Low-Speed Handpiece

Explore the KANEIKO Low-Speed Handpiece collection. This page includes contra angle handpieces, straight handpieces, and surgical low-speed handpieces designed for precise cutting and polishing procedures. Suitable for caries removal, polishing, finishing, and surgical applications, these handpieces provide smooth operation, stable torque, and reliable durability for daily clinical use.

Skip to results list
4 items
Column grid
Column grid

Filter

Low-Speed Handpiece Series

More About Low-Speed Dental Handpieces

Kaneiko low-speed dental handpieces are designed for controlled rotation, precise instrument handling and versatile performance during restorative, finishing and selected surgical procedures.

This collection includes 1:1 low-speed contra-angle handpieces, 1:1 surgical contra-angle handpieces, straight low-speed handpieces and surgical straight handpieces. Each configuration provides a different working-head design and instrument system to support specific clinical applications.

Contra-angle handpieces are commonly used for intraoral caries removal, composite finishing and restorative adjustment with compatible RA latch-type burs. Straight handpieces use compatible HP-shank instruments and are especially useful for denture adjustment, extraoral finishing and selected surgical procedures.

These handpieces operate with suitable dental air motors. The appropriate configuration should be selected according to the intended procedure, motor compatibility, bur type, irrigation requirements and working-area accessibility.

Introducing Low-Speed Handpieces in Clinical Dentistry

A low-speed dental handpiece is a rotary instrument powered by a compatible dental motor. Unlike an air-turbine high-speed handpiece, a low-speed system is typically selected for procedures requiring controlled rotation, suitable torque and accurate instrument movement.

Low-speed attachments are available in two principal configurations: contra-angle handpieces and straight handpieces.

Contra-angle attachments feature an angled head that improves access to posterior teeth and confined intraoral areas. Straight handpieces maintain a linear working configuration and are commonly used for extraoral laboratory work, denture adjustment and compatible surgical procedures.

The 1:1 direct-drive contra-angle transmits motor speed without increasing or reducing the rotational ratio. Straight low-speed handpieces similarly operate according to their specified transmission mechanism and motor input.

The clinical performance of a low-speed handpiece depends on motor stability, instrument retention, rotational control, irrigation and the condition of the cutting or polishing instrument.

What Are Low-Speed Dental Handpieces Used For?

Controlled Caries Removal
A 1:1 contra-angle supports low-speed removal of affected dentine using suitable RA round or pear-shaped burs.

Composite Finishing and Adjustment
Compatible contra-angle attachments support contouring, smoothing, occlusal adjustment and finishing of composite restorations.

Restoration Margin Refinement
Controlled low-speed rotation helps refine restoration margins using suitable finishing instruments.

Denture Adjustment
Straight low-speed handpieces can be used with compatible HP burs and abrasive instruments for trimming and adjusting acrylic denture materials.

Denture Finishing and Polishing
Straight handpieces support extraoral smoothing, surface refinement and polishing with suitable dental laboratory instruments.

Temporary Restoration Adjustment
Low-speed handpieces can assist with shaping and refining temporary restorative materials using compatible instruments.

Selected Oral Surgical Procedures
Surgical contra-angle and surgical straight handpieces support approved low-speed surgical cutting and trimming procedures when used with suitable surgical instruments and irrigation.

Extraoral Prosthetic Adjustments
Straight handpieces provide practical handling for adjustments to dentures and selected prosthetic materials outside the mouth.

Kaneiko Low-Speed Handpieces: Designed for Controlled Rotation and Handling

Kaneiko low-speed handpieces offer different attachment configurations to support restorative and surgical procedures where controlled instrument movement is required.

Key design considerations include:

  • Direct-drive 1:1 transmission for compatible contra-angle models
  • Controlled low-speed rotation for restorative finishing
  • Angled head configuration for intraoral access
  • Straight-body design for compatible HP instruments
  • Restorative and surgical configurations
  • RA latch-type bur compatibility for appropriate contra-angle models
  • HP bur compatibility for appropriate straight handpiece models
  • Model-specific internal or external irrigation arrangements
  • Fibre-optic and non-optic configurations where available
  • Compatibility with suitable dental air motors

The choice between straight and contra-angle attachments should be based on instrument compatibility, working position and the requirements of the clinical procedure.

Low-Speed Handpiece Model Comparison

Feature 1:1 Contra-Angle 1:1 Surgical Contra-Angle Straight Low-Speed Surgical Straight
Handpiece Type Restorative Contra-Angle Surgical Contra-Angle General Straight Surgical Straight
Head Design Angled Head Angled Surgical Head Straight Body Straight Surgical Body
Transmission 1:1 Direct Drive 1:1 Direct Drive Model-Specific Model-Specific
Operating Movement Continuous Rotation Continuous Rotation Continuous Rotation Continuous Rotation
Bur Compatibility RA / CA Burs Compatible RA Surgical Instruments HP-Shank Instruments Approved Surgical Instruments
Irrigation Internal Water Spray External Water Spray According to Model According to Model
Main Application Caries Removal and Finishing Selected Surgical Trimming Denture Adjustment and Polishing Selected Oral Surgery
Motor Compatibility Compatible Dental Air Motor Compatible Dental Air Motor Compatible Dental Air Motor Compatible Dental Air Motor

Exact rotational speeds, irrigation configurations and instrument dimensions must be confirmed against the selected model's specifications.

1:1 Low-Speed Contra-Angle Handpiece

The Kaneiko 1:1 Contra Angle Low Speed Dental Handpiece is designed for routine restorative, finishing and chairside dental procedures.

Its 1:1 direct-drive mechanism transfers motor speed to the bur without increasing or reducing the rotational ratio. Depending on the motor and model specifications, compatible versions can operate at up to 40,000 rpm.

The angled head improves access to posterior teeth and confined areas. Compatible RA latch-type burs can be used for controlled caries removal, composite refinement, polishing and restorative adjustments.

Model C offers fibre-optic light transmission, while Model C100 provides a non-optic configuration. Both use internal water spray and accept compatible 2.35 mm RA latch-type burs.

1:1 Surgical Low-Speed Contra-Angle Handpiece

The Kaneiko 1:1 Surgical Low-Speed Contra-Angle Handpiece provides controlled rotation for selected compatible surgical cutting and trimming procedures.

Its angled head allows suitable access to confined intraoral surgical areas. The 1:1 transmission maintains motor input speed for controlled instrument movement.

The surgical design includes an external water spray configuration to direct irrigation toward the working instrument during approved procedures.

Model CX provides fibre-optic light transmission, while Model CX100 is non-optic. Instrument compatibility and approved surgical use should be checked before treatment.

Straight Low-Speed Dental Handpiece

Kaneiko straight low-speed dental handpieces feature a straight working configuration designed for compatible HP-shank cutting, finishing and polishing instruments.

The straight design is especially useful during extraoral adjustments, dental laboratory procedures and denture finishing, where a linear instrument position provides practical access to the workpiece.

These handpieces can support adjustment of acrylic dentures, smoothing of prosthetic materials and polishing workflows when used with approved instruments at the appropriate rotational speed.

Confirm the instrument shank dimensions, rated operating speed and motor connection before use. Straight handpieces should not be confused with RA latch-type contra-angle attachments.

Surgical Straight Low-Speed Dental Handpiece

Kaneiko surgical straight low-speed dental handpieces are designed for selected oral surgical procedures requiring a straight working instrument and controlled motor-driven rotation.

Their linear design can provide a suitable working approach during approved surgical trimming and cutting procedures using compatible surgical instruments.

Surgical use requires verification of instrument retention, rotational speed, irrigation arrangements and compatibility with the selected motor system.

A surgical straight handpiece is not automatically interchangeable with a general straight handpiece. The manufacturer's approved applications and operating requirements should guide instrument selection.

Clinical Benefits

Controlled Low-Speed Performance
Low-speed attachments provide suitable rotational control for finishing, adjustment and compatible surgical applications.

Different Working Configurations
Contra-angle and straight handpieces allow clinicians to choose a working position suited to the procedure.

Improved Intraoral Access
Contra-angle heads support access to posterior teeth and confined intraoral areas.

Practical Extraoral Handling
Straight handpieces support denture adjustment and polishing with compatible HP instruments.

Dedicated Surgical Options
Surgical contra-angle and surgical straight configurations support selected approved oral surgical applications.

Instrument-Specific Compatibility
Suitable RA, HP and surgical instruments can be selected according to the handpiece configuration.

Buying Considerations

  • Identify whether a contra-angle or straight attachment is required
  • Confirm intended restorative, extraoral or surgical use
  • Check compatibility with the dental air motor
  • Verify the permitted input and output speed
  • Confirm RA, HP or approved surgical instrument compatibility
  • Choose internal or external water spray where applicable
  • Consider fibre-optic illumination requirements
  • Check bur retention and shank dimensions
  • Review cleaning, lubrication and sterilisation instructions
  • Confirm maintenance and replacement support

The best low-speed handpiece depends on the intended procedure, compatible instrument type and working position rather than rotational speed alone.

How to Choose the Right Low-Speed Dental Handpiece

For Caries Removal and Restorative Finishing
Choose a 1:1 contra-angle with compatible RA burs for controlled intraoral procedures.

For Selected Intraoral Surgical Trimming
Choose a suitable 1:1 surgical contra-angle when an angled head and external irrigation are required.

For Denture Adjustment
Choose a straight low-speed handpiece with compatible HP cutting or abrasive instruments.

For Denture Finishing and Polishing
A straight handpiece provides a practical configuration for compatible extraoral finishing and polishing instruments.

For Selected Surgical Procedures
Choose a surgical straight handpiece when its approved instrument system and straight working configuration are appropriate.

RA and HP Bur Compatibility

Low-speed dental handpieces do not all use the same burs. Instrument compatibility depends on the handpiece's retention mechanism, shank dimensions and operating speed.

RA / CA Latch-Type Burs
Compatible 1:1 contra-angle handpieces typically use RA latch-type burs with a standard 2.35 mm shank and latch-retention groove.

HP Straight-Handpiece Burs
Straight handpieces use compatible HP-shank instruments, commonly featuring a 2.35 mm shank without the RA latch groove.

Surgical Instruments
Surgical models require instruments specifically approved for the selected handpiece, retention system and procedure.

RA burs, HP burs and FG burs should not be treated as interchangeable simply because some share similar shaft dimensions.

Read the FG, RA and HP Bur Compatibility Guide for Dental Handpieces for further information.

Internal vs External Water Spray

Water spray configurations vary according to handpiece design and clinical application.

Internal Water Spray
Selected 1:1 restorative contra-angle handpieces deliver cooling water through internal channels toward the working instrument.

External Water Spray
Selected surgical contra-angle models use external irrigation to direct cooling water toward the operative area.

Straight Handpieces
Cooling requirements depend on the selected straight model, cutting instrument and whether the procedure is extraoral or surgical.

During surgical cutting, follow the appropriate irrigation instructions and confirm adequate cooling at the working area.

Fibre-Optic and Non-Optic Options

Selected low-speed contra-angle models are available with fibre-optic light transmission, which can support visibility during intraoral treatment.

Fibre-optic configurations require compatible light-transmitting motor systems. Non-optic models are suitable when external operatory illumination is sufficient.

Check the selected model's illumination capabilities and motor compatibility before purchasing.

Dental Air Motor Compatibility

Kaneiko low-speed contra-angle and straight handpieces are designed for use with compatible dental air motors, subject to their individual connection and operating specifications.

1:1 Contra-Angle Handpieces
Compatible dental air motors provide direct rotational input for restorative and finishing procedures.

1:1 Surgical Contra-Angle Handpieces
Compatible motor systems provide controlled rotation for approved surgical applications.

Straight Low-Speed Handpieces
Suitable dental air motors can drive compatible straight handpieces for finishing, polishing and adjustment procedures.

Surgical Straight Handpieces
Compatible motor connections may provide rotational input for approved surgical use, subject to speed, irrigation and instrument requirements.

Always confirm the mechanical connection, maximum operating speed and intended clinical use. A compatible attachment alone does not establish suitability for every surgical procedure.

Maintenance and Sterilisation

Proper maintenance helps preserve rotational performance, instrument retention and reliable operation of low-speed handpieces.

After treatment, remove the cutting or polishing instrument, clean the exterior and inspect the working head and water pathway where applicable.

Lubricate through the appropriate port when required and follow the manufacturer's instructions for lubricant type and frequency.

Unusual noise, vibration, overheating or reduced rotation may indicate the need for cleaning, lubrication or professional servicing.

Sterilise the handpiece according to its approved temperature, cycle and drying requirements.

Read the Kaneiko Dental Handpiece Maintenance Guide for additional guidance.

Professional Insight

Low-speed handpieces should be selected according to instrument geometry and the clinical working area rather than speed alone.

A 1:1 contra-angle is suitable for controlled intraoral caries removal and restorative finishing. A straight handpiece is more appropriate for compatible extraoral denture adjustment and laboratory-style finishing procedures.

Surgical variants have separate indications and irrigation requirements. Their approved applications should be confirmed before use.

Proper bur selection, motor compatibility, cooling and maintenance remain essential for predictable clinical performance.

Benefits of Using Kaneiko Low-Speed Dental Handpieces

  • Provide controlled rotation for restorative and finishing procedures
  • Offer contra-angle and straight working configurations
  • Support caries removal with compatible RA burs
  • Support composite finishing and restorative adjustment
  • Enable denture adjustment with compatible HP instruments
  • Support extraoral polishing and finishing procedures
  • Offer selected surgical contra-angle and straight configurations
  • Provide model-specific irrigation options
  • Offer fibre-optic options on selected models
  • Support compatible dental air motor connections

Frequently Asked Questions

1. What is a low-speed dental handpiece?
A low-speed handpiece is a motor-driven dental rotary instrument used for controlled cutting, finishing, polishing and selected surgical procedures.

2. What is the difference between a contra-angle and a straight handpiece?
A contra-angle has an angled working head suited to intraoral access, while a straight handpiece has a linear configuration often used for extraoral adjustment and compatible surgical procedures.

3. What is a 1:1 contra-angle used for?
It is used for controlled caries removal, composite finishing, restoration margin refinement and other suitable low-speed procedures.

4. What burs are used with 1:1 contra-angle handpieces?
Compatible models typically use RA latch-type burs with a standard 2.35 mm shank.

5. What is a straight low-speed handpiece used for?
It is commonly used for denture adjustment, extraoral finishing, polishing and compatible laboratory procedures.

6. What instruments are compatible with straight handpieces?
Straight handpieces typically use compatible HP-shank burs and polishing instruments, subject to the model specifications.

7. Can a low-speed handpiece be used for crown preparation?
Low-speed attachments can support selected finishing tasks, but major crown preparation generally requires an appropriate high-speed cutting system.

8. Are surgical low-speed handpieces different from general models?
Yes. Surgical configurations may have different working designs, irrigation systems and approved instrument requirements.

9. Can all Kaneiko low-speed handpieces connect to dental air motors?
The collection includes models designed for compatible dental air motors. Connection and operating requirements vary by model.

10. Can RA burs be used in straight handpieces?
Not unless the manufacturer specifically approves that instrument system. Straight handpieces generally use HP-shank instruments rather than RA latch-type burs.

11. Do low-speed handpieces require water cooling?
Cooling requirements depend on the procedure and model. Surgical cutting and other heat-generating procedures may require suitable irrigation.

12. How should low-speed dental handpieces be maintained?
Clean, inspect, lubricate when required and sterilise the handpiece according to its product instructions.

低速歯科用ハンドピースシリーズ

低速歯科用ハンドピースについて

Kaneikoの 低速歯科用ハンドピース は、安定した回転伝達と操作性を重視し、保存修復処置、研磨・仕上げ、義歯調整、適応する口腔外科処置などに使用する歯科用器具です。

本シリーズには、 等速1:1コントラアングル、外科用等速1:1コントラアングル、低速ストレートハンドピース、外科用ストレートハンドピース の4種類をラインアップしています。

コントラアングルタイプは、適合するRAバーを使用したう蝕除去やコンポジットレジン修復物の仕上げなど、主に口腔内での処置に使用します。 ストレートタイプは、適合するHPバーや研磨器具を使用した義歯調整、口腔外での仕上げ、用途に応じた外科処置などに適しています。

各モデルは、接続規格と使用条件に適合する歯科用エアモーターと組み合わせて使用します。 処置内容、バーの種類、使用回転数、注水方式、作業部位へのアクセス性に応じた機種選択が重要です。

歯科診療における低速ハンドピースの役割

低速歯科用ハンドピースは、適合する歯科用モーターから回転動力を受け、比較的低い回転数で切削、仕上げ、研磨などを行う器具です。

エアタービンによる高速切削とは異なり、低速ハンドピースは回転操作のコントロールや、用途に応じたトルク特性が求められる処置で使用されます。

主な形状にはコントラアングルタイプとストレートタイプがあります。

コントラアングルはヘッドに角度があるため、臼歯部など口腔内の狭い領域へのアクセスに適しています。 ストレートハンドピースは切削器具を本体と同じ方向に保持し、義歯調整や口腔外での研磨作業などに使用されます。

等速1:1タイプは、モーターの入力回転数を増減速せずに伝達します。 一方、ストレートハンドピースの伝達方式や許容回転数については、各機種の仕様を確認する必要があります。

低速歯科用ハンドピースの主な用途

う蝕除去
等速1:1コントラアングルと適合するRAタイプのラウンドバーなどを使用し、う蝕象牙質の除去を低速でコントロールしながら行います。

コンポジットレジン修復物の仕上げ
適合するコントラアングル用バーを使用し、修復物の形態修正、表面の平滑化、咬合調整などを行います。

修復物辺縁部の調整
適切な仕上げ用器具と低速回転により、修復物辺縁部の形態を調整します。

義歯調整
ストレートハンドピースと適合するHPバーや研削器具を使用し、義歯床用レジンなどの削合・形態修正を行います。

義歯の仕上げ・研磨
ストレートハンドピースは、適合する研磨器具を使用した義歯の口腔外研磨や表面仕上げに適しています。

暫間修復物の調整
低速ハンドピースと適切な器具を使用し、暫間補綴物や修復材料の形態調整に対応します。

口腔外科処置
外科用コントラアングルおよび外科用ストレートハンドピースは、指定された外科用器具や注水方式を使用し、承認された低速外科切削・形態修正などに対応します。

口腔外での補綴物調整
ストレートハンドピースは、適合する器具を用いた義歯や一部補綴材料の口腔外調整に使用できます。

Kaneiko低速ハンドピースの設計上の特長

Kaneikoの 低速歯科用ハンドピースシリーズ は、口腔内での保存修復処置から口腔外での義歯調整、適応する外科処置まで、用途に応じた形状と器具保持方式を提供します。

主な特長と選択ポイントは以下のとおりです。

  • 等速1:1コントラアングルによる低速回転
  • う蝕除去や修復物の仕上げに適した操作性
  • 口腔内へのアクセスを考慮したアングルヘッド
  • HPシャンク器具に対応するストレート形状
  • 一般診療用と外科用の各モデルを用意
  • 適合するRAラッチ式バーへの対応
  • ストレートタイプでの適合するHPバー使用
  • 機種に応じた内部・外部注水方式
  • 一部モデルに光伝達機能を用意
  • 適合する歯科用エアモーターに対応

処置部位、使用するバー、作業角度、モーター性能を考慮し、適切な形状と機種を選択してください。

低速ハンドピースのモデル比較

比較項目 1:1コントラアングル 外科用1:1コントラアングル 低速ストレート 外科用ストレート
タイプ 保存修復用 外科用 一般ストレート 外科用ストレート
ヘッド形状 アングルヘッド 外科用アングルヘッド ストレート形状 外科用ストレート形状
伝達方式 等速1:1 等速1:1 機種仕様による 機種仕様による
作動方式 連続回転 連続回転 連続回転 連続回転
対応器具 RA / CAバー 適合するRA外科用器具 HPシャンク器具 指定された外科用器具
注水方式 内部注水 外部注水 機種仕様による 機種仕様による
主な用途 う蝕除去・修復物の仕上げ 適応する外科切削・形態修正 義歯調整・研磨 適応する口腔外科処置
モーター適合性 適合するエアモーター 適合するエアモーター 適合するエアモーター 適合するエアモーター

実際の許容回転数、注水方式、使用可能なバーの寸法は、選択する機種の製品仕様に従って確認してください。

等速1:1低速コントラアングルハンドピース

Kaneiko 1:1低速コントラアングルハンドピース は、う蝕除去、保存修復処置、仕上げ、一般的なチェアサイド処置に適したモデルです。

1:1の等速伝達機構により、入力回転数を増減速せずにバーへ伝達します。適合するモーターおよび製品仕様に応じて、最大40,000 rpmまで使用できるモデルがあります。

アングルヘッドにより臼歯部などへのアクセスを確保しやすく、適合するRAラッチ式バーでう蝕除去、修復物の形態修正、仕上げを行います。

Model Cは光伝達機能を備え、Model C100はライト非対応仕様です。両モデルとも内部注水方式を採用し、軸径2.35 mmの適合するRAバーを使用します。

外科用等速1:1低速コントラアングルハンドピース

Kaneiko 1:1外科用低速コントラアングルハンドピース は、適応する口腔外科切削や形態修正などの処置を目的としています。

アングルヘッドにより口腔内の狭い外科処置部位へのアクセスをサポートします。等速1:1の伝達機構により、モーターの入力回転数をそのまま切削器具へ伝達します。

外部注水方式を採用し、承認された外科処置中に切削器具へ冷却水を供給します。

Model CXは光伝達機能を備え、Model CX100はライト非対応です。実際の処置に使用できる器具と注水条件を確認してください。

低速ストレートハンドピース

Kaneikoの低速ストレートハンドピースは、適合するHPシャンクの切削・仕上げ・研磨器具を使用するためのストレート形状のハンドピースです。

直線的な本体形状により、義歯の口腔外調整、技工関連作業、義歯床用レジンの削合や研磨などで実用的な操作性を提供します。

適切な器具と回転数で使用することにより、義歯の形態修正、補綴材料の平滑化、口腔外での仕上げ・研磨に対応します。

使用するHPバーの軸径、許容回転数、モーターとの接続規格を確認してください。ストレートハンドピースとRAラッチ式バーを使用するコントラアングルは、異なる器具保持方式です。

外科用低速ストレートハンドピース

Kaneikoの外科用低速ストレートハンドピースは、直線的な作業形状とモーター駆動による回転操作を必要とする、適応する口腔外科処置向けのモデルです。

指定された外科用器具を使用し、承認された外科切削や形態修正などの処置に対応します。

外科用途での使用には、器具の保持方式、許容回転数、注水方式、モーターとの適合性を確認する必要があります。

一般的なストレートハンドピースと外科用ストレートハンドピースは、必ずしも同じ用途で使用できません。製品ごとに指定された臨床用途と使用条件を確認してください。

臨床上の特長

低速での回転コントロール
保存修復物の仕上げや形態調整、適応する外科処置に必要な回転操作をサポートします。

異なる作業形状からの選択
コントラアングルとストレートの形状を、処置部位や作業内容に合わせて選択できます。

口腔内へのアクセス性
コントラアングルヘッドは、臼歯部や狭い処置部位へのアクセスをサポートします。

口腔外での操作性
ストレートハンドピースは、適合するHP器具を使用した義歯調整や研磨に適しています。

外科用モデルの選択肢
外科用コントラアングルおよび外科用ストレートモデルは、承認された処置に対応します。

器具に応じた適合性
各機種に適したRAバー、HP器具、外科用器具を選択できます。

購入前の確認事項

  • コントラアングルとストレートのどちらが必要かを確認
  • 保存修復、口腔外調整、外科処置の用途を確認
  • 歯科用エアモーターとの接続規格を確認
  • 許容入力回転数と出力回転数を確認
  • RAバー、HPバー、外科用器具の適合性を確認
  • 必要に応じて内部・外部注水方式を選択
  • ライト対応の必要性を確認
  • バーの軸径と保持機構を確認
  • 清掃・注油・滅菌方法を確認
  • 保守・交換部品の対応を確認

低速ハンドピースは回転数だけでなく、処置内容、使用器具、作業角度を考慮して選択してください。

用途別低速ハンドピースの選び方

う蝕除去・保存修復物の仕上げ
適合するRAバーを使用する等速1:1コントラアングルが適しています。

口腔内での外科的な切削・形態修正
アングルヘッドと外部注水が必要な場合は、適応する外科用1:1コントラアングルを選択します。

義歯調整
HPシャンクの切削器具や研削器具を使用する低速ストレートハンドピースを選択します。

義歯の仕上げ・研磨
口腔外での仕上げには、適合する研磨器具を装着できるストレートハンドピースが適しています。

適応する口腔外科処置
直線的な作業形状が必要な場合は、承認された器具と注水条件に対応する外科用ストレートハンドピースを選択します。

RAバーとHPバーの適合性

低速ハンドピースで使用するバーは、機種の保持方式、軸径、許容回転数によって異なります。

RA / CAラッチ式バー
等速1:1コントラアングルでは、軸径2.35 mmでラッチ保持用の溝を備えたRAバーを使用するモデルがあります。

HPストレート用バー
ストレートハンドピースでは、通常、RAタイプのラッチ溝を持たない軸径2.35 mmの適合するHP器具を使用します。

外科用器具
外科用モデルでは、保持方式と使用目的に適合する指定された外科用器具を使用してください。

RAバーとHPバーは軸径が同じ場合でも、保持構造が異なるため、無条件に共用できません。

詳しくは FG・RA・HPバーの適合性ガイド をご参照ください。

内部注水方式と外部注水方式

注水方式と冷却条件は、ハンドピースの構造や処置内容によって異なります。

内部注水方式
一部の等速1:1保存修復用コントラアングルでは、ハンドピース内部の注水経路から切削部位へ冷却水を供給します。

外部注水方式
外科用コントラアングルの一部では、外部注水パイプから処置部位へ冷却水を供給します。

ストレートハンドピース
必要な注水方式は、選択する機種、器具、口腔外作業か外科処置かによって異なります。

外科切削では、製品の使用条件に従った適切な注水と冷却を行ってください。

ライト対応モデルと非ライト対応モデル

Kaneikoの一部低速コントラアングルは、光伝達機能を備えています。口腔内処置時の視認性向上をサポートします。

光伝達機能を使用するには、対応するモーターおよび接続システムが必要です。ライト非対応モデルは、診療用照明で十分な視野が確保できる環境に適しています。

購入前に、選択した機種とモーターのライト対応仕様を確認してください。

歯科用エアモーターとの適合性

Kaneikoの低速コントラアングルおよびストレートハンドピースは、接続規格と使用条件に適合する歯科用エアモーターと組み合わせて使用します。

等速1:1コントラアングル
対応するエアモーターからの回転を等速で伝達し、保存修復処置や仕上げに使用します。

外科用等速1:1コントラアングル
適合するモーターと組み合わせ、承認された外科処置に必要な回転動力を得ます。

低速ストレートハンドピース
適合するエアモーターを使用し、義歯の形態修正、仕上げ、研磨などを行います。

外科用ストレートハンドピース
機種の許容回転数、注水条件、使用器具が適合するモーターと組み合わせ、承認された外科用途に使用します。

使用前には、接続規格、許容回転数、注水方式、器具の適合性を確認してください。機械的な接続だけでは、すべての外科処置に使用できるとは限りません。

メンテナンスと滅菌

適切なメンテナンスは、低速ハンドピースの円滑な回転、器具の保持性能、安定した作動に重要です。

使用後は切削・研磨器具を取り外し、外装、ヘッド部、必要に応じて注水経路を清掃・点検してください。

注油が必要な場合は、製品に指定された注油口と潤滑剤を使用し、メーカーが定める頻度と手順で注油してください。

異音、振動、過熱、回転不良が見られる場合は、清掃、注油、点検、修理の必要性を確認してください。

滅菌は、各製品に指定された温度、滅菌サイクル、乾燥条件に従って実施してください。

詳しくは Kaneiko歯科用ハンドピースのメンテナンスガイド をご参照ください。

臨床現場での選択ポイント

低速ハンドピースの選択では、最高回転数よりも、使用する器具の形状と処置部位を優先して検討することが重要です。

等速1:1コントラアングルは、口腔内でのう蝕除去や修復物の仕上げに適しています。 一方、ストレートハンドピースは、適合するHP器具による義歯調整や口腔外仕上げに適しています。

外科用モデルは、一般診療用と異なる適応や注水条件を持つ場合があります。承認された用途を確認し、適切な器具を使用してください。

バーの適合性、モーターとの接続、冷却、日常メンテナンスは、安定した臨床性能を維持するために欠かせません。

Kaneiko低速歯科用ハンドピースのメリット

  • 保存修復や仕上げに適した低速回転
  • コントラアングルとストレートから選択可能
  • 適合するRAバーによるう蝕除去に対応
  • コンポジットレジンの形態修正・仕上げに対応
  • HP器具を使用した義歯調整に対応
  • 口腔外での仕上げ・研磨に対応
  • 外科用コントラアングルとストレートモデルを用意
  • 機種に応じた注水方式を選択可能
  • 一部モデルに光伝達機能を用意
  • 適合する歯科用エアモーターとの接続に対応

よくあるご質問(FAQ)

1. 低速歯科用ハンドピースとは何ですか?
モーター駆動による回転を利用し、う蝕除去、修復物の仕上げ、研磨、適応する外科処置などに使用する歯科用器具です。

2. コントラアングルとストレートハンドピースの違いは何ですか?
コントラアングルは角度付きヘッドを備え、口腔内へのアクセスに適しています。ストレートは直線的な形状で、義歯の口腔外調整や適応する外科処置などに使用します。

3. 等速1:1コントラアングルは何に使用しますか?
う蝕除去、コンポジットレジンの仕上げ、修復物辺縁部の調整などに使用します。

4. 等速1:1コントラアングルにはどのバーを使用しますか?
適合する軸径2.35 mmのRAラッチ式バーを使用するモデルがあります。

5. 低速ストレートハンドピースは何に使用しますか?
義歯調整、口腔外での仕上げ・研磨、適合する技工関連作業などに使用します。

6. ストレートハンドピースにはどの器具が適合しますか?
通常、機種仕様に適合するHPシャンクのバーや研磨器具を使用します。

7. 低速ハンドピースは支台歯形成にも使用できますか?
適応する仕上げ処置に使用できる場合がありますが、広範囲の支台歯形成には一般的に適切な高速切削システムが使用されます。

8. 外科用低速ハンドピースは一般診療用と異なりますか?
はい。外科用モデルではヘッド形状、注水方式、対応器具、承認された用途が異なる場合があります。

9. Kaneikoの低速ハンドピースは歯科用エアモーターに対応していますか?
本シリーズには、適合する歯科用エアモーターとの接続を想定したモデルがあります。接続規格と使用条件を機種ごとに確認してください。

10. RAバーをストレートハンドピースに使用できますか?
メーカーが明確に指定していない限り使用しないでください。ストレートでは通常、RAラッチ式バーとは異なるHPシャンク器具を使用します。

11. 低速ハンドピースには注水が必要ですか?
必要な冷却条件は処置と機種によって異なります。外科切削などでは適切な注水が必要となる場合があります。

12. 低速ハンドピースのメンテナンス方法は?
製品の取扱説明書に従い、使用後の清掃、必要な注油、点検、滅菌を実施してください。