Contra Angle Handpiece Series

Explore Kaneiko 1:1 low-speed contra-angle handpieces designed for use with compatible electric micromotors and dental air motors. Featuring direct-drive 1:1 transmission, stable torque and controlled low-speed performance, this collection supports caries removal, composite finishing, margin refinement, endodontic access preparation and selected oral surgical procedures. Available restorative and surgical configurations provide reliable performance, precise handling and efficient daily clinical use.

Skip to results list
6 items
Column grid
Column grid

Filter

Contra-Angle Handpiece Series

More About Contra-Angle Handpieces

Kaneiko contra-angle dental handpieces are designed for controlled cutting, precise instrument movement and efficient clinical performance. Their angled head configuration improves intraoral access during restorative, orthodontic and surgical procedures.

The collection includes 1:1 direct-drive, 1:5 speed-increasing, 1:4.2 surgical speed-increasing, 20:1 implant reduction and 4:1 reciprocating contra-angle handpieces. Each transmission ratio supports a specific clinical application, from low-speed caries removal and high-speed crown preparation to oral surgery, implant placement and orthodontic interproximal reduction (IPR).

These handpieces are designed for connection to compatible dental air motors, subject to the individual model's operating specifications. Motor performance, bur compatibility, irrigation requirements and intended clinical use should be considered when selecting the appropriate configuration.

Introducing Contra-Angle Handpieces in Clinical Dentistry

A contra-angle handpiece is a dental instrument with an angled head designed to improve accessibility to posterior teeth and confined intraoral areas. Its configuration allows dentists to approach working surfaces at practical angles during different dental procedures.

The transmission ratio determines how rotational movement is transferred from the connected motor. A 1:1 direct-drive contra-angle maintains the input speed, while a 1:5 speed-increasing contra-angle multiplies motor speed by five times for high-speed restorative cutting.

A 1:4.2 surgical speed-increasing contra-angle multiplies input speed by 4.2 times and is dedicated to approved oral surgical cutting procedures. Its 45-degree surgical head is designed to facilitate access during selected surgical applications.

A 20:1 implant reduction contra-angle reduces input rotation while increasing available output torque for implant procedures. Meanwhile, a 4:1 reciprocating contra-angle converts motor rotation into back-and-forth movement for compatible orthodontic IPR strips.

These different operating mechanisms are not interchangeable. Clinicians should select the appropriate handpiece according to procedural requirements, motor capabilities and approved instrument compatibility.

What Are Contra-Angle Handpieces Used For?

Controlled Caries Removal
A 1:1 direct-drive contra-angle supports low-speed removal of affected dentine using compatible RA latch-type burs.

Crown and Bridge Preparation
A 1:5 speed-increasing contra-angle supports crown preparation, tooth reduction and bridge abutment preparation using suitable FG burs.

Cavity Preparation
A 1:5 handpiece provides high-speed cutting for enamel and dentine preparation during restorative treatment.

Composite Finishing and Adjustment
A compatible 1:1 low-speed contra-angle supports composite contouring, restorative finishing and occlusal adjustment.

Veneer Preparation
A 1:5 speed-increasing handpiece supports controlled enamel reduction and veneer preparation using compatible FG diamond burs.

Oral Surgical Cutting and Tooth Sectioning
The 1:4.2 surgical contra-angle is intended exclusively for approved surgical cutting and tooth sectioning using compatible surgical burs.

Dental Implant Surgery
A 20:1 implant reduction contra-angle supports controlled implant drilling and placement when connected to an appropriate surgical motor system.

Orthodontic Interproximal Reduction (IPR)
A 4:1 reciprocating contra-angle is designed exclusively for compatible IPR strips, producing controlled back-and-forth movement during planned interproximal enamel reduction.

Restoration Margin Refinement
A 1:1 direct-drive contra-angle supports controlled smoothing and finishing of restorative margins using suitable RA instruments.

Kaneiko Contra-Angle Handpieces: Designed for Precision and Clinical Control

Kaneiko contra-angle handpieces offer transmission configurations designed for specific restorative, orthodontic and surgical workflows.

Key design considerations include:

  • 1:1 direct-drive transmission for controlled low-speed procedures
  • 1:5 speed-increasing transmission for high-speed restorative preparation
  • 1:4.2 speed-increasing transmission for oral surgical cutting only
  • 45-degree surgical head for compatible surgical procedures
  • 20:1 reduction for implant drilling and placement
  • 4:1 reciprocating mechanism for compatible IPR strips only
  • Model-specific FG, RA, surgical bur and implant instrument compatibility
  • Internal or external irrigation configurations according to model
  • Fibre-optic and non-optic options on selected models
  • Compatibility with suitable dental air motors

Understanding these differences helps dentists choose appropriate rotational performance, instrument retention and working-head configurations for each clinical application.

Contra-Angle Handpiece Transmission Ratio Comparison

Feature 1:1 1:5 1:4.2 20:1 4:1
Handpiece Type Direct Drive Speed-Increasing Surgical Speed-Increasing Implant Reduction IPR Reciprocating
Transmission Ratio 1:1 1:5 1:4.2 20:1 4:1
Speed Transmission Input Speed Unchanged 5× Input Speed 4.2× Input Speed Input Speed ÷ 20 4:1 Reduction with Reciprocating Output
Operating Movement Continuous Rotation Continuous Rotation Continuous Rotation Continuous Rotation Reciprocating Motion
Instrument Compatibility RA / CA Burs FG Burs Compatible Surgical Burs Implant Drills and Drivers IPR Strips Only
Main Application Caries Removal and Finishing Crown and Cavity Preparation Oral Surgery Only Implant Surgery Orthodontic IPR Only
Motor Compatibility Compatible Dental Air Motor Compatible Dental Air Motor Compatible Dental Air Motor Compatible Dental Air Motor* Compatible Dental Air Motor

*Implant procedures require appropriate surgical speed, torque and irrigation control. A compatible motor connection alone does not establish suitability for implant placement. Actual output and permitted operating conditions depend on the individual handpiece and motor specifications.

1:1 Direct-Drive Contra-Angle Handpieces

The Kaneiko 1:1 Contra Angle Low Speed Dental Handpiece is designed for controlled restorative, finishing and general chairside procedures.

Its 1:1 transmission maintains the connected motor's rotational speed. Compatible models operate at speeds of up to 40,000 rpm, depending on the motor and rated handpiece limits.

Model C features fibre-optic light transmission and a Black Nano Titanium body, while Model C100 offers a non-optic stainless steel configuration. Both models use internal water spray and accept compatible RA latch-type burs with a 2.35 mm shank.

The Kaneiko 1:1 Surgical Low-Speed Contra-Angle Handpiece provides external water spray for compatible surgical applications. Model CX includes fibre-optic light transmission, while Model CX100 is non-optic.

1:5 Speed-Increasing Contra-Angle Handpieces

Kaneiko 1:5 speed-increasing contra-angle handpieces are designed for high-speed restorative cutting using compatible FG friction-grip burs.

The 1:5 mechanism multiplies motor rotation by five times. A compatible motor operating at 40,000 rpm can theoretically produce 200,000 rpm at the handpiece output, provided the handpiece is rated for that speed.

These handpieces support crown preparation, cavity preparation, veneer preparation, tooth reduction and removal of existing restorations.

Compatible dental air motors may be used when their connection, output characteristics and operating limits meet the selected handpiece specifications. Appropriate water cooling and secure bur retention are essential for safe clinical operation.

1:4.2 Surgical Speed-Increasing Contra-Angle Handpieces

Kaneiko 1:4.2 surgical speed-increasing contra-angle handpieces are designed specifically for oral surgical procedures requiring controlled high-speed cutting and improved access to the operative area.

The 1:4.2 transmission increases compatible motor speed by 4.2 times. Its 45-degree head provides an angled working position for approved surgical cutting and tooth sectioning procedures.

This model is intended for oral surgical applications only and requires compatible surgical burs and appropriate irrigation.

It is not intended for routine crown preparation, cavity preparation, veneer preparation or composite finishing.

20:1 Implant Reduction Contra-Angle Handpieces

Kaneiko 20:1 implant contra-angle handpieces are designed for controlled low-speed rotation and torque transmission during compatible dental implant procedures.

The reduction mechanism decreases input speed by a factor of twenty while increasing available output torque. For example, 40,000 rpm at the motor corresponds to approximately 2,000 rpm at the handpiece output under the nominal transmission ratio.

These handpieces support implant osteotomy preparation, sequential drilling and implant placement using suitable implant drills and drivers.

Although the handpiece may connect mechanically to a compatible dental air motor, implant drilling and placement require an appropriately controlled surgical system. Always follow the implant manufacturer's speed, torque and irrigation protocol.

4:1 Reciprocating Contra-Angle Handpieces for IPR Strips

Kaneiko 4:1 reciprocating contra-angle handpieces are designed exclusively for orthodontic interproximal reduction using compatible IPR strips.

The reciprocating mechanism produces controlled back-and-forth strip movement instead of conventional continuous rotary cutting.

This configuration supports planned interproximal enamel reduction during clear aligner and fixed orthodontic treatment.

The 4:1 reciprocating handpiece is intended only for compatible IPR strips. It is not designed for rotary FG burs, RA burs, polishing attachments or general restorative cutting.

Clinical Benefits

Procedure-Specific Transmission Ratios
Different gear ratios provide appropriate operating characteristics for restorative, orthodontic and surgical applications.

Improved Intraoral Access
The angled head design supports access to posterior teeth and confined treatment areas.

Controlled Low-Speed Performance
The 1:1 configuration supports caries removal, finishing and restorative adjustments.

Efficient High-Speed Preparation
The 1:5 configuration supports crown, cavity and veneer preparation using compatible FG burs.

Dedicated Surgical Design
The 1:4.2 surgical handpiece provides a 45-degree head for selected oral surgical procedures.

Implant Torque Control
The 20:1 reduction configuration supports implant procedures when used with an appropriate surgical motor system.

Orthodontic IPR Precision
The 4:1 reciprocating handpiece supports controlled interproximal reduction using compatible IPR strips.

Buying Considerations

  • Select the correct transmission ratio for the intended procedure
  • Confirm compatibility with the dental air motor
  • Check permitted operating speed and required torque
  • Verify instrument type and retention system
  • Use 1:4.2 models only for approved surgical applications
  • Use 4:1 reciprocating models only with compatible IPR strips
  • Confirm surgical motor suitability for implant procedures
  • Check irrigation requirements and cooling configuration
  • Consider fibre-optic illumination when required
  • Review cleaning, lubrication and sterilisation instructions

The appropriate handpiece should be selected according to clinical procedure, motor performance, instrument compatibility and operating requirements rather than rotational speed alone.

How to Choose the Right Contra-Angle Handpiece

For General Restorative Procedures
Choose a 1:1 direct-drive contra-angle for low-speed caries removal, composite finishing and restorative adjustment.

For Crown and Cavity Preparation
Choose a 1:5 speed-increasing contra-angle for high-speed restorative cutting using suitable FG burs.

For Oral Surgical Procedures
Choose the 1:4.2 surgical contra-angle for its approved cutting and tooth sectioning applications.

For Implant Surgery
Choose a 20:1 reduction contra-angle with a surgical motor system capable of providing the required speed and torque control.

For Orthodontic IPR
Choose the 4:1 reciprocating contra-angle for compatible IPR strips only.

Dental Bur and Instrument Compatibility

Contra-angle handpieces require instruments that match their retention mechanism, operating movement and clinical application.

RA / CA Burs
Compatible 1:1 handpieces typically use latch-type RA burs with a standard 2.35 mm shank.

FG Burs
Compatible 1:5 speed-increasing handpieces use friction-grip burs for high-speed restorative preparation.

Surgical Burs
The 1:4.2 surgical handpiece requires approved surgical cutting instruments.

Implant Drills and Drivers
The 20:1 handpiece requires compatible instruments selected according to the implant system.

IPR Strips
The 4:1 reciprocating handpiece is designed only for compatible IPR strips.

Learn more in the FG, RA and HP Bur Compatibility Guide for Dental Handpieces .

Internal vs External Water Spray

Cooling and irrigation requirements depend on the handpiece design and intended procedure.

Internal Water Spray
Internal irrigation channels deliver water through selected restorative handpieces toward the bur and preparation area.

External Water Spray
Selected surgical configurations use external spray pipes or nozzles to direct irrigation toward the operative site.

Surgical Irrigation
The 1:4.2 surgical handpiece requires appropriate cooling for its approved surgical procedures.

Implant Irrigation
Implant osteotomy preparation requires suitable irrigation according to the implant manufacturer's protocol.

Always inspect the irrigation pathway before treatment and confirm that cooling reaches the working instrument.

Fibre-Optic and Non-Optic Options

Selected Kaneiko contra-angle handpieces are available with fibre-optic light transmission, helping clinicians maintain visibility during compatible restorative and surgical procedures.

Fibre-optic models require a compatible motor or connection system with light transmission capability. Non-optic versions are suitable for clinical setups using external operatory lighting.

Motor Compatibility

Kaneiko contra-angle handpieces, including 1:1, 1:5, 1:4.2, 20:1 and 4:1 models, are designed for use with compatible dental air motors, subject to their individual connection and operating specifications.

1:1 Direct-Drive Models
Compatible dental air motors provide rotational input for low-speed restorative and finishing procedures.

1:5 Speed-Increasing Models
Compatible dental air motors may drive the speed-increasing transmission when the input speed, connection and cooling conditions meet the handpiece specifications.

1:4.2 Surgical Models
Suitable dental air motors may provide input rotation for approved surgical applications when the operating conditions are met.

20:1 Implant Models
Mechanical connection to a dental air motor may be possible, but implant placement requires an appropriate system with controlled speed, torque and irrigation. A standard air motor should not be assumed clinically suitable.

4:1 Reciprocating Models
Compatible dental air motors can drive the reciprocating mechanism for approved IPR strip procedures.

Before use, confirm motor connection, permitted input speed, torque requirements, irrigation and instrument compatibility.

Maintenance and Sterilisation

Proper handpiece maintenance supports smooth operation, secure instrument retention and reliable clinical performance.

After treatment, remove the bur or IPR strip, clean the exterior and inspect the head and irrigation pathway according to the manufacturer's instructions.

Lubricate through the designated port when required and follow the approved sterilisation cycle for the individual model.

Unusual noise, vibration, overheating or reduced performance may indicate that cleaning, lubrication or servicing is necessary.

For additional guidance, read the Kaneiko Dental Handpiece Maintenance Guide .

Professional Insight

In clinical practice, contra-angle selection should begin with the procedure rather than simply choosing the highest available rotational speed.

The 1:1 configuration provides controlled low-speed rotation for restorative finishing. The 1:5 model is intended for high-speed restorative preparation, while the 1:4.2 model serves dedicated surgical cutting applications.

The 20:1 reduction configuration supports implant procedures with appropriate surgical torque control, whereas the 4:1 reciprocating model is restricted to compatible orthodontic IPR strips.

Although compatible dental air motors may be used across the collection, the handpieces are not interchangeable. Motor capability, operating limits, instrument compatibility and irrigation must be considered for each model.

Benefits of Using Kaneiko Contra-Angle Handpieces

  • Multiple transmission ratios for specific clinical applications
  • Controlled low-speed caries removal and restorative finishing
  • High-speed crown and cavity preparation with 1:5 models
  • Dedicated surgical cutting configurations with 1:4.2 models
  • Controlled implant drilling and placement with 20:1 reduction
  • Reciprocating IPR strip operation with 4:1 models
  • Improved access to posterior and confined treatment areas
  • Model-specific bur retention and instrument compatibility
  • Internal and external irrigation configurations on selected models
  • Compatibility with suitable dental air motors

Frequently Asked Questions

1. What is a contra-angle dental handpiece?
A contra-angle handpiece is a dental instrument with an angled working head designed to improve intraoral access during restorative, orthodontic and surgical procedures.

2. What is the difference between 1:1 and 1:5 contra-angle handpieces?
A 1:1 handpiece maintains motor speed, while a 1:5 handpiece multiplies motor speed by five times for compatible high-speed restorative cutting.

3. What is a 1:4.2 surgical contra-angle used for?
It is intended for approved oral surgical cutting and tooth sectioning using suitable surgical instruments.

4. Can a 1:4.2 surgical handpiece be used for crown preparation?
No. The Kaneiko 1:4.2 model is intended for approved surgical procedures rather than routine restorative preparation.

5. What is a 20:1 implant contra-angle?
A 20:1 reduction handpiece decreases motor speed while increasing available output torque for compatible implant procedures.

6. What is a 4:1 reciprocating contra-angle used for?
It is designed exclusively for orthodontic interproximal reduction using compatible IPR strips.

7. Can a 4:1 reciprocating handpiece use dental burs?
No. The Kaneiko 4:1 reciprocating model is intended for compatible IPR strips only.

8. Can all contra-angle handpieces use the same burs?
No. Instrument compatibility depends on the handpiece model and retention system. RA, FG, surgical and implant instruments are not automatically interchangeable.

9. Are Kaneiko contra-angle handpieces compatible with dental air motors?
The collection includes models designed for compatible dental air motors, subject to each handpiece's connection, input speed and operating requirements.

10. Can a standard dental air motor be used for implant placement?
Mechanical compatibility alone is insufficient. Implant placement requires an appropriate surgical system with suitable speed, torque and irrigation control.

11. Which contra-angle is suitable for crown preparation?
The 1:5 speed-increasing contra-angle is intended for high-speed restorative procedures using compatible FG burs.

12. Do contra-angle handpieces require water cooling?
Cooling requirements depend on the procedure. Restorative cutting, surgical cutting and implant drilling generally require suitable irrigation.

13. What should be checked before connecting a dental air motor?
Check the mechanical connection, input speed, torque requirements, irrigation and approved instrument compatibility.

14. What is the difference between 1:4.2 and 20:1 handpieces?
The 1:4.2 configuration increases motor speed for surgical cutting, while the 20:1 configuration reduces speed for implant-related procedures.

15. How should contra-angle handpieces be maintained?
Clean, lubricate when required, inspect and sterilise the handpiece according to the individual product instructions.

コントラアングルハンドピースシリーズ

コントラアングルハンドピースについて

Kaneikoの コントラアングルハンドピース は、精密な切削操作、安定した動力伝達、良好な操作性を追求した歯科用ハンドピースです。 角度を設けたヘッド形状により口腔内へのアクセス性を高め、保存修復、歯科矯正、口腔外科などの処置に対応します。

本シリーズには、 等速1:1、増速1:5、外科用増速1:4.2、インプラント用減速20:1、IPR用レシプロ4:1 の各モデルをラインアップしています。 う蝕除去や修復物の仕上げから、支台歯形成、口腔外科処置、インプラント埋入、隣接面エナメル質削合(IPR)まで、処置に応じた機種を選択できます。

各モデルは、接続規格および使用条件に適合する 歯科用エアモーター との組み合わせを想定しています。 機種選択の際には、ギア比、使用器具、入力回転数、注水方式、臨床用途を確認することが重要です。

歯科診療におけるコントラアングルハンドピースの役割

コントラアングルハンドピースは、ヘッド部分に角度を設けた歯科用器具です。 ストレートハンドピースに比べて臼歯部や狭い口腔内へのアクセスがしやすく、処置部位に応じた操作角度を確保できます。

ギア比によって、接続モーターから伝達される回転速度や出力特性が異なります。 等速1:1タイプは入力回転数をそのまま伝達し、 増速1:5タイプは回転数を5倍に増速して支台歯形成などの高速切削に使用します。

外科用増速1:4.2タイプは、入力回転数を4.2倍に増速する口腔外科処置専用モデルです。 45度のヘッド形状により、適応する外科処置で切削部位へのアクセス性を確保します。

インプラント用減速20:1タイプは、回転数を減速してインプラント窩形成や埋入操作に必要なトルク特性を得るために使用します。 レシプロ4:1タイプは、専用IPRストリップを往復運動させる機構を備えています。

それぞれ作動方式と用途が異なるため、臨床処置に適したギア比、器具保持方式、注水条件を確認して選択する必要があります。

コントラアングルハンドピースの主な用途

う蝕除去
等速1:1コントラアングルと適合するRAタイプのバーを使用し、う蝕象牙質の除去を低速でコントロールしながら行います。

クラウン・ブリッジの支台歯形成
増速1:5コントラアングルと適切なFGバーを組み合わせ、支台歯形成や歯質削除などの高速切削に使用します。

窩洞形成
増速1:5タイプは、保存修復処置におけるエナメル質・象牙質の切削や窩洞形成に対応します。

コンポジットレジンの形態修正・仕上げ
等速1:1タイプと適合する仕上げ用バーを使用し、修復物の形態修正や咬合調整を行います。

ラミネートベニア形成
増速1:5タイプと適切なFGダイヤモンドバーを組み合わせ、エナメル質の切削やベニア形成に使用します。

口腔外科処置・歯牙分割
外科用増速1:4.2タイプは、適合する外科用バーを使用した口腔外科領域の切削や歯牙分割に使用する専用モデルです。

インプラント外科
減速20:1コントラアングルは、適切な回転数・トルク制御が可能なシステムと組み合わせ、インプラント窩形成や埋入に使用します。

矯正治療におけるIPR
レシプロ4:1タイプは適合するIPRストリップ専用です。往復運動により、矯正治療計画に基づく隣接面エナメル質削合を行います。

修復物辺縁部の仕上げ
等速1:1タイプと適合するRAタイプの仕上げ用バーを使用し、修復物辺縁部の調整や研磨前の形態修正に対応します。

Kaneikoコントラアングルハンドピースの設計上の特長

Kaneikoの コントラアングルハンドピースシリーズ は、各診療用途に応じたギア比、器具保持方式、操作性、注水方式を考慮した製品ラインアップです。

主な特長と選択ポイントは以下のとおりです。

  • 等速1:1:低速での修復処置や仕上げに対応
  • 増速1:5:支台歯形成や窩洞形成などの高速切削に対応
  • 外科用増速1:4.2:口腔外科処置専用の増速機構
  • 45度ヘッド:適応する外科処置におけるアクセス性を考慮
  • 減速20:1:インプラント窩形成・埋入操作向け
  • レシプロ4:1:適合するIPRストリップ専用の往復運動機構
  • 機種に応じたRAバー、FGバー、外科用バー、インプラント器具への対応
  • 機種別の内部注水・外部注水システム
  • 一部モデルにライト対応・非ライト対応仕様を用意
  • 規格と使用条件が適合する歯科用エアモーターに対応

処置内容とモーター性能を確認し、適切なハンドピースと使用器具を組み合わせることが重要です。

コントラアングルハンドピースのギア比比較

比較項目 1:1 1:5 1:4.2 20:1 4:1
タイプ 等速タイプ 増速タイプ 外科用増速タイプ インプラント用減速タイプ IPR用レシプロタイプ
ギア比 1:1 1:5 1:4.2 20:1 4:1
回転伝達 入力回転数と同じ 入力回転数の5倍 入力回転数の4.2倍 入力回転数の1/20 4:1減速・往復運動出力
作動方式 連続回転 連続回転 連続回転 連続回転 往復運動
対応器具 RA / CAバー FGバー 適合する外科用バー インプラント用ドリル・ドライバー IPRストリップのみ
主な用途 う蝕除去・修復物の仕上げ 支台歯形成・窩洞形成 口腔外科処置専用 インプラント外科 矯正IPR専用
モーター適合性 適合する歯科用エアモーター 適合する歯科用エアモーター 適合する歯科用エアモーター 適合する歯科用エアモーター* 適合する歯科用エアモーター

*インプラント処置では、専用の速度・トルク制御および適切な注水機能が必要です。機械的に接続できることだけでは、インプラント埋入に使用できるとは限りません。実際の使用条件は各製品の仕様に従ってください。

等速1:1コントラアングルハンドピース

Kaneiko 1:1低速コントラアングルハンドピース は、う蝕除去、修復物の形態修正、仕上げ、一般的なチェアサイド処置に適したモデルです。

1:1の等速伝達機構により、モーターの入力回転数を増減速せずにバーへ伝達します。対応機種では、接続モーターおよび製品の許容条件に応じて最大40,000 rpmまで使用できます。

Model Cは光伝達機能とブラックナノチタンボディを備え、Model C100はライト非対応のステンレス製モデルです。いずれも内部注水方式を採用し、軸径2.35 mmの適合するRAタイプバーを使用します。

外科用途には、 1:1外科用低速コントラアングルハンドピース をラインアップしています。Model CXは光伝達機能を備え、Model CX100はライト非対応仕様です。両モデルとも外部注水方式を採用しています。

増速1:5コントラアングルハンドピース

Kaneikoの増速1:5コントラアングルハンドピースは、適合するFGバーを使用した高速切削を目的とするモデルです。

入力回転数を5倍に増速する機構を備え、例えば40,000 rpmの適合モーターを使用した場合、理論上の出力回転数は200,000 rpmとなります。ただし、実際の使用ではハンドピースの許容最高回転数を超えないようにしてください。

支台歯形成、窩洞形成、ラミネートベニア形成、歯質削除、既存修復物の除去などに対応します。

接続規格、入力回転数、出力特性、注水条件が適合する場合、対応する歯科用エアモーターを使用できます。切削時には適切な冷却とバーの確実な保持が重要です。

外科用増速1:4.2コントラアングルハンドピース

Kaneikoの外科用増速1:4.2コントラアングルハンドピースは、口腔外科領域における切削処置を目的とした専用モデルです。

入力回転数を4.2倍に増速する機構と45度のヘッド形状を備え、適応する外科用切削処置や歯牙分割に使用します。

本モデルは口腔外科処置専用です。製品仕様に適合する外科用バーおよび適切な注水システムを使用してください。

一般的な支台歯形成、窩洞形成、ラミネートベニア形成、コンポジットレジンの仕上げなどの保存修復処置を目的とした製品ではありません。

インプラント用減速20:1コントラアングルハンドピース

Kaneikoのインプラント用減速20:1コントラアングルハンドピースは、インプラント外科に必要な低速回転とトルク伝達を目的としたモデルです。

20:1の減速機構により、入力回転数を1/20に減速し、利用可能な出力トルクを高めます。例えばモーター入力が40,000 rpmの場合、公称ギア比に基づく出力回転数は約2,000 rpmです。

適合するインプラント用ドリルやドライバーと組み合わせ、インプラント窩形成、段階的なドリリング、埋入操作などに使用します。

歯科用エアモーターと機械的に接続できる場合でも、インプラント外科には適切な回転数・トルク制御が可能なシステムが必要です。使用するインプラントシステムの術式、注水条件、推奨設定を必ず確認してください。

IPRストリップ専用レシプロ4:1コントラアングルハンドピース

Kaneikoのレシプロ4:1コントラアングルハンドピースは、歯科矯正における IPR(隣接面エナメル質削合) 専用モデルです。

専用の往復運動機構により、適合するIPRストリップを前後に動かし、隣接面のエナメル質削合を行います。通常の回転切削とは異なる作動方式です。

マウスピース型矯正装置やマルチブラケット装置による矯正治療において、治療計画に基づくIPR処置に使用します。

本モデルは適合するIPRストリップのみに対応します。FGバー、RAバー、研磨用アタッチメント、一般的な回転切削器具には使用できません。

臨床上の特長

処置に応じたギア比の選択
等速、増速、減速、レシプロ方式から、臨床目的に適した作動方式を選択できます。

口腔内へのアクセス性
アングルヘッドにより、臼歯部や狭い処置部位への器具の位置付けをサポートします。

低速での操作性
等速1:1タイプは、う蝕除去や修復物の仕上げなどに対応します。

高速での歯質切削
増速1:5タイプは、支台歯形成や窩洞形成などに適した高速切削を提供します。

口腔外科専用設計
外科用増速1:4.2タイプは、45度ヘッドを備えた外科処置専用モデルです。

インプラント処置への対応
減速20:1タイプは、適切な外科用制御システムと組み合わせて使用します。

矯正IPRへの対応
レシプロ4:1タイプは、適合するIPRストリップを用いた隣接面削合に対応します。

購入前の確認事項

  • 処置目的に適したギア比の選択
  • 歯科用エアモーターとの接続規格の確認
  • 許容入力回転数と必要トルクの確認
  • 使用バーやアタッチメントの適合性
  • 1:4.2モデルは承認された外科用途に限定
  • 4:1レシプロモデルは適合するIPRストリップ専用
  • インプラント処置に必要な外科用制御機能の確認
  • 内部注水・外部注水方式の確認
  • ライト対応の必要性
  • 清掃・注油・滅菌方法の確認

製品選択では、最高回転数だけでなく、処置内容、モーター性能、器具保持機構、注水条件を総合的に検討してください。

用途別コントラアングルハンドピースの選び方

一般的な保存修復処置
う蝕除去や修復物の仕上げには、等速1:1タイプが適しています。

支台歯形成・窩洞形成
適切なFGバーを使用する高速切削には、増速1:5タイプを選択します。

口腔外科処置
適応する切削や歯牙分割には、外科用増速1:4.2タイプを使用します。

インプラント外科
インプラント窩形成や埋入操作には、適切な外科用制御システムと組み合わせた減速20:1タイプを選択します。

矯正治療のIPR
適合するIPRストリップを使用する処置には、レシプロ4:1タイプを選択します。

歯科用バーおよび器具の適合性

各コントラアングルハンドピースには、保持機構と作動方式に適合する器具を使用する必要があります。

RA / CAタイプバー
等速1:1タイプでは、軸径2.35 mmのラッチ式RAバーを使用するモデルがあります。

FGタイプバー
増速1:5タイプでは、高速切削用のFGバーを使用します。

外科用バー
外科用増速1:4.2タイプには、製品仕様に適合する外科用切削器具を使用してください。

インプラント用ドリル・ドライバー
減速20:1タイプでは、使用するインプラントシステムおよびハンドピースに適合する器具を選択します。

IPRストリップ
レシプロ4:1タイプは、適合するIPRストリップ専用です。

バーの規格については、 FG・RA・HPバーの適合性ガイド もご参照ください。

内部注水方式と外部注水方式の違い

注水による冷却は、歯質切削や外科処置中に発生する摩擦熱の管理に重要です。

内部注水方式
ハンドピース内部の注水経路から、バーおよび切削部位へ冷却水を供給する方式です。

外部注水方式
外付けの注水ノズルやパイプから処置部位へ冷却水を供給します。外科用モデルの一部に採用されています。

外科処置時の注水
外科用増速1:4.2タイプでは、製品仕様と処置内容に適した注水・冷却を行ってください。

インプラント外科時の注水
インプラント窩形成では、インプラントメーカーの術式に従った適切な注水が必要です。

処置前には注水経路の詰まりやノズル位置を確認し、切削部位に十分な冷却水が届くことを確認してください。

ライト対応モデルと非ライト対応モデル

Kaneikoの一部コントラアングルハンドピースは、光伝達機能を備えたライト対応仕様です。処置部位の視認性向上をサポートします。

光伝達機能を使用するには、対応するモーターや接続システムが必要です。ライト非対応モデルは、診療用照明で十分な視野が確保できる環境に適しています。

歯科用エアモーターとの適合性

Kaneikoの等速1:1、増速1:5、外科用増速1:4.2、インプラント用減速20:1、レシプロ4:1の各モデルは、接続規格および使用条件に適合する歯科用エアモーターとの組み合わせを想定しています。

等速1:1タイプ
適合する歯科用エアモーターから回転を伝達し、低速でのう蝕除去や修復物の仕上げに使用します。

増速1:5タイプ
接続規格、入力回転数、出力特性、注水条件が製品仕様に適合するエアモーターを使用できます。

外科用増速1:4.2タイプ
製品の入力回転数や注水条件を満たすエアモーターと組み合わせ、適応する外科処置に使用します。

インプラント用減速20:1タイプ
エアモーターとの機械的接続が可能な場合でも、インプラント埋入には適切な回転数・トルク制御および注水機能を備えたシステムが必要です。

レシプロ4:1タイプ
適合するエアモーターによって往復運動機構を駆動し、専用IPRストリップを使用します。

使用前には、接続規格、許容入力回転数、トルク条件、注水方式、対応器具を必ず確認してください。

メンテナンスと滅菌

適切なメンテナンスは、ハンドピースの円滑な作動、器具の確実な保持、安定した性能維持に重要です。

使用後は、製品の取扱説明書に従ってバーやIPRストリップを取り外し、外装やヘッド部を清掃してください。必要に応じて注水経路も点検します。

注油が必要な機種では、指定された注油口に適切な潤滑剤を使用してください。その後、製品に指定された滅菌条件で滅菌を行います。

異音、振動、過熱、回転性能の低下などが発生した場合は、使用を中止し、清掃・注油・点検または修理の必要性を確認してください。

詳しくは Kaneiko歯科用ハンドピースのメンテナンスガイド をご参照ください。

臨床現場での選択ポイント

コントラアングルハンドピースの選択では、単に最高回転数を比較するのではなく、実施する処置と必要な作動方式を基準に判断することが重要です。

等速1:1タイプは低速での修復処置や仕上げに適し、増速1:5タイプは支台歯形成などの高速切削を目的としています。外科用増速1:4.2タイプは、一般的な保存修復処置ではなく、適合する口腔外科処置に使用します。

減速20:1タイプは、適切な外科用制御システムと組み合わせたインプラント処置向けです。レシプロ4:1タイプは、適合するIPRストリップを使用する矯正処置に限定されます。

同じエアモーター接続規格であっても、各機種の用途や使用条件は異なります。器具の適合性、入力回転数、必要トルク、注水条件を確認してください。

Kaneikoコントラアングルハンドピースのメリット

  • 処置に応じて選べる複数のギア比
  • 等速1:1タイプによる低速でのう蝕除去・仕上げ
  • 増速1:5タイプによる支台歯形成・窩洞形成
  • 外科用増速1:4.2タイプによる専用切削処置
  • 減速20:1タイプによるインプラント外科への対応
  • レシプロ4:1タイプによるIPRストリップの往復運動
  • 臼歯部や狭い口腔内へのアクセス性
  • 機種ごとの器具保持方式と適合性
  • 一部モデルに内部・外部注水方式を用意
  • 適合する歯科用エアモーターとの接続に対応

よくあるご質問(FAQ)

1. コントラアングルハンドピースとは何ですか?
ヘッド部分に角度を設けた歯科用器具です。修復処置、矯正処置、口腔外科処置などで、口腔内へのアクセス性を高める目的で使用します。

2. 等速1:1と増速1:5の違いは何ですか?
等速1:1はモーターの入力回転数をそのまま伝達します。増速1:5は入力回転数を5倍に増速し、高速での歯質切削に使用します。

3. 外科用増速1:4.2はどのような処置に使用しますか?
適合する外科用バーを使用した口腔外科領域の切削や歯牙分割など、承認された外科処置に使用します。

4. 外科用増速1:4.2は支台歯形成に使用できますか?
いいえ。Kaneikoの1:4.2モデルは口腔外科処置専用であり、一般的な支台歯形成や窩洞形成を目的としていません。

5. インプラント用減速20:1とは何ですか?
モーターの入力回転数を1/20に減速し、インプラント窩形成や埋入操作に適した出力特性を得るためのハンドピースです。

6. レシプロ4:1はどのような用途に使用しますか?
適合するIPRストリップを使用した、歯科矯正における隣接面エナメル質削合専用です。

7. レシプロ4:1に歯科用バーを装着できますか?
いいえ。本モデルは専用IPRストリップのみを使用する設計であり、通常の回転切削用バーには対応していません。

8. すべてのコントラアングルで同じバーを使用できますか?
いいえ。RAバー、FGバー、外科用バー、インプラント用器具など、それぞれの機種に適合する器具を使用する必要があります。

9. Kaneikoのコントラアングルは歯科用エアモーターに対応していますか?
各モデルは、適合する歯科用エアモーターとの接続を想定しています。ただし、接続規格、入力回転数、トルク、注水条件は機種によって異なります。

10. 通常の歯科用エアモーターでインプラントを埋入できますか?
機械的に接続できるだけでは十分ではありません。インプラント埋入には、適切な回転数・トルク制御と注水機能を備えたシステムが必要です。

11. 支台歯形成にはどのタイプが適していますか?
適切なFGバーと注水を使用する増速1:5コントラアングルが、高速での支台歯形成に適しています。

12. コントラアングルの使用時には注水が必要ですか?
必要な冷却条件は機種と処置内容によって異なります。歯質切削や外科切削、インプラント窩形成では、適切な注水が重要です。

13. エアモーター接続前に確認することは何ですか?
接続規格、許容入力回転数、必要トルク、注水方式、使用器具の適合性を確認してください。

14. 外科用増速1:4.2とインプラント用減速20:1の違いは何ですか?
1:4.2は外科切削のために回転数を増速するモデルです。20:1はインプラント処置のために回転数を減速し、出力トルクを高めるモデルです。

15. コントラアングルハンドピースのメンテナンス方法は?
使用後は器具を取り外し、製品の取扱説明書に従って清掃、必要な注油、点検、滅菌を行ってください。