Electric Contra Angle Handpiece

Explore the KANEIKO Electric Handpiece collection. This page features electric dental handpieces designed for stable torque, precise cutting, and smooth clinical performance. Suitable for procedures such as crown preparation, cavity preparation, and restorative treatments, these handpieces provide consistent power and reliable operation for daily clinical use.

Skip to results list
2 items
Column grid
Column grid

Filter

Electric Contra-Angle Handpiece Series

More About Electric Contra-Angle Handpieces

Kaneiko electric contra-angle dental handpieces feature speed-increasing transmissions designed for efficient cutting, precise handling and controlled performance during restorative and oral surgical procedures.

This collection includes 1:5 speed-increasing electric contra-angle handpieces for high-speed restorative preparation and 1:4.2 surgical speed-increasing contra-angle handpieces specifically for oral surgical cutting. Both configurations increase the rotational speed supplied by a compatible dental motor, but their clinical applications and head designs differ.

The 1:5 configuration supports crown preparation, cavity preparation, veneer preparation and restoration removal using compatible FG burs. The 1:4.2 configuration features a 45-degree surgical head for approved oral surgical procedures, including tooth sectioning.

Both models require a compatible motor connection, appropriate operating speed, secure bur retention and suitable irrigation. Their different clinical indications should be considered when selecting a handpiece.

Introducing Electric Speed-Increasing Handpieces in Clinical Dentistry

A speed-increasing contra-angle handpiece uses internal gearing to multiply the rotational speed supplied by a dental motor. Unlike a 1:1 direct-drive contra-angle, which maintains motor speed, a speed-increasing handpiece allows a suitable motor to drive its cutting instrument at a higher rotational speed.

A 1:5 transmission increases input rotation fivefold. For example, a compatible motor operating at 40,000 rpm produces a theoretical output of 200,000 rpm, provided the handpiece is approved for that operating speed.

A 1:4.2 transmission multiplies input rotation by 4.2 times. The Kaneiko 1:4.2 model is a dedicated surgical handpiece with a 45-degree head designed for compatible oral surgical cutting procedures.

Speed-increasing technology should not be evaluated by maximum rpm alone. Motor performance, cutting-instrument condition, bearing stability, head design, irrigation and applied cutting pressure all influence clinical operation.

What Are Electric Contra-Angle Handpieces Used For?

Crown and Bridge Preparation
The 1:5 speed-increasing handpiece supports tooth reduction, axial preparation, occlusal clearance and finishing of crown and bridge preparations using suitable FG burs.

Cavity Preparation
The 1:5 configuration provides high-speed cutting for enamel and dentine preparation during restorative treatment.

Veneer Preparation
Compatible FG diamond burs allow controlled enamel reduction and preparation of surfaces for indirect veneer restorations.

Removal of Existing Restorations
The 1:5 handpiece can be used with suitable FG burs for cutting and removing composite and selected existing restorative materials.

Inlay and Onlay Preparation
The 1:5 handpiece supports preparation of internal walls, occlusal surfaces and restoration margins using compatible instruments.

Oral Surgical Cutting
The 1:4.2 surgical speed-increasing handpiece is specifically intended for approved oral surgical cutting procedures using compatible surgical burs.

Tooth Sectioning
The 45-degree head of the 1:4.2 surgical model provides an angled working position for compatible tooth sectioning and selected posterior surgical procedures.

Kaneiko Electric Handpieces: Designed for Speed, Cooling and Control

Kaneiko electric speed-increasing handpieces provide two distinct configurations to meet the different cutting requirements of restorative dentistry and oral surgery.

Key design considerations across the collection include:

  • 1:5 speed-increasing transmission for restorative cutting
  • 1:4.2 speed-increasing transmission for surgical cutting only
  • High-speed output from compatible motor input
  • FG bur compatibility for the 1:5 restorative model
  • Approved surgical bur compatibility for the 1:4.2 model
  • 45-degree surgical head for compatible oral surgical access
  • Model-specific water cooling and irrigation arrangements
  • Secure cutting-instrument retention
  • Compatibility with suitable dental air motors under approved operating conditions

The appropriate configuration depends on whether the clinical procedure requires routine high-speed restorative preparation or dedicated surgical cutting.

Electric Contra-Angle Handpiece Model Comparison

Feature 1:5 Speed-Increasing 1:4.2 Surgical Speed-Increasing
Handpiece Type Restorative Speed-Increasing Surgical Speed-Increasing
Transmission Ratio 1:5 1:4.2
Speed Transmission 5× Input Speed 4.2× Input Speed
Operating Movement Continuous Rotation Continuous Rotation
Head Design Restorative Contra-Angle Head 45° Surgical Head
Instrument Compatibility Compatible FG Burs Approved Surgical Burs
Main Application Crown, Cavity and Veneer Preparation Oral Surgical Cutting and Tooth Sectioning
Motor Compatibility Compatible Dental Air Motors Compatible Dental Air Motors
Clinical Category Restorative Dentistry Oral Surgery Only

Actual rotational speed, permissible instrument types and irrigation requirements depend on the selected handpiece and connected motor. Follow the rated operating specifications for each model.

1:5 Speed-Increasing Electric Contra-Angle Handpiece

The Kaneiko 1:5 speed-increasing contra-angle handpiece is designed for restorative and prosthodontic procedures requiring efficient high-speed tooth preparation.

Its internal gearing multiplies motor input speed by five times. A compatible 40,000 rpm motor can theoretically produce up to 200,000 rpm at the bur, subject to the handpiece's rated maximum speed.

The handpiece accepts suitable FG friction-grip burs for crown preparation, cavity preparation, veneer preparation, enamel reduction and removal of selected restorative materials.

Stable motor performance, secure bur retention and effective water cooling are important for maintaining precise cutting and controlling heat during treatment.

This model is intended for high-speed restorative preparation rather than replacing a dedicated surgical contra-angle or implant reduction handpiece.

1:4.2 Surgical Speed-Increasing Contra-Angle Handpiece

The Kaneiko 1:4.2 surgical speed-increasing contra-angle handpiece is specifically designed for oral surgical cutting procedures requiring a high-speed surgical instrument.

Its 1:4.2 transmission multiplies compatible motor input speed by 4.2 times. The 45-degree surgical head provides an angled approach to selected posterior and oral surgical working areas.

The handpiece supports approved surgical cutting and tooth sectioning procedures using compatible surgical burs and the appropriate irrigation system.

The surgical head design should be used according to the model's approved operating conditions, including permitted bur type, input speed and cooling requirements.

The 1:4.2 model is intended exclusively for surgical applications. It is not designed for routine crown preparation, cavity preparation, veneer preparation or composite finishing.

Clinical Benefits

Speed-Increasing Transmission
Both models multiply motor input speed to provide higher rotational output for their approved cutting applications.

Efficient Restorative Cutting
The 1:5 model supports crown, cavity and veneer preparation using compatible FG burs.

Dedicated Surgical Configuration
The 1:4.2 model provides a 45-degree surgical head for approved oral surgical cutting procedures.

Improved Access
Angled head configurations help clinicians position cutting instruments in posterior and confined treatment areas.

Instrument-Specific Performance
Each model is designed for suitable cutting instruments and its intended clinical applications.

Cooling Support
Appropriate water irrigation helps manage frictional heat during high-speed cutting.

Buying Considerations

  • Confirm whether the procedure is restorative or surgical
  • Choose 1:5 for high-speed restorative preparation
  • Choose 1:4.2 for approved oral surgical cutting only
  • Check motor connection and maximum permitted input speed
  • Confirm FG or surgical bur compatibility
  • Verify the approved bur dimensions and retention system
  • Check the irrigation configuration and cooling requirements
  • Consider head angle and access to the treatment area
  • Confirm cleaning, lubrication and sterilisation requirements
  • Check availability of maintenance and replacement support

The higher transmission ratio is not automatically the better option. Handpiece selection should begin with the intended clinical procedure and approved instrument system.

How to Choose the Right Electric Contra-Angle Handpiece

For Crown and Bridge Preparation
Choose the 1:5 speed-increasing model for high-speed tooth reduction using suitable FG burs.

For Cavity Preparation
The 1:5 model supports high-speed enamel and dentine preparation during restorative procedures.

For Veneer Preparation
Choose the 1:5 configuration with suitable FG diamond burs for planned enamel reduction.

For Oral Surgical Cutting
Choose the 1:4.2 surgical model with its 45-degree head and approved surgical burs.

For Tooth Sectioning
Use the 1:4.2 surgical configuration only when the procedure, bur and irrigation system are approved for that model.

For Dental Air Motor Compatibility
Confirm the handpiece connection, motor output, maximum input speed and cooling requirements before purchasing.

FG and Surgical Bur Compatibility

Bur compatibility differs between the restorative and surgical electric handpieces. The correct instrument must match the handpiece's retention system, approved speed and clinical application.

1:5 Restorative Contra-Angle
Uses compatible FG friction-grip burs for high-speed restorative cutting. Standard FG burs typically have a 1.6 mm shank, but permissible bur length and dimensions must follow the selected model's instructions.

1:4.2 Surgical Contra-Angle
Requires approved surgical burs suitable for the 45-degree head, instrument retention system and permitted operating speed.

A surgical cutting bur should not be assumed compatible with the restorative handpiece, or vice versa, without confirming the manufacturer's specifications.

For more information about different dental bur systems, read the FG, RA and HP Bur Compatibility Guide for Dental Handpieces .

Water Cooling and Irrigation

High-speed cutting generates frictional heat, making effective cooling important during restorative preparation and approved surgical cutting.

Restorative Water Cooling
The 1:5 handpiece requires suitable water cooling during crown preparation, cavity preparation and other cutting procedures.

Surgical Irrigation
The 1:4.2 surgical handpiece requires an appropriate irrigation arrangement for its approved surgical applications.

Before treatment, inspect the irrigation pathway and confirm that cooling reaches the working end of the cutting instrument.

Blocked water outlets or inadequate cooling may increase the risk of excessive heat during cutting.

Dental Air Motor Compatibility

Kaneiko 1:5 and 1:4.2 speed-increasing contra-angle handpieces are designed for connection to compatible dental air motors, subject to their model-specific connection, input speed and operating requirements.

1:5 Restorative Model
A suitable dental air motor can supply the rotational input for speed-increasing restorative cutting when its output and cooling configuration meet the handpiece specifications.

1:4.2 Surgical Model
A compatible dental air motor may drive the surgical speed-increasing transmission when the required operating limits, irrigation and surgical conditions are satisfied.

Mechanical connection compatibility alone does not confirm appropriate cutting performance. Verify the motor's speed, output characteristics, connection and irrigation support before clinical use.

Maintenance and Sterilisation

Proper maintenance supports smooth rotation, secure bur retention and reliable performance of speed-increasing contra-angle handpieces.

After treatment, remove the cutting instrument, clean the handpiece exterior and inspect the head and irrigation pathway according to the manufacturer's instructions.

Lubricate through the designated port when required, using the recommended lubricant and application method.

Unusual noise, vibration, overheating or reduced rotational performance may indicate that inspection or servicing is needed.

Sterilise each model using its approved sterilisation cycle and drying requirements.

Read the Kaneiko Dental Handpiece Maintenance Guide for additional care and maintenance guidance.

Professional Insight

Although 1:5 and 1:4.2 handpieces both use speed-increasing transmissions, their applications are different.

The 1:5 model is intended for restorative preparation where suitable FG burs are used for efficient enamel and dentine cutting.

The 1:4.2 model is a dedicated surgical configuration. Its 45-degree head provides an approach suited to selected surgical cutting and tooth sectioning procedures.

These models should not be selected solely by comparing their transmission ratios. The operating head, approved burs, irrigation arrangement and clinical indication are equally important.

Benefits of Using Kaneiko Electric Contra-Angle Handpieces

  • Provide speed-increasing transmission for approved cutting procedures
  • Support crown and cavity preparation using the 1:5 configuration
  • Support veneer preparation with compatible FG diamond burs
  • Offer a dedicated 1:4.2 surgical cutting configuration
  • Provide a 45-degree surgical head for selected oral surgical access
  • Support precise instrument positioning during clinical procedures
  • Allow model-specific bur compatibility
  • Support suitable cooling during high-speed cutting
  • Connect to compatible dental air motors
  • Provide distinct restorative and surgical product options

Frequently Asked Questions

1. What is an electric speed-increasing contra-angle handpiece?
It is a dental contra-angle handpiece that uses internal gearing to increase the rotational speed supplied by a compatible dental motor.

2. What is a 1:5 speed-increasing handpiece used for?
It is used for high-speed restorative procedures such as crown preparation, cavity preparation, veneer preparation and restoration removal.

3. What does a 1:5 gear ratio mean?
A 1:5 transmission multiplies the connected motor's rotational speed by five times, subject to the handpiece's rated operating limits.

4. What is the maximum rotational speed of a 1:5 handpiece?
With a compatible 40,000 rpm motor, the theoretical output is 200,000 rpm. Actual permissible speed depends on the model specifications.

5. What is a 1:4.2 surgical contra-angle used for?
It is designed specifically for approved oral surgical cutting and tooth sectioning using compatible surgical burs.

6. Can the Kaneiko 1:4.2 handpiece be used for crown preparation?
No. This model is intended for oral surgical applications only, not routine restorative crown or cavity preparation.

7. What is the difference between 1:5 and 1:4.2 handpieces?
The 1:5 is intended for high-speed restorative preparation, while the 1:4.2 is a dedicated 45-degree surgical cutting handpiece.

8. What dental burs are compatible?
The 1:5 model uses compatible FG burs. The 1:4.2 surgical model requires approved surgical burs according to its retention and operating specifications.

9. Can these handpieces connect to dental air motors?
Both are designed for compatible dental air motor connections, subject to the selected model's input speed and operating requirements.

10. Is water cooling required?
Appropriate cooling is important for high-speed restorative and surgical cutting. Follow the irrigation instructions for each model.

11. Can a speed-increasing handpiece replace an implant handpiece?
No. Implant drilling and placement require an appropriate reduction handpiece and surgical motor system with suitable torque control.

12. How should electric contra-angle handpieces be maintained?
Remove the bur, clean the handpiece, lubricate as instructed, inspect for abnormal operation and sterilise according to the product manual.

増速コントラアングルハンドピースシリーズ

増速コントラアングルハンドピースについて

Kaneikoの 増速コントラアングルハンドピース は、モーターの回転数を増速し、精密な切削操作と安定した臨床性能を実現することを目的とした歯科用ハンドピースです。 保存修復・補綴処置および口腔外科処置に対応する専用モデルをラインアップしています。

本シリーズには、 増速1:5コントラアングルハンドピース と 外科用増速1:4.2コントラアングルハンドピース の2種類があります。 どちらも適合する歯科用モーターの回転数を増速する機構を備えていますが、ヘッド形状と臨床用途が異なります。

増速1:5タイプは、支台歯形成、窩洞形成、ラミネートベニア形成、既存修復物の除去などに使用します。 一方、外科用増速1:4.2タイプは、45度ヘッドを採用した口腔外科処置専用モデルであり、適合する外科用バーを用いた切削や歯牙分割に対応します。

どちらの機種も、適合するモーター、許容入力回転数、バーの保持方式、注水条件を確認したうえで使用する必要があります。

歯科診療における増速コントラアングルの役割

増速コントラアングルハンドピースは、内部ギアによってモーターの入力回転数を増速し、高速切削を可能にする歯科用ハンドピースです。

モーターの回転数をそのまま伝達する等速1:1タイプとは異なり、増速タイプでは入力回転数より高い出力回転数を得られます。

増速1:5タイプ は入力回転数を5倍に増速します。 例えば、40,000 rpmの適合モーターを使用した場合、理論上の出力回転数は200,000 rpmとなります。ただし、製品に定められた最高許容回転数を超えないことが前提です。

外科用増速1:4.2タイプ は入力回転数を4.2倍に増速するモデルです。45度の外科用ヘッドを備え、適合する口腔外科領域の切削処置を目的としています。

臨床性能は最高回転数だけで決まるものではありません。 モーターの出力特性、バーの状態、ヘッド形状、回転の安定性、注水による冷却、切削時の加圧なども重要です。

増速コントラアングルハンドピースの主な用途

クラウン・ブリッジの支台歯形成
増速1:5タイプと適切なFGバーを組み合わせ、軸面形成、咬合面の削除、支台歯形成の仕上げなどに使用します。

窩洞形成
増速1:5タイプは、保存修復処置におけるエナメル質や象牙質の切削、窩洞形成に対応します。

ラミネートベニア形成
適合するFGダイヤモンドバーを使用し、エナメル質の削合やベニア形成に対応します。

既存修復物の除去
増速1:5タイプは、適切なFGバーによるコンポジットレジンや一部修復材料の切削・除去に使用できます。

インレー・アンレー窩洞形成
増速1:5タイプは、修復物の設計に応じた窩洞内面、咬合面、形成辺縁の調整に対応します。

口腔外科領域の切削
外科用増速1:4.2タイプは、適合する外科用バーを使用した承認範囲内の口腔外科切削処置専用です。

歯牙分割
外科用増速1:4.2タイプの45度ヘッドは、適応する歯牙分割や臼歯部の外科処置における器具のアクセスを考慮した設計です。

Kaneiko増速コントラアングルの設計上の特長

Kaneikoの 増速コントラアングルハンドピース は、保存修復・補綴処置向けの1:5タイプと、口腔外科処置専用の1:4.2タイプを用意しています。

主な設計上の特徴は以下のとおりです。

  • 増速1:5:保存修復・補綴処置向けの高速切削
  • 外科用増速1:4.2:口腔外科処置専用の増速機構
  • 適合するモーターからの入力回転数を増速
  • 1:5モデルは適合するFGバーを使用
  • 1:4.2モデルは指定された外科用バーを使用
  • 45度外科用ヘッドによる処置部位へのアクセス
  • 機種ごとの注水・冷却条件
  • 確実なバー保持と適切な回転操作
  • 使用条件を満たす歯科用エアモーターに対応

処置内容に応じて適切な機種を選択し、器具の保持方式や使用条件を確認することが重要です。

増速コントラアングルハンドピースの比較

比較項目 増速1:5 外科用増速1:4.2
タイプ 保存修復用増速タイプ 外科用増速タイプ
ギア比 1:5 1:4.2
回転伝達 入力回転数の5倍 入力回転数の4.2倍
作動方式 連続回転 連続回転
ヘッド形状 保存修復用コントラアングルヘッド 45度外科用ヘッド
対応器具 適合するFGバー 指定された外科用バー
主な用途 支台歯形成・窩洞形成・ベニア形成 口腔外科切削・歯牙分割
モーター適合性 適合する歯科用エアモーター 適合する歯科用エアモーター
臨床分野 保存修復・補綴 口腔外科専用

実際の出力回転数、使用できるバーの種類、注水条件は各機種および接続モーターの仕様によって異なります。

増速1:5コントラアングルハンドピース

Kaneikoの増速1:5コントラアングルハンドピースは、支台歯形成や窩洞形成など、高速切削を必要とする保存修復・補綴処置向けのモデルです。

内部ギアによってモーターの入力回転数を5倍に増速します。 40,000 rpmの適合モーターを使用した場合、理論上200,000 rpmの出力回転数が得られます。ただし、製品の許容最高回転数の範囲内で使用してください。

適合するFGバーを使用し、支台歯形成、窩洞形成、ラミネートベニア形成、歯質削除、既存修復物の除去などに対応します。

安定したモーター出力、確実なバー保持、適切な注水による冷却は、切削精度と安全性を確保するうえで重要です。

このモデルは高速での保存修復処置向けであり、外科専用ハンドピースやインプラント用減速ハンドピースの代替として使用するものではありません。

外科用増速1:4.2コントラアングルハンドピース

Kaneikoの外科用増速1:4.2コントラアングルハンドピースは、口腔外科領域における高速切削を目的とした専用モデルです。

1:4.2の増速機構により、適合するモーターの入力回転数を4.2倍に増速します。 45度の外科用ヘッドは、臼歯部などの外科処置における切削器具のアクセス性を考慮した設計です。

適合する外科用バーと適切な注水システムを使用し、承認された外科切削や歯牙分割に対応します。

使用するバーの種類、許容入力回転数、冷却条件は製品の仕様に従って確認してください。

本モデルは口腔外科処置専用です。 一般的な支台歯形成、窩洞形成、ラミネートベニア形成、コンポジットレジンの仕上げには使用しません。

臨床上の特長

増速機構による高速切削
どちらのモデルも入力回転数を増速し、それぞれの用途に適した高速回転を提供します。

保存修復処置での切削効率
増速1:5タイプは、FGバーを使用した支台歯形成や窩洞形成に対応します。

外科処置専用設計
外科用増速1:4.2タイプは、45度ヘッドを備えた口腔外科処置専用モデルです。

処置部位へのアクセス性
コントラアングル形状により、臼歯部や狭い処置部位での器具の位置付けをサポートします。

用途別の器具適合性
それぞれのモデルに指定された切削器具を使用します。

適切な冷却への対応
処置内容に応じた注水は、高速切削時の摩擦熱の管理に役立ちます。

購入前の確認事項

  • 保存修復処置か口腔外科処置かを確認する
  • 支台歯形成・窩洞形成には増速1:5タイプを選択する
  • 外科切削には外科用増速1:4.2タイプを選択する
  • モーターとの接続規格を確認する
  • 許容入力回転数を確認する
  • FGバーまたは外科用バーの適合性を確認する
  • バーの寸法と保持方式を確認する
  • 注水方式と必要な冷却条件を確認する
  • ヘッド形状と処置部位へのアクセス性を検討する
  • 清掃・注油・滅菌方法を確認する

ギア比の数値だけで選ぶのではなく、処置目的と使用器具の適合性を優先して選択してください。

用途別の選び方

クラウン・ブリッジの支台歯形成
適切なFGバーを用いた歯質削除には、増速1:5タイプを選択します。

窩洞形成
保存修復処置における高速切削には、増速1:5タイプが対応します。

ラミネートベニア形成
適合するFGダイヤモンドバーと組み合わせ、増速1:5タイプを使用します。

口腔外科切削
適合する外科用バーを使用する処置には、45度ヘッドを備えた増速1:4.2タイプを選択します。

歯牙分割
適応する歯牙分割では、製品の使用条件に従い、外科用増速1:4.2タイプを使用します。

モーターとの適合性
購入前に接続規格、許容入力回転数、モーター性能、注水条件を確認してください。

FGバーと外科用バーの適合性

増速1:5モデルと外科用増速1:4.2モデルでは、使用するバーや臨床用途が異なります。 各ハンドピースの保持方式、許容回転数、製品仕様に適合する切削器具を使用してください。

増速1:5モデル
高速での保存修復処置に適したFGバーを使用します。一般的なFGバーの軸径は1.6 mmですが、使用可能なバーの長さや寸法は機種の仕様に従ってください。

外科用増速1:4.2モデル
45度外科用ヘッドの保持機構と許容回転数に適合する、指定された外科用バーを使用します。

保持方式や使用条件を確認せず、異なる機種間でバーを共用しないでください。

バーの規格については、 FG・RA・HPバーの適合性ガイド もご参照ください。

注水と冷却について

高速切削では摩擦熱が発生するため、保存修復処置や外科切削において適切な冷却が重要です。

保存修復処置時の注水
増速1:5タイプで支台歯形成や窩洞形成を行う際は、製品仕様に適した注水・冷却を行ってください。

外科処置時の注水
外科用増速1:4.2タイプでは、承認された外科処置に適した注水方式を使用します。

処置前には注水経路を点検し、切削器具の先端付近に冷却水が十分に届くことを確認してください。

注水口の詰まりや冷却不足は、切削時の過度な発熱につながるおそれがあります。

歯科用エアモーターとの適合性

Kaneikoの増速1:5および外科用増速1:4.2コントラアングルハンドピースは、接続規格や許容入力回転数などの条件に適合する歯科用エアモーターとの組み合わせを想定しています。

増速1:5モデル
モーターの出力特性、接続規格、注水条件が適合する場合、歯科用エアモーターからの回転を増速して保存修復処置に使用できます。

外科用増速1:4.2モデル
許容入力回転数、注水方式、外科処置に必要な条件を満たすエアモーターと組み合わせて使用します。

機械的に接続できるだけでは、十分な切削性能や臨床上の適合性が確認されたことにはなりません。 使用前にモーター性能、接続規格、注水条件を確認してください。

メンテナンスと滅菌

適切なメンテナンスは、増速コントラアングルハンドピースの円滑な回転、確実なバー保持、性能維持に重要です。

使用後はバーを取り外し、製品の取扱説明書に従って外装、ヘッド部、注水経路を清掃・点検してください。

注油が必要な機種では、指定された注油口と潤滑剤を使用し、定められた方法で注油してください。

異音、振動、過熱、回転性能の低下が発生した場合は、点検や修理が必要な可能性があります。

滅菌は各製品に指定された滅菌サイクルおよび乾燥条件に従って実施してください。

詳しくは Kaneiko歯科用ハンドピースのメンテナンスガイド をご参照ください。

臨床現場での選択ポイント

増速1:5タイプと外科用増速1:4.2タイプは、どちらも増速機構を備えていますが、使用目的は異なります。

増速1:5タイプは、適合するFGバーを用いた支台歯形成や窩洞形成などの保存修復処置向けです。

一方、外科用増速1:4.2タイプは45度の外科用ヘッドを備え、適応する口腔外科切削や歯牙分割を目的としています。

両モデルはギア比だけで比較せず、ヘッド形状、使用可能なバー、注水方式、臨床上の適応を基準に選択することが重要です。

Kaneiko増速コントラアングルハンドピースのメリット

  • 用途に応じた増速機構を採用
  • 増速1:5タイプによる支台歯形成・窩洞形成
  • FGダイヤモンドバーを用いたラミネートベニア形成
  • 外科用増速1:4.2タイプによる専用切削処置
  • 45度外科用ヘッドによる処置部位へのアクセス
  • 口腔内での器具の位置付けをサポート
  • 各機種に適したバーの保持方式
  • 適切な注水による切削時の冷却
  • 適合する歯科用エアモーターに対応
  • 保存修復用と外科用から選択可能

よくあるご質問(FAQ)

1. 増速コントラアングルハンドピースとは何ですか?
内部ギアによって、接続モーターの入力回転数を増速する歯科用ハンドピースです。

2. 増速1:5ハンドピースは何に使用しますか?
支台歯形成、窩洞形成、ラミネートベニア形成、既存修復物の除去など、高速切削を必要とする保存修復・補綴処置に使用します。

3. 1:5というギア比は何を意味しますか?
接続モーターの入力回転数を5倍に増速することを意味します。ただし、製品の許容回転数内で使用する必要があります。

4. 増速1:5の最高回転数は何rpmですか?
適合する40,000 rpmのモーターでは理論上200,000 rpmとなります。実際の許容最高回転数は製品仕様をご確認ください。

5. 外科用増速1:4.2はどのような用途に使用しますか?
適合する外科用バーを使用した口腔外科切削や歯牙分割など、承認された外科処置に使用します。

6. 外科用増速1:4.2は支台歯形成にも使用できますか?
いいえ。Kaneikoの1:4.2モデルは口腔外科処置専用であり、一般的な支台歯形成や窩洞形成には使用しません。

7. 増速1:5と外科用増速1:4.2の違いは何ですか?
増速1:5は保存修復・補綴処置向け、外科用増速1:4.2は45度ヘッドを備えた口腔外科切削専用モデルです。

8. 対応する歯科用バーは何ですか?
増速1:5は適合するFGバーを使用します。外科用増速1:4.2は、保持機構と使用条件に適合する指定された外科用バーを使用します。

9. 歯科用エアモーターに接続できますか?
両モデルとも、接続規格、許容入力回転数、その他の使用条件を満たす歯科用エアモーターとの組み合わせを想定しています。

10. 切削時には注水が必要ですか?
高速での歯質切削や外科切削には、処置内容と製品仕様に適した冷却が重要です。

11. 増速コントラアングルはインプラント用としても使用できますか?
いいえ。インプラント窩形成や埋入には、適切なトルク制御が可能なシステムと対応する減速ハンドピースを使用する必要があります。

12. 増速コントラアングルのメンテナンス方法は?
使用後はバーを取り外し、製品の指示に従って清掃、必要な注油、点検、滅菌を実施してください。