1:5 Electric Contra-Angle Handpiece
Explore Kaneiko 1:5 electric speed-increasing contra-angle handpieces engineered to increase motor speed by five times, reaching up to 200,000 rpm. Compatible with FG friction-grip burs, these electric high-speed handpieces support crown preparation, cavity preparation, tooth reduction and removal of existing restorations with controlled cutting, effective water cooling and smooth clinical performance.
1:5 Electric Contra-Angle Handpiece Series
More About 1:5 Electric Contra-Angle Handpieces
Kaneiko 1:5 electric contra-angle handpieces are speed-increasing rotary instruments designed for high-speed crown preparation, cavity preparation, restorative material removal and prosthodontic procedures. Their 1:5 gear transmission multiplies the speed produced by a compatible electric micromotor by five, providing controlled high-speed cutting with FG friction-grip burs.
Unlike an air turbine handpiece, a 1:5 electric contra-angle is driven by an electric micromotor. This system provides stable rotational performance and controlled power delivery across different cutting loads, making it suitable for clinicians who prefer an electric high-speed handpiece for routine restorative workflows.
The Kaneiko collection includes the 1:5 Speed-Increasing Electric Contra-Angle Handpiece for FG Burs in two configurations. Model EB1L features three-point internal water spray for chairside and general use, while Model E1L-X features single-point external water spray for compatible motor and MOS setups.
Both models accept FG dental burs with a standard Ø1.6 mm shank and include fibre-optic light transmission, ceramic bearings, a push-button chuck, Clean Head System and Anti-Heat System.
Introducing 1:5 Electric Contra-Angle Handpieces in Clinical Dentistry
A 1:5 electric contra-angle handpiece is used when high rotational speed is required from an electric micromotor system. The internal gear mechanism multiplies the motor input speed, allowing the handpiece to perform procedures commonly completed with high-speed FG burs.
The Kaneiko handpiece has a specified maximum micromotor input speed of 33,000 rpm. At this input speed, the 1:5 transmission produces a nominal maximum bur speed of approximately 165,000 rpm. The motor input limit should not be exceeded.
Electric contra-angle systems are valued for their controlled speed delivery and stable cutting performance. Their angled head also supports intraoral access during crown preparation, cavity preparation and restorative adjustment, particularly in posterior treatment areas.
Clinical performance depends on more than the gear ratio. Bearing stability, water spray coverage, bur retention, motor compatibility, illumination and correct operating speed all influence cutting efficiency and long-term reliability.
What Are 1:5 Electric Contra-Angle Handpieces Used For?
Crown and Bridge Preparation
Supports anatomical tooth reduction, axial preparation, occlusal clearance and margin development using suitable FG diamond burs.
Cavity Preparation
Provides controlled high-speed rotation for cavity access, caries removal and preparation of tooth structure for restorative treatment.
Removal of Existing Restorations
Suitable for cutting and removing composite, temporary restorative materials and selected existing restorations with compatible FG burs.
Veneer Preparation
Supports controlled enamel reduction, depth-guided preparation and refinement of veneer margins.
Inlay and Onlay Preparation
Used for cavity refinement, wall preparation, margin finishing and removal of unsupported tooth structure.
Restoration Contouring and Adjustment
Provides stable FG bur rotation for adjusting restorative contours and refining preparation surfaces.
Preparation Margin Refinement
Supports precise finishing of crown, veneer, inlay and onlay preparation margins.
Kaneiko 1:5 Electric Contra-Angle Handpieces: Engineered for Controlled High-Speed Cutting
Kaneiko speed-increasing electric contra-angle handpieces are designed around the clinical requirements of electric high-speed preparation: stable gear transmission, effective water cooling, clear illumination and secure FG bur retention.
Key design priorities include:
- 1:5 speed-increasing gear transmission
- Maximum micromotor input speed of 33,000 rpm
- Nominal bur speed of up to approximately 165,000 rpm
- FG friction-grip bur compatibility
- Standard Ø1.6 mm bur shank acceptance
- Fibre-optic light transmission
- Ceramic bearings for stable rotation
- Push-button bur changing system
- Internal and external water spray options
- Clean Head and Anti-Heat Systems
These features support controlled preparation while allowing clinics to select the water-delivery system and body configuration that best match their electric micromotor setup.
Model Comparison
| Feature | Model EB1L | Model E1L-X |
|---|---|---|
| Transmission Ratio | 1:5 Speed Increasing | 1:5 Speed Increasing |
| Maximum Motor Input | 33,000 rpm, Do Not Exceed | 33,000 rpm, Do Not Exceed |
| Nominal Maximum Bur Speed | Approximately 165,000 rpm | Approximately 165,000 rpm |
| Light Transmission | Fibre Optic | Fibre Optic |
| Water Spray | Three-Point Internal Water Spray | Single-Point External Water Spray |
| Body Material | Black Nano Titanium | Stainless Steel |
| Bearing | Ceramic Bearing | Ceramic Bearing |
| Chuck System | Push Button | Push Button |
| Bur Compatibility | FG Burs, Ø1.6 mm | FG Burs, Ø1.6 mm |
| Protective Features | Clean Head and Anti-Heat Systems | Clean Head and Anti-Heat Systems |
| Recommended Application | Chairside and General Use | Motor and MOS Use |
Model EB1L with Three-Point Internal Water Spray
Model EB1L is designed for chairside and general restorative use. Its three-point internal water spray delivers cooling water through channels inside the contra-angle handpiece and distributes it around the FG bur.
The integrated water pathway supports consistent cooling, debris removal and visibility without requiring an external spray pipe. This creates a cleaner chairside configuration for crown preparation, cavity preparation and routine restorative procedures.
Model EB1L features a Black Nano Titanium body, fibre-optic light transmission, ceramic bearing, push-button chuck, Clean Head System and Anti-Heat System.
Model E1L-X with Single-Point External Water Spray
Model E1L-X uses a single-point external water spray pipe that directs cooling water toward the FG bur and preparation surface. This version is intended for compatible motor and MOS setups requiring an external water-delivery configuration.
The position of the external spray pipe should be checked before operation to confirm that cooling water reaches the working end of the bur effectively.
Model E1L-X features a stainless steel body, fibre-optic light transmission, ceramic bearing, push-button chuck, Clean Head System and Anti-Heat System.
Clinical Benefits
Controlled Electric Cutting Performance
The 1:5 transmission converts electric micromotor speed into high-speed FG bur rotation for restorative and prosthodontic preparation.
Stable Rotation Under Cutting Load
Electric micromotor drive and ceramic bearings support smooth and controlled bur movement across different preparation tasks.
Internal and External Cooling Options
Clinicians can select three-point internal spray or single-point external spray according to the intended motor and water-delivery setup.
Fibre-Optic Visibility
Light transmission from a compatible electric micromotor supports visibility around the bur and preparation margin.
Convenient Bur Changes
The push-button chuck allows FG burs to be inserted and removed without a separate bur-changing tool.
Versatile Restorative Applications
Suitable for crown preparation, cavity preparation, veneers, inlays, onlays and removal of restorative materials.
Buying Considerations
- Confirm compatibility with the intended electric micromotor
- Do not exceed the maximum micromotor input speed of 33,000 rpm
- Select internal or external water spray according to the clinical setup
- Confirm that the micromotor supports fibre-optic light transmission
- Use only FG burs with a standard Ø1.6 mm shank
- Choose burs approved for the selected output speed
- Check the connection and water-delivery configuration before purchase
- Consider body material, handling balance and maintenance requirements
- Confirm access to replacement rotors, cartridges and servicing support
The correct model should be selected according to the electric micromotor system and irrigation configuration rather than appearance alone.
How to Choose the Right 1:5 Electric Contra-Angle Handpiece
Choose Model EB1L for Internal Water Delivery
Select EB1L for chairside and general use when the electric system supports internal water delivery through the handpiece.
Choose Model E1L-X for External Water Delivery
Select E1L-X for compatible motor and MOS setups where an external spray pipe is required.
Confirm Electric Micromotor Compatibility
Check the physical connection, maximum motor speed, fibre-optic capability and water-delivery system before ordering.
Confirm the Required Clinical Procedure
A 1:5 electric contra-angle is suitable for high-speed restorative and prosthodontic preparation. It is not a substitute for a 20:1 implant contra-angle used for implant placement.
Select the Correct FG Bur
Use a compatible Ø1.6 mm FG diamond or carbide bur approved for the required rotational speed and clinical application.
Important Motor Speed Limit
The Kaneiko 1:5 electric contra-angle handpiece must not be operated with a micromotor input speed above 33,000 rpm.
The gear system multiplies the motor input speed by five. At 30,000 rpm motor input, the nominal bur speed is approximately 150,000 rpm. At the maximum permitted input of 33,000 rpm, the nominal bur speed is approximately 165,000 rpm.
Operating the micromotor above the specified limit may exceed the recommended operating range of the contra-angle handpiece. Confirm the motor setting before each procedure.
FG Bur Compatibility
Model EB1L and Model E1L-X accept FG friction-grip burs with a standard Ø1.6 mm shank. FG burs are commonly available in diamond and carbide configurations for crown preparation, cavity preparation, restoration removal and finishing.
FG burs should not be confused with Ø2.35 mm RA latch-type burs used in 1:1 low-speed contra-angle handpieces or HP burs used in straight handpieces.
To understand the differences between rotary-instrument systems, read the FG, RA and HP Bur Compatibility Guide for Dental Handpieces .
Always inspect the bur before use. A bent, worn or incorrectly inserted bur may increase vibration, reduce preparation accuracy and place unnecessary stress on the chuck and bearing.
Internal vs External Water Spray
Model EB1L uses three-point internal water spray delivered through the body of the handpiece. Water is distributed around the FG bur from multiple points to support cooling and debris removal.
Model E1L-X uses a single-point external spray pipe. This allows water to be directed toward the bur and preparation area from outside the handpiece body.
The selected water-spray system must match the configuration of the electric micromotor and dental unit. Before treatment, confirm that water reaches the working end of the bur.
Fibre-Optic Light Transmission
Both models feature fibre-optic light transmission. Illumination is carried from a compatible electric micromotor through the handpiece toward the treatment area.
Fibre-optic visibility can support accurate bur positioning, margin preparation and restorative work in posterior or restricted areas. The connected micromotor must support light transmission for this feature to function.
Electric Micromotor Compatibility
A 1:5 speed-increasing contra-angle must be used with a compatible electric micromotor and connection system. Before purchase, verify the connection type, motor speed range, light transmission and water-delivery configuration.
The micromotor should provide controllable speed settings so the maximum input limit of 33,000 rpm can be maintained. The handpiece should not be connected to an incompatible motor or operated beyond its specified range.
Maintenance and Sterilisation
Proper maintenance supports smooth gear transmission, bearing stability, chuck retention and water spray performance. After use, remove the FG bur, clean the handpiece exterior and flush the water pathway according to the product instructions.
Lubricate the handpiece through the correct connection or maintenance adaptor when required. Operate it briefly to distribute the lubricant and remove excess oil before sterilisation.
Inspect the push-button chuck, spray outlets and bearing movement regularly. Increased noise, vibration, heat, reduced speed or loose bur retention may indicate that servicing is required.
Read the Kaneiko Dental Handpiece Maintenance Guide for further cleaning, lubrication, sterilisation and storage guidance.
Professional Insight
In clinical practice, a 1:5 electric contra-angle is selected when dentists want high-speed cutting with the controlled power delivery of an electric micromotor system.
Model selection should begin with the water-delivery configuration. EB1L provides an integrated three-point internal spray for general chairside procedures, while E1L-X provides external irrigation for compatible motor and MOS setups.
The operating limit is equally important. Although many 1:5 handpieces are commonly associated with 200,000 rpm, this Kaneiko model has a specified maximum motor input of 33,000 rpm, producing a nominal maximum output of approximately 165,000 rpm.
Reliable clinical performance also depends on the condition of the FG bur, correct motor setting, adequate cooling and regular maintenance. Excessive pressure should not be used to compensate for a worn bur or poorly maintained handpiece.
Benefits of Using Kaneiko 1:5 Electric Contra-Angle Handpieces
- Deliver controlled high-speed cutting from an electric micromotor
- Support crown, cavity, veneer, inlay and onlay preparation
- Accept standard Ø1.6 mm FG friction-grip burs
- Provide three-point internal or single-point external water spray
- Improve treatment visibility through fibre-optic light transmission
- Support smooth rotation with ceramic bearing systems
- Provide convenient FG bur changes through a push-button chuck
- Offer chairside, general, motor and MOS configurations
- Support stable preparation and restorative material removal
- Provide model options for different electric micromotor setups
Frequently Asked Questions
1. What is a 1:5 electric contra-angle handpiece?
It is a speed-increasing handpiece that multiplies the input speed from a compatible electric micromotor by five.
2. What is the maximum speed of this Kaneiko 1:5 handpiece?
The maximum permitted micromotor input is 33,000 rpm, producing a nominal maximum bur speed of approximately 165,000 rpm.
3. Can I run the motor at 40,000 rpm?
No. The motor input speed for this handpiece must not exceed 33,000 rpm.
4. What burs are compatible with the handpiece?
Model EB1L and Model E1L-X accept FG friction-grip burs with a standard Ø1.6 mm shank.
5. What is the difference between EB1L and E1L-X?
EB1L has a Black Nano Titanium body and three-point internal water spray. E1L-X has a stainless steel body and single-point external water spray.
6. Which model is suitable for general chairside use?
Model EB1L is designed for chairside and general use with internal water delivery.
7. Which model is suitable for external water delivery?
Model E1L-X is designed for compatible motor and MOS setups requiring a single-point external spray.
8. Does the handpiece include fibre-optic illumination?
Yes. Both models transmit light from a compatible fibre-optic electric micromotor toward the treatment area.
9. Can a 1:5 handpiece be used for implant placement?
No. Implant placement normally requires a dedicated 20:1 speed-reducing implant contra-angle and a compatible implant motor with torque control.
10. How should the handpiece be maintained?
Remove the bur, clean the exterior, flush the water pathway, lubricate according to the instructions, inspect the chuck and spray outlets, sterilise correctly and allow the handpiece to dry before storage.
1:5 電動コントラアングルハンドピース
1:5 増速コントラアングルハンドピースについて
Kaneiko 1:5 増速コントラアングルハンドピース は、クラウン形成、窩洞形成、修復材料の除去、 補綴処置など、高速切削が必要な臨床ワークフローのために設計された 増速式の歯科用ハンドピースです。 1:5のギア機構により、対応する電動マイクロモーターの回転数を5倍に増速し、 FGフリクショングリップバーによる コントロールされた高速切削を可能にします。
エアタービン式の高速ハンドピースとは異なり、 1:5 増速コントラアングルは電動マイクロモーターによって駆動されます。 電動システムによる安定した回転とコントロールされた動力伝達により、 異なる切削負荷でも安定した操作をサポートします。
Kaneikoの 1:5 増速電動コントラアングルハンドピース FGバー用 には、2つの仕様があります。 Model EB1Lはチェアサイドおよび一般的な臨床用途向けの 3点内部注水スプレーを採用し、 Model E1L-Xは対応するモーターおよびMOS用途向けの 1点外部注水スプレーを採用しています。
両モデルとも、標準Ø1.6 mmシャンクのFGバーに対応し、 光ファイバー伝送、セラミックベアリング、 プッシュボタンチャック、 クリーンヘッドシステム、 アンチヒートシステムを備えています。
臨床歯科における1:5 増速コントラアングルハンドピース
1:5 増速コントラアングルハンドピースは、 電動マイクロモーターから高速回転を得る必要がある場合に使用されます。 内部のギア機構によってモーターの入力回転数を5倍に増速し、 高速FGバーを使用するさまざまな歯科処置に対応します。
Kaneiko 1:5 増速コントラアングルハンドピースの 最大マイクロモーター入力回転数は 33,000 rpmです。 この入力回転数では、1:5の増速機構により、 バーの公称最大回転数は約 165,000 rpmとなります。 指定された最大モーター入力回転数を超えて使用しないでください。
電動コントラアングルシステムは、 コントロールされた回転速度と 安定した切削性能を提供します。 また、アングルヘッドにより、 クラウン形成、窩洞形成、 修復物の調整などで口腔内へのアクセスをサポートします。
臨床性能はギア比だけで決まるものではありません。 ベアリングの安定性、注水範囲、バーの保持力、 モーターとの適合性、照明、 適切な作動回転数なども、 切削効率と長期的な信頼性に影響します。
1:5 増速コントラアングルハンドピースの主な用途
クラウン・ブリッジ形成
適切なFGダイヤモンドバーを使用して、
解剖学的な歯質削除、軸面形成、咬合面クリアランスの確保、
フィニッシュライン形成をサポートします。
窩洞形成
う蝕除去や修復治療のための歯質形成に、
コントロールされた高速回転を提供します。
既存修復物の除去
対応するFGバーを使用して、
コンポジット、暫間修復材料、
その他の対応する修復物の切削・除去に使用できます。
ベニア形成
エナメル質のコントロールされた削除、
デプスガイド形成、
ベニアマージンの仕上げをサポートします。
インレー・オンレー形成
窩洞の調整、壁面形成、
マージン仕上げ、
不要な歯質の除去などに使用できます。
修復物の形態修正・調整
安定したFGバー回転により、
修復物の形態調整や形成面の仕上げをサポートします。
形成マージンの仕上げ
クラウン、ベニア、インレー、
オンレーなどの形成マージンを
精密に仕上げるために使用できます。
Kaneiko 1:5 増速コントラアングル:コントロールされた高速切削のための設計
Kaneiko 1:5 増速コントラアングルハンドピース は、安定したギア伝達、効果的な注水冷却、 良好な視認性、確実なFGバー保持など、 電動高速形成に必要な臨床要素を考慮して設計されています。
主な設計ポイント:
- 1:5 増速ギア機構
- 最大マイクロモーター入力回転数 33,000 rpm
- 公称最大バー回転数 約165,000 rpm
- FGフリクショングリップバー対応
- 標準Ø1.6 mmバーシャンク対応
- 光ファイバー伝送
- 安定した回転をサポートするセラミックベアリング
- プッシュボタン式バー交換システム
- 内部注水・外部注水スプレー仕様
- クリーンヘッドシステム
- アンチヒートシステム
これらの仕様により、 電動マイクロモーターの構成や注水方式に合わせて 適切なモデルを選択できます。
Model EB1L・E1L-X 比較
| 項目 | Model EB1L | Model E1L-X |
|---|---|---|
| ギア比 | 1:5 増速 | 1:5 増速 |
| 最大モーター入力回転数 |
33,000 rpm ※超過不可 |
33,000 rpm ※超過不可 |
| 公称最大バー回転数 | 約165,000 rpm | 約165,000 rpm |
| 光伝送 | 光ファイバー | 光ファイバー |
| 注水方式 | 3点内部注水スプレー | 1点外部注水スプレー |
| ボディ材質 | ブラックナノチタン | ステンレススチール |
| ベアリング | セラミックベアリング | セラミックベアリング |
| チャックシステム | プッシュボタン | プッシュボタン |
| 対応バー | FGバー Ø1.6 mm | FGバー Ø1.6 mm |
| 保護機構 |
クリーンヘッド アンチヒート |
クリーンヘッド アンチヒート |
| 推奨用途 | チェアサイド・一般臨床 | モーター・MOS用途 |
Model EB1L:3点内部注水スプレー
Model EB1Lは、 チェアサイドおよび一般的な修復処置向けに設計されています。 3点内部注水スプレーにより、 コントラアングル内部のチャンネルから冷却水を供給し、 FGバー周囲へ複数方向から注水します。
一体化された注水経路により、 外部スプレーパイプを使用せずに、 冷却、切削片の除去、視認性をサポートします。 クラウン形成、窩洞形成、 日常的な修復処置に適した構成です。
Model EB1Lは、 ブラックナノチタンボディ、 光ファイバー伝送、 セラミックベアリング、 プッシュボタンチャック、 クリーンヘッドシステム、 アンチヒートシステムを備えています。
Model E1L-X:1点外部注水スプレー
Model E1L-Xは、 FGバーと形成面に向けて冷却水を供給する 1点外部注水スプレーパイプを採用しています。 外部注水構成を必要とする、 対応するモーターおよびMOS用途向けのモデルです。
使用前には外部スプレーパイプの位置を確認し、 冷却水がバーの作業部へ 適切に届いていることを確認してください。
Model E1L-Xは、 ステンレススチールボディ、 光ファイバー伝送、 セラミックベアリング、 プッシュボタンチャック、 クリーンヘッドシステム、 アンチヒートシステムを備えています。
臨床上のメリット
コントロールされた電動高速切削
1:5増速機構により、
電動マイクロモーターの回転数を高速FGバー回転へ変換し、
修復・補綴形成をサポートします。
切削負荷時の安定した回転
電動マイクロモーターとセラミックベアリングにより、
さまざまな形成処置で
スムーズかつコントロールされたバー回転をサポートします。
内部・外部注水の選択
使用するモーターと注水システムに応じて、
3点内部注水または1点外部注水を選択できます。
光ファイバーによる視認性
対応する電動マイクロモーターからの光伝送により、
バー周囲や形成マージンの視認性をサポートします。
スムーズなバー交換
プッシュボタンチャックにより、
専用のバー交換工具を使用せずに
FGバーを着脱できます。
幅広い修復・補綴処置に対応
クラウン形成、窩洞形成、
ベニア、インレー、オンレー形成、
修復材料の除去などに使用できます。
購入前に確認したいポイント
- 使用予定の電動マイクロモーターとの適合性を確認する
- 最大モーター入力回転数33,000 rpmを超えない
- 臨床環境に応じて内部注水または外部注水を選択する
- マイクロモーターが光ファイバー伝送に対応しているか確認する
- 標準Ø1.6 mmシャンクのFGバーのみを使用する
- 使用する回転数に対応したバーを選択する
- 購入前に接続方式と注水システムを確認する
- ボディ材質、操作バランス、メンテナンス条件を確認する
- 交換部品や修理サポートについて確認する
適切なモデルは外観だけでなく、 使用する電動マイクロモーターと 注水システムの構成に合わせて選択することが重要です。
適切な1:5 増速コントラアングルの選び方
内部注水にはModel EB1L
電動システムがハンドピース内部からの注水に対応している場合、
チェアサイドや一般的な臨床用途には
Model EB1Lが適しています。
外部注水にはModel E1L-X
外部スプレーパイプを必要とする
対応モーターやMOS構成では、
Model E1L-Xを選択します。
電動マイクロモーターとの適合性を確認
購入前に接続方式、
最大モーター回転数、
光ファイバー対応、
注水システムを確認してください。
必要な臨床処置を確認
1:5 増速コントラアングルは、
高速での修復・補綴形成に適しています。
インプラント埋入に使用する
20:1減速インプラント用コントラアングルの代替ではありません。
適切なFGバーを選択
必要な回転数と臨床用途に対応した
Ø1.6 mmのFGダイヤモンドバーまたは
FGカーバイドバーを使用してください。
重要:モーター入力回転数の上限
Kaneiko 1:5 増速コントラアングルハンドピースは、 33,000 rpmを超えるマイクロモーター入力回転数で 使用しないでください。
1:5のギア機構は、 モーター入力回転数を5倍に増速します。 モーター入力が30,000 rpmの場合、 公称バー回転数は約150,000 rpmです。 最大許容入力である33,000 rpmの場合、 公称バー回転数は約165,000 rpmとなります。
指定された上限を超えるモーター回転数で使用すると、 コントラアングルハンドピースの 推奨作動範囲を超える可能性があります。 各処置の前にモーター設定を確認してください。
FGバーの適合性
Model EB1LとModel E1L-Xは、 標準Ø1.6 mmシャンクの FG(フリクショングリップ)バーに対応しています。 FGバーにはダイヤモンドやカーバイドなどがあり、 クラウン形成、窩洞形成、 修復物の除去、仕上げなどに使用されます。
FGバーは、 1:1低速コントラアングルで使用する Ø2.35 mmのRAラッチタイプバーや、 ストレートハンドピースで使用するHPバーとは異なります。
FG、RA、HPバーの違いについて詳しくは、 FG・RA・HPバー適合ガイド をご覧ください。
使用前にはバーの状態を確認してください。 曲がったバー、摩耗したバー、 正しく挿入されていないバーは、 振動の増加、形成精度の低下、 チャックやベアリングへの不要な負荷につながる可能性があります。
内部注水と外部注水の違い
Model EB1Lは、 ハンドピース本体内部を通る 3点内部注水スプレーを採用しています。 複数方向からFGバー周囲へ注水することで、 冷却と切削片の除去をサポートします。
Model E1L-Xは、 1点外部注水スプレーパイプを採用しています。 ハンドピース本体の外側から、 バーと形成部位に向けて冷却水を供給します。
選択する注水方式は、 電動マイクロモーターおよび歯科ユニットの構成と 適合している必要があります。 治療前に冷却水がバーの作業部まで 適切に届いていることを確認してください。
光ファイバー伝送
Model EB1LとModel E1L-Xの両モデルとも、 光ファイバー伝送に対応しています。 対応する電動マイクロモーターからの光を ハンドピースを通して治療部位へ伝送します。
光ファイバーによる照明は、 臼歯部やアクセスが制限される部位での バー位置の確認、マージン形成、 修復処置の視認性をサポートします。 この機能を使用するには、 接続するマイクロモーターも 光伝送に対応している必要があります。
電動マイクロモーターとの適合性
1:5 増速コントラアングルは、 対応する電動マイクロモーターおよび 接続システムと組み合わせて使用する必要があります。 購入前に、接続方式、モーター回転数、 光伝送、注水方式を確認してください。
マイクロモーターは、 最大入力回転数33,000 rpmを維持できるよう、 回転数を適切にコントロールできる必要があります。 適合しないモーターへの接続や、 指定範囲を超える回転数での使用は避けてください。
メンテナンスと滅菌
適切なメンテナンスは、 スムーズなギア伝達、 ベアリングの安定性、 チャックの保持力、 注水性能を維持するために重要です。
使用後はFGバーを取り外し、 ハンドピース外面を清掃し、 製品の取扱説明書に従って 注水経路をフラッシュしてください。
必要に応じて、 正しい接続部またはメンテナンスアダプターから注油してください。 潤滑油を内部へ行き渡らせるために短時間作動させ、 滅菌前に余分なオイルを除去します。
プッシュボタンチャック、 スプレー孔、 ベアリングの動きを定期的に確認してください。 騒音、振動、発熱の増加、 回転数の低下、 バー保持力の低下が見られる場合は、 メンテナンスや修理が必要な可能性があります。
清掃、注油、滅菌、保管について詳しくは、 Kaneiko 歯科用ハンドピース メンテナンスガイド をご覧ください。
プロフェッショナル向けポイント
臨床では、 1:5 増速コントラアングルは、 電動マイクロモーターによる コントロールされた動力伝達と高速切削を 組み合わせたい場合に選択されます。
モデルを選択する際には、 まず注水方式を確認することが重要です。 EB1Lは一般的なチェアサイド処置向けの 3点内部注水を備え、 E1L-Xは対応するモーター・MOS構成向けの 外部注水を備えています。
作動回転数の上限も重要です。 1:5ハンドピースは一般的に200,000 rpmと 関連付けられる場合がありますが、 このKaneikoモデルの指定最大モーター入力回転数は 33,000 rpmであり、 公称最大出力は約 165,000 rpmです。
安定した臨床性能を維持するためには、 FGバーの状態、正しいモーター設定、 十分な冷却、 定期的なメンテナンスも重要です。 摩耗したバーやメンテナンス不足を補うために、 過度な切削圧をかけないでください。
Kaneiko 1:5 増速コントラアングルハンドピースのメリット
- 電動マイクロモーターによるコントロールされた高速切削
- クラウン、窩洞、ベニア、インレー、オンレー形成をサポート
- 標準Ø1.6 mm FGフリクショングリップバーに対応
- 3点内部注水または1点外部注水を選択可能
- 光ファイバー伝送により治療部位の視認性をサポート
- セラミックベアリングによるスムーズな回転
- プッシュボタンチャックによるスムーズなFGバー交換
- チェアサイド、一般臨床、モーター・MOS用途に対応
- 安定した歯牙形成と修復材料の除去をサポート
- 異なる電動マイクロモーター構成に対応するモデルを用意
よくあるご質問
1. 1:5 増速コントラアングルハンドピースとは何ですか?
対応する電動マイクロモーターの入力回転数を
5倍に増速する歯科用ハンドピースです。
2. Kaneiko 1:5 ハンドピースの最大回転数はどのくらいですか?
最大許容マイクロモーター入力回転数は33,000 rpmで、
公称最大バー回転数は約165,000 rpmです。
3. モーターを40,000 rpmで使用できますか?
いいえ。
このハンドピースでは、
モーター入力回転数が33,000 rpmを超えないようにしてください。
4. どのバーが対応していますか?
Model EB1LとModel E1L-Xは、
標準Ø1.6 mmシャンクの
FGフリクショングリップバーに対応しています。
5. EB1LとE1L-Xの違いは何ですか?
EB1Lはブラックナノチタンボディと
3点内部注水スプレーを採用しています。
E1L-Xはステンレススチールボディと
1点外部注水スプレーを採用しています。
6. 一般的なチェアサイド用途にはどのモデルが適していますか?
Model EB1Lは、
内部注水を使用するチェアサイドおよび
一般的な臨床用途向けに設計されています。
7. 外部注水にはどのモデルが適していますか?
Model E1L-Xは、
1点外部注水スプレーを必要とする
対応モーター・MOS構成向けです。
8. 光ファイバー照明に対応していますか?
はい。
両モデルとも、
対応する光ファイバー電動マイクロモーターから
治療部位へ光を伝送します。
9. 1:5 ハンドピースをインプラント埋入に使用できますか?
いいえ。
インプラント埋入には通常、
トルクコントロール機能を備えた対応インプラントモーターと、
専用の20:1減速インプラント用コントラアングルが必要です。
10. 1:5 ハンドピースはどのようにメンテナンスしますか?
バーを取り外し、外面を清掃し、
注水経路をフラッシュしてください。
取扱説明書に従って注油し、
チャックとスプレー孔を点検したうえで適切に滅菌し、
十分に乾燥させてから保管してください。