Integrated High Speed Handpiece
Explore the Kaneiko Integrated High-Speed Handpiece Series, a value-focused range designed for reliable daily dental procedures. Featuring this collection supports FG burs, high-speed cutting, effective water cooling and built-in LED illumination. Suitable for cavity preparation, crown preparation, restoration removal and improved access in posterior or surgical procedures.
Integrated High-Speed Handpiece Series
More About Integrated High-Speed Dental Handpieces
Kaneiko integrated high-speed dental handpieces combine high-speed air-turbine cutting, built-in LED illumination, multi-point water cooling and a direct M4 connection within one clinical instrument. This integrated design allows the handpiece to connect directly to compatible four-hole dental unit tubing without requiring a separate quick coupling.
Designed for use with FG friction-grip dental burs, the collection supports efficient crown preparation, cavity preparation, restorative material removal and selected surgical cutting procedures. Both models operate from 330,000 to 400,000 rpm and deliver 27 watts of cutting power, while their different head designs support distinct clinical requirements.
The series includes the Model 100 Big Head LED High-Speed Dental Handpiece for routine restorative and prosthodontic procedures, and the Model 450 45° MOS Reverse Air Surgical High-Speed Dental Handpiece for improved posterior and surgical access.
Introducing Integrated High-Speed Handpieces in Clinical Dentistry
A high-speed dental handpiece is commonly used when efficient removal of enamel, dentine or restorative material is required. In an integrated configuration, the turbine, LED illumination, water spray system and dental-unit connection are combined into a single handpiece body.
Unlike quick-coupling handpieces, an integrated M4 handpiece connects directly to compatible four-hole tubing. This can simplify installation and reduce the number of separate connection components required within the operatory.
The built-in micro-generator powers the LED light using the handpiece airflow, allowing illumination to be directed toward the treatment area without depending on a separate fibre-optic coupling. This supports clearer visibility during crown preparation, cavity preparation, restoration removal and posterior procedures.
Clinical Applications
Crown and Bridge Preparation
Supports efficient tooth reduction and margin preparation using compatible FG diamond or carbide burs.
Cavity Preparation
Provides high rotational speed for controlled access, caries removal and preparation of restorative cavities.
Restorative Material Removal
Suitable for removing composite, temporary materials and selected existing restorations with the correct FG bur.
Inlay, Onlay and Veneer Preparation
Supports controlled reduction, preparation refinement and finishing of restorative surfaces.
Posterior Surgical Access
The Model 450 45° angled head helps improve access where a conventional head may be obstructed by adjacent teeth or oral structures.
Tooth Sectioning and Root Separation
The Model 450 may be used with compatible long FG burs for selected extraction and oral surgical procedures.
Kaneiko Integrated High-Speed Handpieces: Engineered for Cutting, Cooling and Visibility
Kaneiko integrated high-speed handpieces are designed around the clinical factors that influence high-speed cutting performance: rotational stability, effective cooling, clear visibility, secure bur compatibility and practical dental-unit connection.
Key design priorities include:
- 27-watt high-speed cutting performance
- Operating speed from 330,000 to 400,000 rpm
- Built-in micro-generator LED illumination
- Ceramic bearings for smooth turbine rotation
- Multi-point water spray for cooling and debris removal
- Integrated M4 connection for compatible four-hole tubing
- FG friction-grip bur compatibility
- Clean Head and double sealing systems
These features support efficient high-speed preparation while helping clinicians maintain visibility, cooling and controlled bur movement during daily procedures.
Model 100 Big Head LED High-Speed Dental Handpiece
The Kaneiko Model 100 features a big-head turbine configuration designed for strong and consistent cutting performance. Its 27-watt output makes it suitable for routine crown preparation, cavity preparation, veneer preparation and restorative material removal.
The four-point water mist spray distributes cooling water around the bur from multiple directions, helping manage temperature and remove cutting debris. Its built-in LED light improves visibility without requiring a separate fibre-optic quick coupling.
Model 100 accepts standard FG burs with a Ø1.6 mm shank and compatible lengths from 18.0 to 25.0 mm. It is the more suitable option when routine restorative cutting and efficient tooth reduction are the main clinical priorities.
Model 450 45° MOS Reverse Air Surgical High-Speed Handpiece
The Kaneiko Model 450 features a 45° angled surgical head designed to improve access in posterior and restricted treatment areas.
Its MOS reverse-air design helps direct exhaust airflow away from the operative site, while the three-point water spray provides cooling around the working end of the bur. This configuration supports controlled cutting during compatible tooth-sectioning, root-separation and impacted-molar procedures.
Model 450 accepts FG burs with a Ø1.6 mm shank and compatible lengths from 25.0 to 28.0 mm. Long or surgical-length FG burs should be selected according to the intended procedure and the handpiece operating requirements.
Model Comparison
| Feature | Model 100 | Model 450 |
|---|---|---|
| Primary Design | Big Head | 45° Surgical Head |
| Power Output | 27 Watts | 27 Watts |
| Operating Speed | 330,000–400,000 rpm | 330,000–400,000 rpm |
| Water Spray | Four-Point Water Mist | Three-Point Water Spray |
| Airflow Design | Standard Integrated Turbine | MOS Reverse Air |
| Illumination | Built-In LED Micro-Generator | Built-In LED Micro-Generator |
| Bearing | Ceramic Bearing | Ceramic Bearing |
| Body Material | Titanium Alloy | Titanium Alloy |
| Bur Compatibility | FG Ø1.6 mm, 18.0–25.0 mm | FG Ø1.6 mm, 25.0–28.0 mm |
| Connection | Integrated M4 | Integrated M4 |
| Recommended Use | Restorative and Prosthodontic Procedures | Posterior and Compatible Surgical Procedures |
Clinical Benefits
Efficient High-Speed Cutting
Both models deliver 27 watts of power at speeds from 330,000 to 400,000 rpm for efficient use with compatible FG burs.
Built-In LED Visibility
The internal micro-generator powers the LED illumination without requiring a separate fibre-optic coupling.
Multi-Point Water Cooling
Multiple spray outlets help cool the bur and preparation surface while removing cutting debris.
Direct M4 Connection
The integrated four-hole connection simplifies attachment to compatible dental unit tubing.
Stable Turbine Rotation
Ceramic bearings support smooth high-speed rotation and controlled bur movement.
Procedure-Specific Head Options
Clinicians can choose a big-head restorative model or a 45° surgical-access model according to the intended procedure.
Buying Considerations
- Confirm that the dental unit uses a compatible M4 four-hole connection
- Select Model 100 for routine restorative and prosthodontic cutting
- Select Model 450 for posterior access and compatible surgical procedures
- Check the required FG bur length before choosing a model
- Evaluate head size and access requirements for the intended treatment area
- Confirm that the water spray channels can be maintained and cleaned properly
- Consider access to replacement turbine cartridges and maintenance components
- Follow the specified air pressure, lubrication and sterilisation instructions
An integrated handpiece should be selected according to clinical application and dental-unit compatibility rather than speed alone. Head shape, water spray coverage, bur length and airflow direction all affect how the instrument performs during treatment.
How to Choose the Right Integrated High-Speed Handpiece
Choose According to the Main Procedure
Model 100 is intended for routine crown preparation, cavity preparation and restorative cutting. Model 450 is intended for improved posterior access and compatible surgical cutting.
Check the Head Configuration
A big head supports strong turbine cutting performance, while a 45° angled head improves access in restricted posterior areas.
Confirm FG Bur Compatibility
Both models use FG burs with a Ø1.6 mm shank, but their compatible bur-length ranges differ. Review the
FG, RA and HP Bur Compatibility Guide
before selecting rotary instruments.
Verify the Dental Unit Connection
Both models use an integrated M4 connection and should be connected only to compatible four-hole dental unit tubing.
Evaluate Water Cooling
Model 100 uses a four-point water mist spray, while Model 450 uses a three-point water spray suited to its angled surgical-head configuration.
Consider Maintenance Requirements
High-speed turbine systems require regular cleaning, lubrication, spray-channel inspection and correct sterilisation to maintain smooth rotation and cooling performance.
FG Bur Compatibility
Integrated high-speed handpieces use FG friction-grip burs with a standard Ø1.6 mm shank. FG burs are designed for high-speed rotary systems and should not be interchanged with RA latch-type or HP straight-handpiece burs.
Model 100 accepts compatible FG burs from 18.0 to 25.0 mm in length, while Model 450 accepts compatible FG burs from 25.0 to 28.0 mm. The selected bur must also be suitable for the intended operating speed, head design and clinical procedure.
Always check that the bur is fully seated and securely retained before operating the handpiece. A bent, damaged or incorrectly fitted bur may increase vibration, heat and chuck wear.
Integrated M4 Connection
Model 100 and Model 450 connect directly to compatible M4 four-hole dental unit tubing. Because the connection is integrated into the handpiece, a separate quick coupling is not required.
Before ordering, verify the dental-unit tubing configuration. An incompatible connection can affect airflow, water delivery, LED operation and turbine performance.
Maintenance and Sterilisation
Proper handpiece care supports turbine stability, water spray performance and long-term bearing reliability. After use, remove external debris, flush the air and water lines, lubricate the handpiece through the correct drive-air port and inspect the bur chuck before sterilisation.
Blocked water channels, insufficient lubrication, incorrect air pressure or worn bearings may contribute to reduced cutting efficiency, vibration, noise or overheating.
Read the Kaneiko Dental Handpiece Maintenance Guide for cleaning, lubrication, inspection, sterilisation and storage guidance.
Professional Insight
In clinical practice, integrated high-speed handpieces are useful when a straightforward M4 connection and built-in LED illumination are preferred. They reduce dependence on a separate quick coupling while maintaining the speed, water cooling and visibility required for high-speed procedures.
Model selection should begin with access and procedure type. The Model 100 is better suited to routine restorative workloads where cutting efficiency is the main priority. The Model 450 is more appropriate when a 45° head and controlled exhaust direction improve access during compatible posterior or surgical procedures.
A high-speed handpiece should not be assessed by maximum rpm alone. Cutting power, head dimensions, spray coverage, bur compatibility, airflow design and maintenance quality all influence real clinical performance.
Benefits of Using Kaneiko Integrated High-Speed Handpieces
- Support efficient crown, cavity and restorative preparation
- Provide built-in LED illumination without a separate fibre-optic coupling
- Deliver multi-point water cooling around compatible FG burs
- Connect directly to compatible M4 dental unit tubing
- Offer restorative and 45° surgical-head configurations
- Support smooth turbine rotation with ceramic bearings
- Improve posterior visibility and instrument positioning
- Simplify equipment selection for compatible four-hole dental units
Frequently Asked Questions
1. What is an integrated high-speed dental handpiece?
It is a high-speed air-turbine handpiece with a direct dental-unit connection and integrated features such as LED illumination and water spray. A separate quick coupling is not required for these M4 models.
2. What is the difference between Model 100 and Model 450?
Model 100 has a big-head configuration for routine restorative and prosthodontic cutting. Model 450 has a 45° surgical head and MOS reverse-air design for improved posterior and compatible surgical access.
3. What burs are used with Kaneiko integrated high-speed handpieces?
Both models use FG friction-grip burs with a standard Ø1.6 mm shank.
4. What bur length is compatible with Model 100?
Model 100 accepts compatible FG burs approximately 18.0 to 25.0 mm in length.
5. What bur length is compatible with Model 450?
Model 450 accepts compatible FG burs approximately 25.0 to 28.0 mm in length, including suitable long or surgical-length FG burs.
6. Do these handpieces require a quick coupling?
No. Both models have an integrated M4 connection and connect directly to compatible four-hole dental unit tubing.
7. How is the LED light powered?
The LED light is powered by a built-in micro-generator that uses the handpiece airflow to provide illumination.
8. Is Model 450 suitable for routine crown preparation?
It may perform high-speed cutting with compatible FG burs, but its 45° head is primarily designed for posterior and compatible surgical access. Model 100 is generally the more direct choice for routine restorative preparation.
9. What does MOS reverse air mean?
The Model 450 MOS reverse-air design helps direct exhaust airflow away from the operative site instead of toward the surgical working area.
10. How should integrated high-speed handpieces be maintained?
Clean the exterior after use, flush the internal lines, lubricate through the correct port, inspect the chuck and spray outlets, sterilise according to the product instructions and store the handpiece completely dry.
一体型高速ハンドピースシリーズ
一体型高速歯科用ハンドピースについて
Kaneiko 一体型高速歯科用ハンドピース は、高速エアタービンによる切削性能、内蔵LED照明、多点注水冷却、 M4ダイレクト接続を1本の臨床用ハンドピースに統合しています。 この一体型設計により、別体のクイックカップリングを使用せず、 対応する4ホール歯科ユニットチューブへ直接接続できます。
FG(フリクショングリップ)歯科用バーに対応し、 クラウン形成、窩洞形成、修復材料の除去、 および一部の外科的切削処置をサポートします。 両モデルとも330,000~400,000 rpmで作動し、 27Wの切削出力を備えています。 また、それぞれ異なるヘッド設計により、 異なる臨床ニーズに対応します。
本シリーズには、日常的な修復・補綴処置に適した Model 100 ビッグヘッド LED 高速歯科用ハンドピース と、臼歯部および外科処置でのアクセス性を高める Model 450 45° MOS リバースエア 外科用高速歯科用ハンドピース があります。
臨床歯科における一体型高速ハンドピース
高速歯科用ハンドピースは、エナメル質、象牙質、 または修復材料を効率的に除去する必要がある処置で一般的に使用されます。 一体型構造では、タービン、LED照明、注水スプレーシステム、 歯科ユニット接続部が1本のハンドピース本体に統合されています。
クイックカップリング式ハンドピースとは異なり、 一体型M4ハンドピースは対応する4ホールチューブへ直接接続します。 これにより、接続をシンプルにし、 診療環境で必要となる個別の接続部品を減らすことができます。
内蔵マイクロジェネレーターはハンドピースのエアフローを利用してLEDを発光させるため、 別体の光ファイバーカップリングを必要とせず、 治療部位を照らすことができます。 クラウン形成、窩洞形成、修復物除去、 臼歯部での処置における視認性をサポートします。
主な臨床用途
クラウン・ブリッジ形成
対応するFGダイヤモンドバーまたはカーバイドバーを使用し、
効率的な歯質削合とマージン形成をサポートします。
窩洞形成
高速回転により、アクセス形成、う蝕除去、
修復窩洞の形成をコントロールしながら行えます。
修復材料の除去
適切なFGバーを使用することで、コンポジットレジン、
暫間材料、および一部の既存修復物の除去に対応します。
インレー・オンレー・ベニア形成
修復面のコントロールされた削合、形成の調整、
仕上げをサポートします。
臼歯部の外科的アクセス
Model 450の45°アングルヘッドは、
従来型ヘッドでは隣在歯や口腔内組織が干渉しやすい部位での
アクセス性を高めます。
歯冠分割・歯根分割
Model 450は、対応するロングFGバーと組み合わせることで、
一部の抜歯および口腔外科処置に使用できます。
Kaneiko 一体型高速ハンドピース:切削・冷却・視認性を追求した設計
Kaneiko 一体型高速ハンドピース は、高速切削性能に影響する臨床的要素である 回転安定性、効果的な冷却、良好な視認性、 確実なバー適合性、実用的な歯科ユニット接続を考慮して設計されています。
主な設計ポイント:
- 27Wの高速切削性能
- 330,000~400,000 rpmの作動回転数
- 内蔵マイクロジェネレーター式LED照明
- スムーズなタービン回転を支えるセラミックベアリング
- 冷却と切削片除去をサポートする多点注水スプレー
- 対応する4ホールチューブ用一体型M4接続
- FGフリクショングリップバー対応
- クリーンヘッドおよびダブルシーリングシステム
これらの機能により、日常の高速切削処置において、 視認性、冷却性能、バーの安定した操作を維持しながら、 効率的な形成をサポートします。
Model 100 ビッグヘッド LED 高速歯科用ハンドピース
Kaneiko Model 100 は、強力で安定した切削性能を目的とした ビッグヘッドタービン構造を採用しています。 27Wの出力により、日常的なクラウン形成、窩洞形成、 ベニア形成、修復材料の除去に適しています。
4点ウォーターミストスプレーがバー周囲へ多方向から冷却水を供給し、 温度管理と切削片の除去をサポートします。 内蔵LEDにより、別体の光ファイバークイックカップリングを使用せずに 治療部位の視認性を高めます。
Model 100は、標準Ø1.6 mmシャンク、 長さ18.0~25.0 mmの対応FGバーを使用できます。 日常的な修復切削と効率的な歯質削合を主な目的とする場合に適したモデルです。
Model 450 45° MOS リバースエア 外科用高速ハンドピース
Kaneiko Model 450 は、臼歯部やアクセスが制限される治療部位へのアクセス性を高めるため、 45°アングル外科用ヘッドを採用しています。
MOSリバースエア設計は、排気を術野から遠ざける方向へ導くことを目的としています。 また、3点注水スプレーがバー作業部周囲を冷却します。 この構成により、対応する歯冠分割、歯根分割、 埋伏臼歯処置などでのコントロールされた切削をサポートします。
Model 450は、Ø1.6 mmシャンク、 長さ25.0~28.0 mmの対応FGバーを使用できます。 ロングFGバーまたは外科用ロングFGバーは、 処置内容およびハンドピースの使用条件に合わせて選択してください。
Model 100・Model 450 比較
| 項目 | Model 100 | Model 450 |
|---|---|---|
| 主な設計 | ビッグヘッド | 45° 外科用ヘッド |
| 出力 | 27W | 27W |
| 作動回転数 | 330,000~400,000 rpm | 330,000~400,000 rpm |
| 注水スプレー | 4点ウォーターミスト | 3点注水スプレー |
| エアフロー設計 | 標準一体型タービン | MOS リバースエア |
| 照明 | 内蔵LEDマイクロジェネレーター | 内蔵LEDマイクロジェネレーター |
| ベアリング | セラミックベアリング | セラミックベアリング |
| ボディ材質 | チタン合金 | チタン合金 |
| 対応バー | FG Ø1.6 mm、18.0~25.0 mm | FG Ø1.6 mm、25.0~28.0 mm |
| 接続方式 | 一体型M4 | 一体型M4 |
| 推奨用途 | 修復・補綴処置 | 臼歯部および対応する外科処置 |
臨床上のメリット
効率的な高速切削
両モデルとも330,000~400,000 rpmで27Wの出力を備え、
対応するFGバーを使用した効率的な高速切削をサポートします。
内蔵LEDによる視認性
内蔵マイクロジェネレーターがLED照明へ電力を供給するため、
別体の光ファイバーカップリングを必要としません。
多点注水冷却
複数のスプレー孔からバーおよび形成面へ注水し、
冷却と切削片の除去をサポートします。
M4ダイレクト接続
一体型4ホール接続により、
対応する歯科ユニットチューブへ直接接続できます。
安定したタービン回転
セラミックベアリングがスムーズな高速回転と
コントロールされたバー操作をサポートします。
処置に応じたヘッド選択
日常的な修復処置向けのビッグヘッドモデルと、
外科的アクセスを考慮した45°ヘッドモデルから選択できます。
購入前に確認したいポイント
- 歯科ユニットが対応するM4 4ホール接続を使用しているか確認する
- 日常的な修復・補綴切削にはModel 100を検討する
- 臼歯部へのアクセスや対応する外科処置にはModel 450を検討する
- モデル選択前に必要なFGバーの長さを確認する
- 治療部位に必要なヘッドサイズとアクセス性を確認する
- 注水スプレー経路を適切に清掃・管理できることを確認する
- 交換用タービンカートリッジやメンテナンス部品の入手性を確認する
- 指定されたエア圧、注油、滅菌方法に従う
一体型ハンドピースは、回転数だけではなく、 臨床用途と歯科ユニットとの適合性に基づいて選択する必要があります。 ヘッド形状、注水範囲、バーの長さ、排気方向も、 治療中のハンドピース性能に影響します。
適切な一体型高速ハンドピースの選び方
主な処置に合わせて選択する
Model 100は、日常的なクラウン形成、窩洞形成、
修復切削を目的としています。
Model 450は、臼歯部へのアクセス性と、
対応する外科的切削を考慮したモデルです。
ヘッド構造を確認する
ビッグヘッドは強力なタービン切削性能をサポートし、
45°アングルヘッドはアクセスが制限される臼歯部での操作性を高めます。
FGバーの適合性を確認する
両モデルともØ1.6 mmシャンクのFGバーを使用しますが、
対応するバーの長さが異なります。
回転器具を選択する前に、
FG・RA・HPバー適合ガイド
をご確認ください。
歯科ユニットとの接続を確認する
両モデルとも一体型M4接続を採用しているため、
対応する4ホール歯科ユニットチューブにのみ接続してください。
注水冷却を確認する
Model 100は4点ウォーターミストスプレー、
Model 450は45°外科用ヘッド構造に合わせた
3点注水スプレーを採用しています。
メンテナンス要件を確認する
高速タービンシステムでは、スムーズな回転と冷却性能を維持するため、
定期的な清掃、注油、スプレー経路の点検、
適切な滅菌が必要です。
FGバーの適合性
一体型高速ハンドピースでは、 標準Ø1.6 mmシャンクのFG(フリクショングリップ)バーを使用します。 FGバーは高速回転システム用に設計されており、 RAラッチタイプバーやHPストレートハンドピース用バーとは 互換使用しないでください。
Model 100は長さ18.0~25.0 mmの対応FGバー、 Model 450は長さ25.0~28.0 mmの対応FGバーを使用できます。 使用するバーは、想定される回転数、ヘッド設計、 臨床処置にも適合している必要があります。
ハンドピースを作動させる前に、 バーが奥まで正しく挿入され、確実に保持されていることを確認してください。 曲がったバー、損傷したバー、正しく装着されていないバーは、 振動、発熱、チャック摩耗の増加につながる可能性があります。
一体型M4接続
Model 100とModel 450は、 対応するM4 4ホール歯科ユニットチューブへ直接接続します。 接続部がハンドピース本体に一体化されているため、 別体のクイックカップリングは必要ありません。
ご注文前に、使用する歯科ユニットのチューブ構成をご確認ください。 接続方式が適合していない場合、 エアフロー、注水、LED作動、タービン性能に影響する可能性があります。
メンテナンスと滅菌
適切なハンドピースメンテナンスは、 タービンの安定性、注水性能、 ベアリングの長期的な信頼性を維持するために重要です。 使用後は外部の汚れを除去し、エア・水経路をフラッシュし、 適切なドライブエアポートから注油を行い、 滅菌前にバーチャックを点検してください。
注水経路の詰まり、不十分な注油、不適切なエア圧、 ベアリングの摩耗などは、 切削効率の低下、振動、騒音、発熱につながる可能性があります。
清掃、注油、点検、滅菌、保管について詳しくは、 Kaneiko 歯科用ハンドピース メンテナンスガイド をご覧ください。
プロフェッショナル向けポイント
臨床現場では、シンプルなM4接続と内蔵LED照明を重視する場合、 一体型高速ハンドピースが実用的な選択肢となります。 別体のクイックカップリングへの依存を減らしながら、 高速処置に必要な回転速度、注水冷却、視認性を提供します。
モデル選択では、まずアクセス性と処置内容を確認することが重要です。 Model 100は、切削効率を重視する日常的な修復処置に適しています。 Model 450は、45°ヘッドと排気方向のコントロールが、 対応する臼歯部または外科処置でのアクセス性向上に役立つ場合に適しています。
高速ハンドピースは最大回転数だけで評価するべきではありません。 切削出力、ヘッド寸法、注水範囲、バー適合性、 エアフロー設計、メンテナンス状態も、 実際の臨床性能に影響します。
Kaneiko 一体型高速ハンドピースのメリット
- 効率的なクラウン形成、窩洞形成、修復形成をサポート
- 別体の光ファイバーカップリングを必要としない内蔵LED照明
- 対応FGバー周囲への多点注水冷却
- 対応するM4歯科ユニットチューブへ直接接続
- 修復用ビッグヘッドと45°外科用ヘッドをラインアップ
- セラミックベアリングによるスムーズなタービン回転
- 臼歯部での視認性と器具ポジショニングをサポート
- 対応する4ホール歯科ユニットでの機器構成をシンプルに
よくあるご質問
1. 一体型高速歯科用ハンドピースとは何ですか?
歯科ユニットへのダイレクト接続と、
LED照明や注水スプレーなどの機能を一体化した
高速エアタービンハンドピースです。
これらのM4モデルでは、別体のクイックカップリングは必要ありません。
2. Model 100とModel 450の違いは何ですか?
Model 100は、日常的な修復・補綴切削に適したビッグヘッド構造です。
Model 450は、臼歯部および対応する外科処置へのアクセス性を高める
45°外科用ヘッドとMOSリバースエア設計を採用しています。
3. Kaneiko 一体型高速ハンドピースではどのバーを使用しますか?
両モデルとも標準Ø1.6 mmシャンクの
FG(フリクショングリップ)バーを使用します。
4. Model 100に対応するバーの長さは?
Model 100は、約18.0~25.0 mmの対応FGバーを使用できます。
5. Model 450に対応するバーの長さは?
Model 450は、約25.0~28.0 mmの対応FGバーを使用できます。
適切なロングFGバーまたは外科用ロングFGバーにも対応します。
6. クイックカップリングは必要ですか?
いいえ。両モデルとも一体型M4接続を採用しており、
対応する4ホール歯科ユニットチューブへ直接接続します。
7. LEDライトはどのように発光しますか?
内蔵マイクロジェネレーターがハンドピースのエアフローを利用して
LED照明へ電力を供給します。
8. Model 450は通常のクラウン形成にも使用できますか?
対応するFGバーを使用した高速切削は可能ですが、
45°ヘッドは主に臼歯部および対応する外科処置でのアクセス性を考慮した設計です。
日常的な修復形成にはModel 100がより直接的な選択肢となります。
9. MOSリバースエアとは何ですか?
Model 450のMOSリバースエア設計は、
排気を外科的作業部位へ向けるのではなく、
術野から遠ざける方向へ導くことを目的としています。
10. 一体型高速ハンドピースはどのようにメンテナンスしますか?
使用後に外面を清掃し、内部ラインをフラッシュし、
適切なポートから注油します。
チャックとスプレー孔を点検し、
製品の取扱説明書に従って滅菌した後、
完全に乾燥させて保管してください。