Model I20L 20:1 Implant Surgical Speed-Reducing Electric Contra-Angle Handpiece
Kaneiko Model I20L 20:1 Implant Surgical Speed-Reducing Electric Contra-Angle Handpiece
The Kaneiko Model I20L 20:1 implant surgical contra-angle handpiece is designed for controlled low-speed operation during dental implant and compatible oral surgery procedures. Its 20:1 speed-reducing transmission converts the speed of a compatible implant motor into a maximum output speed of up to 2,000 rpm, supporting controlled drilling and implant placement. The handpiece features fibre-optic light transmission, a ceramic bearing, single-point external water spray and a Black Nano Titanium body. It accepts RA latch-type burs and implant instruments with a standard Ø 2.35 mm shank.
What’s Included
- Kaneiko Handpiece in pacakging box
- Manual guide book
- Maintenance Cleaning Kit (Nozzle + Needle)
- Head Cap Spanner
Characteristics
- 20:1 speed-reducing transmission
- Maximum output speed up to 2,000 rpm
- Designed for compatible implant motors
- Fibre-optic light transmission
- Ceramic bearing for stable rotation
- Single-point external water spray
- Black Nano Titanium body
- RA latch-type bur compatibility
- Ø 2.35 mm instrument shank compatibility
- Clean head system
- Anti-heat system
- Suitable for implant surgical procedures
Technical Specifications
| Specification | Details |
|---|---|
| Model | I20L |
| Handpiece Type | Implant Surgical Speed-Reducing Electric Contra-Angle Handpiece |
| Transmission Ratio | 20:1 Speed Reducing |
| Maximum Rotation | Up to 2,000 min⁻¹, implant motor dependent |
| Bearing | Ceramic Bearing |
| Light Transmission | Fibre Optic |
| Water Spray | Single-Point External Water Spray |
| Body Material | Black Nano Titanium |
| Bur Type | RA Latch-Type Burs and Compatible Implant Instruments |
| Instrument Shank Diameter | Ø 2.35 mm |
| Motor Compatibility | Compatible Electric Implant Motor |
| Application | Implant and Surgical Use |
| Protective Features | Clean Head System and Anti-Heat System |
20:1 Speed-Reducing Transmission
The 20:1 transmission reduces the rotational speed supplied by a compatible electric implant motor while supporting controlled torque delivery. The handpiece operates at speeds of up to 2,000 rpm, making it suitable for implant drilling, osteotomy preparation and controlled implant placement according to the selected surgical protocol.
Designed for Implant Surgical Procedures
The Kaneiko Model I20L is designed for use with a compatible electric implant motor during dental implant and compatible oral surgery procedures. Its reduced-speed transmission supports controlled instrument movement during sequential drilling, implant-site preparation and implant insertion.
Single-Point External Water Spray
The single-point external water spray directs irrigation toward the working instrument and surgical area. This supports cooling and debris removal during compatible implant drilling procedures. Confirm that the external irrigation line is correctly positioned before operating the handpiece.
Fibre-Optic Light Transmission
Fibre-optic light transmission carries illumination from a compatible implant motor toward the treatment area. Improved visibility supports controlled instrument positioning during implant-site preparation and surgical procedures, particularly in posterior or restricted areas.
Ceramic Bearing
The ceramic bearing supports smooth and stable rotation during low-speed implant procedures. This helps reduce vibration and supports controlled handling when preparing the implant site or using compatible surgical instruments.
Black Nano Titanium Body
The Black Nano Titanium body provides a durable and premium handpiece surface designed for regular clinical handling. Its ergonomic form supports controlled positioning during implant and surgical procedures.
Clean Head and Anti-Heat Systems
The clean head system helps reduce the entry of treatment debris into the handpiece head, while the anti-heat system supports controlled temperature management during operation. The handpiece should be cleaned, lubricated and sterilised according to the recommended maintenance instructions.
Implant Motor Compatibility
The I20L implant contra-angle handpiece is designed for connection to a compatible electric implant motor. Before use, confirm that the motor connection, fibre-optic system, irrigation configuration and programmed speed settings are suitable for the selected surgical procedure.
Bur and Instrument Compatibility
- RA latch-type burs and compatible implant surgical instruments
- Standard instrument shank diameter: Ø 2.35 mm
- Use instruments approved for the selected speed and surgical procedure
- Confirm that the instrument is fully inserted and securely retained before operation
- Follow the implant system manufacturer’s recommended drilling sequence
Recommended Clinical Applications
- Dental implant osteotomy preparation
- Sequential implant drilling
- Implant-site preparation
- Controlled implant placement
- Implant insertion with compatible instruments
- Compatible oral surgery procedures
- Low-speed surgical drilling