インプラント器具に対応
両モデルとも、 インプラント外科ワークフローで使用される Ø2.35 mmラッチタイプの対応器具を装着できます。

モデル別のボディ・ベアリング仕様
ブラックナノチタンボディとセラミックベアリングを備えたI20L、 またはステンレススチールのエコノミー仕様CA2001から選択できます。

購入前に確認したいポイント

  • 使用予定のインプラントモーターとの適合性を確認する
  • 注文前に物理的なEタイプまたはインプラントモーター接続を確認する
  • モーターの回転速度・トルクコントロール範囲を確認する
  • 臨床環境に応じて光ファイバーまたは非光ファイバー仕様を選択する
  • Ø2.35 mmシャンクの対応RAラッチタイプ器具を使用する
  • 必要なドリル長とインプラントシステムとの適合性を確認する
  • 外部注水チューブと生理食塩水供給システムを確認する
  • ベアリングタイプとボディ材質を確認する
  • 清掃、注油、滅菌条件を確認する
  • 修理・交換部品の供給について確認する

適切なインプラント用コントラアングルは、 価格だけでなく、 インプラントモーター、 外科プロトコル、 照明、 注水システム、 使用する器具との適合性を考慮して選択してください。

適切な20:1 インプラント用コントラアングルの選び方

光ファイバー照明が必要な場合はModel I20L
対応するインプラントモーターが 光ファイバー伝送をサポートし、 術野の視認性を高めたい場合はI20Lを選択します。

非光ファイバーのエコノミー仕様にはModel CA2001
ハンドピースを通した光伝送を必要とせず、 ステンレススチール仕様を求める場合は CA2001を選択します。

インプラントモーターとの適合性を確認
購入前に接続方式、 回転速度範囲、 トルク設定、 注水システム、 光伝送機能を確認してください。

器具の適合性を確認
選択したハンドピースと インプラントプロトコルに対応する 標準Ø2.35 mmシャンクのRAラッチタイプバーおよび インプラントドリルを使用してください。

予定する処置を確認
オステオトミードリリング、 インプラント埋入、 スレッドタッピング、 その他の対応する外科処置に応じて選択してください。

視認性の必要性を確認
光ファイバーは臼歯部などの視認性をサポートします。 一方、診療用・外科用照明で十分な視認性を確保できる場合は、 非光ファイバー仕様も選択肢となります。

RAバー・インプラント器具の適合性

Model I20LとModel CA2001は、 標準Ø2.35 mmシャンクの RAラッチタイプバーおよび 対応するインプラント器具に対応します。

RAとCAは、 同じラッチタイプのバーシャンク形式を表す名称として 一般的に使用されます。 ただし、Ø2.35 mmの器具であれば すべてインプラント外科に使用できるわけではありません。

器具の長さ、切削形状、 許容回転数、 インプラントシステムとの適合性も 必ず確認してください。

インプラントドリルは、 使用するサージカルキットおよび インプラントメーカーが推奨する ドリリングシーケンスに従って選択してください。 一般的な修復用RAバーを 専用インプラントドリルの代わりに使用しないでください。

FG、RA、HPバーの違いについて詳しくは、 FG・RA・HPバー適合ガイド をご覧ください。

使用前には、 インプラント器具が完全に挿入され、 確実に保持されていること、 また設定した回転速度とトルクに 対応していることを確認してください。

外部注水と外科用イリゲーション

Model I20LとModel CA2001は、 1点外部注水システムを採用しています。 外部注水パイプから、 インプラントドリルと術野へ 滅菌冷却液を供給します。

効果的な注水は、 オステオトミー形成中の温度管理、 切削片の除去、 視認性をサポートします。 冷却液がドリルの作業部まで届くよう、 スプレーパイプを適切に配置してください。

処置を開始する前に、 注水チューブが確実に接続されていること、 生理食塩水が正常に流れていること、 スプレー出口が詰まっていないことを確認してください。

外部注水は、 インプラントモーターおよび インプラントシステムの指示に従って使用してください。 使用するドリルや外科プロトコルによっては、 追加の内部注水が必要となる場合があります。

光ファイバー仕様と非光ファイバー仕様

Model I20Lは光ファイバー伝送を備えています。 対応するインプラントモーターからの光を、 ハンドピースを通して術野へ伝送します。

光ファイバーによる視認性は、 臼歯部やアクセスが制限される部位での インプラントドリリングや器具位置決めをサポートします。 この機能を使用するには、 インプラントモーター側も光伝送に対応している必要があります。

Model CA2001には光ファイバー伝送がありません。 診療用ライトまたは外科用照明によって 十分な視認性を確保できる環境に適しています。

光伝送の有無によって 20:1減速機構そのものが変わるわけではありませんが、 アクセスが難しいインプラント処置での 視認性やワークフローに影響する場合があります。

インプラントモーターとの適合性

両モデルとも、 対応する電動インプラントモーターとの使用を前提として設計されています。 適合しない歯科用エアモーターに接続したり、 一般的な修復用コントラアングルとして使用したりしないでください。

インプラントモーターには、 オステオトミー形成やインプラント埋入に適した プログラム可能な回転速度・トルク設定が必要です。

購入前に、 物理的な接続方式、 注水システム、 光ファイバー対応、 モーターのコントロール範囲を確認してください。 機械的に接続できるだけでは、 すべての機能が正常に作動するとは限りません。

インプラントモーターは、 使用するドリル、 インプラント設計、 メーカーの外科プロトコルに従って設定してください。

メンテナンスと滅菌

適切なメンテナンスは、 スムーズなギア伝達、 ベアリング性能、 注水性能、 確実な器具保持を維持するために重要です。

使用後はインプラントドリルを取り外し、 ハンドピース外面を清掃し、 製品の取扱説明書に従って 外部注水システムをフラッシュしてください。

必要に応じて、 正しい接続部またはメンテナンスアダプターから注油してください。 潤滑油を内部に行き渡らせるために短時間作動させ、 滅菌前に余分なオイルを除去します。

ヘッド、ラッチシステム、 注水パイプ、 ベアリングの動きを定期的に確認してください。 騒音、振動、発熱の増加、 回転性能の低下、 器具保持力の低下が見られる場合は、 メンテナンスが必要な可能性があります。

清掃、注油、点検、滅菌、保管について詳しくは、 Kaneiko 歯科用ハンドピース メンテナンスガイド をご覧ください。

プロフェッショナル向けポイント

インプラント治療では、 ハンドピース単体ではなく、 外科システム全体の一部として選択することが重要です。 モーターとの適合性、 インプラントドリルの設計、 トルク設定、 注水方式などが臨床性能に影響します。

Model I20Lは、 光ファイバー照明、 セラミックベアリング、 ブラックナノチタンボディを組み合わせた 高機能仕様です。 Model CA2001は、 同じ20:1減速と最大2,000 rpmの基本性能を、 非光ファイバーのステンレススチール構成で提供します。

光ファイバーがないこと自体が、 インプラント用ハンドピースとして 不適切であることを意味するわけではありません。 臼歯部へのアクセス、 診療用照明、 外科ワークフローを考慮して選択してください。

すべてのインプラント処置に 共通の回転速度やトルク値を使用するべきではありません。 モーター設定は必ず、 使用するインプラントメーカーの ドリリング・埋入プロトコルに従ってください。

Kaneiko 20:1 インプラント用コントラアングルハンドピースのメリット

  • インプラント処置向けのコントロールされた20:1減速
  • 最大2,000 rpmの出力回転数に対応
  • 対応する電動インプラントモーターに接続
  • オステオトミー形成と段階的ドリリングをサポート
  • Ø2.35 mm RAラッチタイプバー・インプラント器具に対応
  • 1点外部外科注水を採用
  • 光ファイバー・非光ファイバー仕様を選択可能
  • ブラックナノチタン・ステンレススチールのボディ仕様
  • 対応するドライバーによるコントロールされたインプラント埋入をサポート
  • 異なる臨床環境に対応する2つのモデルを用意

よくあるご質問

1. 20:1 インプラント用コントラアングルハンドピースとは何ですか?
インプラントモーターの回転速度を 器具出力側で20分の1に減速する 外科用ハンドピースです。

2. Kaneiko 20:1 インプラント用ハンドピースの最大回転数はどのくらいですか?
Model I20LとModel CA2001は、 対応するインプラントモーターと設定に応じて 最大2,000 rpmで作動します。

3. どのような処置に使用しますか?
インプラントオステオトミー形成、 段階的ドリリング、 インプラントサイト形成、 対応するインプラント埋入、 一部の低速外科処置に使用します。

4. I20LとCA2001の違いは何ですか?
I20Lは光ファイバー伝送、 セラミックベアリング、 ブラックナノチタンボディを備えています。 CA2001は非光ファイバーのエコノミーモデルで、 ステンレススチールボディを採用しています。

5. どのバー・器具に対応していますか?
両モデルとも、 標準Ø2.35 mmシャンクの RAラッチタイプバーおよび 対応するインプラント器具に対応します。

6. 両モデルとも外部注水に対応していますか?
はい。 両モデルとも1点外部注水パイプを使用して、 インプラントドリルと術野へ冷却液を供給します。

7. 歯科用エアモーターで使用できますか?
対応する電動インプラントモーター向けに設計されています。 使用前にモーター接続、 回転速度、 トルクコントロール、 注水システムとの適合性を確認してください。

8. 20:1 インプラント用ハンドピースを高速クラウン形成に使用できますか?
いいえ。 クラウン形成には通常、 高速ハンドピースまたは 適切な増速電動コントラアングルを使用します。 20:1ハンドピースは、 低速のインプラント・外科ワークフロー向けです。

9. インプラント外科に光ファイバー照明は必須ですか?
すべての環境で必須ではありませんが、 臼歯部やアクセスが制限される部位での 視認性をサポートできます。 Model I20Lは光ファイバー対応、 Model CA2001は非光ファイバー仕様です。

10. インプラント用コントラアングルはどのようにメンテナンスしますか?
使用後は器具を取り外し、 外面を清掃し、 注水経路をフラッシュしてください。 指示に従って注油し、 ラッチと注水パイプを点検したうえで適切に滅菌し、 十分に乾燥させてから保管してください。