4:1 Reciprocating Contra Angle Handpiece
Explore the KANEIKO Reciprocating Handpiece Collection. This page includes reciprocating handpieces engineered for precise back-and-forth motion during interproximal reduction, crown removal, veneer removal, and other restorative procedures. Suitable for controlled enamel reduction, adhesive removal, and sectioning applications, these handpieces deliver smooth operation, reliable cutting efficiency, and stable clinical control for daily use.
4:1 Reciprocating Contra-Angle Handpiece Series
More About 4:1 Reciprocating Contra-Angle Handpieces
Kaneiko 4:1 reciprocating contra-angle handpieces are designed for controlled interproximal reduction, contact opening, enamel contouring and proximal finishing in orthodontic, clear-aligner and restorative workflows.
Unlike a conventional rotary handpiece that turns continuously, a reciprocating contra-angle converts motor input into a controlled back-and-forward movement. This oscillating action allows compatible IPR strips to move progressively through narrow interproximal spaces while supporting tactile control and measured enamel reduction.
The collection includes the Kaneiko Reciprocating Contra Angle Model IPR Dental Handpiece , engineered for orthodontic cases, aligner treatment, lingual orthodontics, proximal finishing, polishing and selected restorative procedures.
Model IPR features a 4:1 contra-angle system, a maximum operating speed of 10,000 rpm, ceramic bearing, stable shaft and cartridge system, ISO-standard connector and E-type international connection.
Introducing Reciprocating Handpieces in Clinical Dentistry
Interproximal reduction, commonly known as IPR, is the planned removal of a controlled amount of proximal enamel to create space, improve tooth alignment or refine contact relationships during orthodontic treatment.
Because enamel reduction is irreversible, the amount removed should follow the orthodontic or clear-aligner treatment plan. The clinician should identify the prescribed reduction for each contact and measure the created space throughout the procedure.
A reciprocating handpiece supports this workflow by guiding compatible IPR strips through a controlled back-and-forward movement. Different abrasive grades and strip thicknesses may be used progressively for contact opening, enamel reduction, finishing and polishing.
The contra-angle head also supports access to posterior and confined interproximal areas where manual strip movement may be more difficult or time-consuming.
Clinical Applications
Orthodontic Interproximal Reduction
Supports measured enamel reduction to create the prescribed space during fixed orthodontic treatment.
Clear-Aligner Space Creation
Helps create planned interproximal space according to the digital aligner treatment sequence.
Lingual Orthodontic Procedures
Provides controlled interproximal access during suitable lingual treatment workflows.
Opening Tight Contact Points
Compatible opening strips can be used progressively to establish access before calibrated enamel reduction.
Controlled Enamel Reduction
Supports gradual enamel removal using strips selected according to the prescribed reduction amount.
Proximal Surface Refinement
Fine abrasive strips help reduce irregularities and microgrooves after the main reduction stage.
Interproximal Finishing
Supports smoothing of reduced proximal enamel surfaces before final polishing.
Final Proximal Polishing
Compatible polishing strips may be used to produce a smoother finished interproximal surface.
Selected Restorative Procedures
May support conservative proximal adjustment and finishing where controlled reciprocating access is appropriate.
Kaneiko Model IPR: Engineered for Controlled Interproximal Reduction
The Kaneiko Model IPR reciprocating handpiece is designed around the clinical requirements of precise interproximal treatment: stable movement, controlled accessory guidance, low vibration and practical compatibility with a suitable E-type motor.
Key product features include:
- 4:1 contra-angle system
- Controlled back-and-forward reciprocating movement
- Maximum operating speed of 10,000 rpm
- Working air pressure of 0.22–0.30 MPa
- Stable shaft and cartridge system
- Ceramic bearing for smooth movement
- ISO-standard connector
- E-type international-standard connection
- Noise level below 65 dB
- CA Ø2.35 mm application specification
- Autoclavable up to 135°C
These features support controlled interproximal procedures when the handpiece is connected to a compatible motor and used with the correct reciprocating IPR accessories.
Technical Specifications
| Specification | Details |
|---|---|
| Model | Model IPR |
| Handpiece Type | Reciprocating Contra-Angle Handpiece |
| Ratio | 4:1 |
| Movement | Back-and-Forward Reciprocating Motion |
| Maximum Operating Speed | Up to 10,000 rpm |
| Working Air Pressure | 0.22–0.30 MPa |
| Application Size | CA Ø2.35 mm |
| Bearing | Ceramic Bearing |
| Internal System | Stable Shaft and Cartridge System |
| Connector | ISO-Standard Connector |
| Available Connection | E-Type International Standard |
| Noise Level | Less Than 65 dB |
| Sterilisation | Autoclavable up to 135°C |
| Main Application | Interproximal Reduction, Orthodontic Space Creation and Proximal Finishing |
How the 4:1 Reciprocating System Works
The 4:1 contra-angle system receives rotational input from a compatible E-type motor and converts it into controlled reciprocating movement at the working accessory.
Instead of rotating continuously, the strip moves back and forward through the interproximal contact. This allows enamel reduction to be completed progressively while preserving tactile feedback.
The handpiece should be operated within its specified maximum speed of 10,000 rpm. The appropriate operating setting depends on the selected strip, contact tightness and clinical procedure.
Compatible IPR Strip System
Model IPR is intended for use with compatible reciprocating IPR strips, holders and working accessories designed for contact opening, enamel reduction, finishing and polishing.
The product specification lists a CA Ø2.35 mm application size. However, this does not mean that every conventional Ø2.35 mm rotary bur is suitable for the reciprocating IPR system.
Use only accessories that are designed to connect securely to the Model IPR handpiece and are approved for the intended reciprocating movement.
Different strip thicknesses and abrasive grades may be used sequentially. The selected system should provide clearly marked stages for opening, measured reduction, fine finishing and final polishing.
Recommended Interproximal Reduction Workflow
1. Confirm the Treatment Plan
Review the prescribed amount of enamel reduction required at each interproximal contact.
2. Assess the Contact Area
Evaluate contact tightness, tooth position, enamel condition, existing restorations and access before beginning.
3. Open the Contact Progressively
Begin with a suitable opening strip where required rather than forcing a thicker reduction strip into a closed contact.
4. Reduce Enamel Gradually
Progress through calibrated abrasive stages and verify the created space regularly.
5. Refine the Surface
Use a finer strip to reduce microgrooves and smooth the reduced proximal enamel.
6. Complete Final Polishing
Use a compatible polishing strip to improve proximal surface smoothness.
7. Measure the Final Space
Confirm that the completed reduction matches the prescribed treatment requirement.
8. Follow the Preventive Protocol
Complete the clinician’s preferred remineralisation or preventive procedure after IPR where appropriate.
Clinical Benefits
Controlled Back-and-Forward Movement
Reciprocating motion supports progressive access and enamel reduction without continuous rotary cutting.
Improved Interproximal Access
Compatible strips can reach narrow proximal surfaces and tight contact areas.
Measured Enamel Reduction
Calibrated strip stages support gradual space creation according to the orthodontic plan.
Contact Opening and Reduction in One Workflow
Different accessories may be used progressively for initial access, enamel reduction and surface finishing.
Improved Tactile Control
Stable handpiece movement helps clinicians monitor strip position and contact resistance.
Proximal Finishing and Polishing
Fine and polishing strips support refinement of the enamel surface after reduction.
Low-Noise Clinical Operation
Model IPR has a specified operating noise level below 65 dB.
Buying Considerations
- Compatibility with the intended E-type motor system
- Maximum operating speed of 10,000 rpm
- Availability of compatible reciprocating strip accessories
- Range of opening, reduction, finishing and polishing strips
- Clearly marked strip thicknesses for measured reduction
- Stable accessory retention during reciprocating movement
- Ceramic-bearing condition and movement stability
- Availability of replacement shaft and cartridge components
- Ease of cleaning, lubrication and sterilisation
- Access to servicing and replacement-part support
The handpiece should be selected as part of a complete interproximal reduction system. The available strip range and measurement options are as important as the handpiece mechanism.
How to Choose the Right Reciprocating Handpiece
Confirm the Main Procedure
Model IPR is designed primarily for interproximal reduction, orthodontic space creation, contact opening and proximal finishing.
Check Motor Compatibility
Confirm that the intended motor uses a compatible ISO-standard E-type connection.
Review the Operating Range
Ensure that the motor can be controlled within the handpiece’s maximum operating speed of 10,000 rpm.
Evaluate the IPR Accessory Range
Select a system with suitable opening, calibrated reduction, finishing and polishing strips.
Confirm Strip Retention
The strip holder and working accessory should remain stable throughout reciprocating movement.
Consider Maintenance Support
Confirm access to lubrication guidance, cartridge servicing and replacement components.
Motor and Connection Compatibility
Kaneiko Model IPR features an ISO-standard connector and E-type international-standard connection.
Before purchase, verify that the clinic’s intended motor connection matches the handpiece. The motor should also provide suitable speed control for operation within the listed maximum of 10,000 rpm.
Correct mechanical connection is essential for stable movement and power transmission. Do not force the handpiece onto an incompatible motor connection.
Maintenance and Sterilisation
Proper maintenance supports stable reciprocating movement, ceramic-bearing performance and reliable accessory retention.
After each procedure, remove the working strip or holder and clean the external surface according to the manufacturer’s instructions.
Lubricate the handpiece through the correct E-type connection or maintenance adaptor where required. Operate it briefly to distribute lubricant and remove excess oil before sterilisation.
Inspect the reciprocating head, shaft, cartridge and accessory holder regularly. Increased vibration, unusual noise, irregular movement or reduced retention may indicate that servicing is required.
Model IPR can be autoclaved up to 135°C. Follow the recommended sterilisation cycle and allow the handpiece to dry completely before storage.
Read the Kaneiko Dental Handpiece Maintenance Guide for additional cleaning, lubrication, inspection, sterilisation and storage guidance.
Professional Insight
In clinical practice, successful interproximal reduction depends on treatment planning, measurement and accessory selection rather than the handpiece alone.
A reciprocating handpiece supports controlled access, but the clinician must still monitor the reduction amount carefully. Excess enamel may be removed when an inappropriate strip thickness, excessive pressure or repeated unmeasured passes are used.
Contact opening, enamel reduction, finishing and polishing should be completed as separate stages. Starting with an aggressive strip before sufficient contact access has been established may make the procedure more difficult.
The final proximal surface should be evaluated for smoothness, contact relationship and the prescribed amount of space before treatment continues.
Benefits of Using the Kaneiko Model IPR Handpiece
- Supports controlled interproximal enamel reduction
- Provides stable back-and-forward reciprocating movement
- Supports orthodontic and clear-aligner space creation
- Helps open tight contact areas progressively
- Supports calibrated reduction, finishing and polishing
- Uses a ceramic bearing for smooth movement
- Connects to compatible E-type motor systems
- Operates at speeds of up to 10,000 rpm
- Provides low-noise operation below 65 dB
- Can be autoclaved up to 135°C
Frequently Asked Questions
1. What is a 4:1 reciprocating contra-angle handpiece used for?
It is used for controlled interproximal reduction, orthodontic space creation, contact opening, proximal finishing and polishing.
2. What is the maximum operating speed of Model IPR?
The maximum specified operating speed is 10,000 rpm.
3. How does reciprocating movement differ from rotary movement?
Reciprocating movement travels back and forward, while a conventional rotary instrument turns continuously.
4. Is Model IPR suitable for clear-aligner treatment?
Yes. It may be used for prescribed interproximal space creation during suitable clear-aligner workflows.
5. What accessories are used with the handpiece?
It is intended for compatible reciprocating IPR strips and holders used for opening, reduction, finishing and polishing.
6. Can conventional rotary RA burs be used?
The specification lists a CA Ø2.35 mm application size, but only accessories designed and approved for the Model IPR reciprocating system should be used.
7. What type of motor connection is required?
Model IPR uses an ISO-standard E-type international connection.
8. Does the handpiece automatically control the amount of enamel removed?
No. The clinician must select the correct calibrated strip and measure the created space throughout the procedure.
9. Can Model IPR be sterilised?
Yes. The handpiece is specified as autoclavable up to 135°C.
10. How should the reciprocating handpiece be maintained?
Remove the accessory, clean the exterior, lubricate according to the instructions, inspect the reciprocating mechanism, sterilise correctly and allow the handpiece to dry before storage.
4:1 レシプロコントラアングルハンドピース
4:1 レシプロコントラアングルハンドピースについて
Kaneiko 4:1 レシプロコントラアングルハンドピース は、矯正治療、クリアアライナー治療、修復治療における IPR(隣接面削合)、コンタクトオープニング、 エナメル質の形態修正、隣接面の仕上げを コントロールしながら行うために設計されています。
一般的な回転式ハンドピースが連続回転するのに対し、 レシプロコントラアングルはモーターからの回転入力を コントロールされた往復運動に変換します。 この往復運動により、対応するIPRストリップを 狭い隣接面へ段階的に進めながら、 触覚的なコントロールと計画的なエナメル質削合をサポートします。
このコレクションには、 Kaneiko Model IPR レシプロコントラアングルハンドピース が含まれています。 矯正治療、アライナー治療、舌側矯正、 隣接面の仕上げ・研磨、および一部の修復処置に対応するよう設計されています。
Model IPRは、4:1コントラアングルシステム、 最大作動速度10,000 rpm、セラミックベアリング、 安定したシャフト・カートリッジシステム、 ISO規格コネクターおよび国際規格Eタイプ接続を備えています。
臨床歯科におけるレシプロハンドピース
IPR(Interproximal Reduction:隣接面削合)は、 矯正治療においてスペースを確保し、 歯列を整えたりコンタクト関係を調整したりするために、 計画された量の隣接面エナメル質を削合する処置です。
エナメル質の削合は不可逆的であるため、 削合量は矯正またはクリアアライナーの治療計画に従う必要があります。 各コンタクトで指定された削合量を確認し、 処置中も形成されたスペースを継続的に測定することが重要です。
レシプロハンドピースは、 対応するIPRストリップをコントロールされた往復運動で動かすことで、 このワークフローをサポートします。 異なる研磨粒度や厚さのストリップを段階的に使用することで、 コンタクトオープニング、エナメル質削合、 仕上げ、研磨へと進めることができます。
コントラアングルヘッドは、 手動ストリップでは操作が難しい場合のある 臼歯部や狭い隣接面へのアクセスもサポートします。
主な臨床用途
矯正治療におけるIPR(隣接面削合)
固定式矯正治療において、
計画されたスペースを確保するための
コントロールされたエナメル質削合をサポートします。
クリアアライナー治療のスペース形成
デジタルアライナー治療計画に従って、
計画された隣接面スペースの形成をサポートします。
舌側矯正処置
適応する舌側矯正ワークフローにおいて、
コントロールされた隣接面アクセスをサポートします。
タイトコンタクトのオープニング
キャリブレーションされた削合を始める前に、
対応するオープニングストリップを段階的に使用して
コンタクトへのアクセスを確保します。
コントロールされたエナメル質削合
指定された削合量に応じて選択したストリップを使用し、
エナメル質を段階的に削合します。
隣接面のリファインメント
細かい研磨粒度のストリップを使用し、
主な削合後に残る表面の不整や微細な溝を整えます。
隣接面の仕上げ
最終研磨前に、
削合した隣接面エナメル質を滑らかに整えます。
最終隣接面研磨
対応するポリッシングストリップを使用し、
より滑らかな隣接面へ仕上げます。
一部の修復処置
コントロールされたレシプロアクセスが適する症例では、
保存的な隣接面調整や仕上げにも使用できます。
Kaneiko Model IPR:コントロールされたIPRのための設計
Kaneiko Model IPR レシプロハンドピース は、精密な隣接面処置に求められる 安定した動作、コントロールされたアクセサリー誘導、 低振動、対応するEタイプモーターとの実用的な互換性を考慮して設計されています。
主な製品特長:
- 4:1 コントラアングルシステム
- コントロールされた前後のレシプロ往復運動
- 最大作動速度 10,000 rpm
- 作動空気圧 0.22~0.30 MPa
- 安定したシャフト・カートリッジシステム
- スムーズな動作をサポートするセラミックベアリング
- ISO規格コネクター
- 国際規格Eタイプ接続
- 騒音レベル 65 dB未満
- CA Ø2.35 mm 適用仕様
- 最大135°Cまでオートクレーブ滅菌可能
対応するモーターに接続し、 適切なレシプロIPRアクセサリーと組み合わせることで、 コントロールされた隣接面処置をサポートします。
技術仕様
| 仕様 | 詳細 |
|---|---|
| モデル | Model IPR |
| ハンドピースタイプ | レシプロコントラアングルハンドピース |
| 変速比 | 4:1 |
| 動作方式 | 前後レシプロ往復運動 |
| 最大作動速度 | 最大10,000 rpm |
| 作動空気圧 | 0.22~0.30 MPa |
| 適用サイズ | CA Ø2.35 mm |
| ベアリング | セラミックベアリング |
| 内部システム | 安定したシャフト・カートリッジシステム |
| コネクター | ISO規格コネクター |
| 接続方式 | 国際規格Eタイプ |
| 騒音レベル | 65 dB未満 |
| 滅菌 | 最大135°Cまでオートクレーブ滅菌可能 |
| 主な用途 | IPR、矯正スペース形成、隣接面仕上げ |
4:1 レシプロシステムの仕組み
4:1コントラアングルシステムは、 対応するEタイプモーターから回転入力を受け、 作業用アクセサリーでコントロールされた レシプロ往復運動へ変換します。
ストリップは連続回転するのではなく、 隣接面コンタクト内で前後に動きます。 これにより触覚的なフィードバックを維持しながら、 エナメル質を段階的に削合できます。
ハンドピースは、 指定された最大作動速度10,000 rpm以内で使用してください。 適切な作動設定は、 使用するストリップ、 コンタクトの緊密度、 臨床処置によって異なります。
対応IPRストリップシステム
Model IPRは、 コンタクトオープニング、 エナメル質削合、 仕上げ、研磨用に設計された 対応するレシプロIPRストリップ、 ホルダーおよび作業用アクセサリーとの使用を想定しています。
製品仕様にはCA Ø2.35 mmの適用サイズが記載されています。 ただし、これは一般的なØ2.35 mmの回転式バーを すべてレシプロIPRシステムで使用できることを意味するものではありません。
Model IPRハンドピースへ確実に装着でき、 レシプロ往復運動用として設計・承認された 対応アクセサリーのみを使用してください。
異なる厚さや研磨粒度のストリップを 段階的に使用できます。 オープニング、計画的削合、 ファインフィニッシング、 最終研磨の各段階が明確に区別されたシステムを選択してください。
推奨IPRワークフロー
1. 治療計画を確認
各隣接面コンタクトで必要とされる
エナメル質削合量を確認します。
2. コンタクト部位を評価
処置前に、
コンタクトの緊密度、
歯の位置、
エナメル質の状態、
既存修復物、
アクセスを確認します。
3. コンタクトを段階的に開く
閉じたコンタクトへ厚い削合用ストリップを
無理に挿入するのではなく、
必要に応じて適切なオープニングストリップから開始します。
4. エナメル質を段階的に削合
キャリブレーションされた研磨ステージを順に使用し、
形成されたスペースを定期的に確認します。
5. 表面を整える
より細かいストリップを使用し、
微細な溝を減らして削合した隣接面を滑らかにします。
6. 最終研磨
対応するポリッシングストリップを使用して、
隣接面の表面性状を整えます。
7. 最終スペースを測定
完了した削合量が、
治療計画で指定された量と一致していることを確認します。
8. 予防処置を行う
必要に応じて、
IPR後に歯科医師が選択した再石灰化処置または
予防処置を行います。
臨床上のメリット
コントロールされたレシプロ往復運動
連続回転切削ではなく、
往復運動によって段階的なアクセスと
エナメル質削合をサポートします。
隣接面へのアクセス
対応するストリップにより、
狭い隣接面やタイトなコンタクト部へアクセスできます。
計画的なエナメル質削合
キャリブレーションされたストリップステージにより、
矯正治療計画に従った段階的なスペース形成をサポートします。
コンタクトオープニングから削合までのワークフロー
異なるアクセサリーを段階的に使用することで、
初期アクセス、
エナメル質削合、
表面仕上げへ進めることができます。
触覚的なコントロール
安定したハンドピース動作により、
ストリップ位置とコンタクト抵抗を確認しながら処置できます。
隣接面の仕上げ・研磨
ファインストリップやポリッシングストリップにより、
削合後のエナメル質表面を整えます。
低騒音設計
Model IPRの規定作動騒音レベルは65 dB未満です。
購入前に確認したいポイント
- 使用予定のEタイプモーターシステムとの適合性
- 最大作動速度10,000 rpm
- 対応するレシプロIPRストリップの入手性
- オープニング、削合、仕上げ、研磨用ストリップのラインアップ
- 計画的削合のための明確なストリップ厚表示
- レシプロ運動中の安定したアクセサリー保持
- セラミックベアリングの状態と動作安定性
- 交換用シャフト・カートリッジ部品の入手性
- 清掃、注油、滅菌のしやすさ
- 修理・交換部品のサポート体制
ハンドピースは、 IPRシステム全体の一部として選択することが重要です。 ハンドピースの機構だけでなく、 使用可能なストリップの種類や 削合量を確認するための測定方法も重要です。
適切なレシプロハンドピースの選び方
主な用途を確認
Model IPRは主に、
IPR、矯正スペース形成、
コンタクトオープニング、
隣接面仕上げ用に設計されています。
モーターとの適合性を確認
使用予定のモーターが、
対応するISO規格Eタイプ接続を採用していることを確認してください。
作動範囲を確認
モーターをハンドピースの最大作動速度
10,000 rpm以内でコントロールできることを確認してください。
IPRアクセサリーを確認
オープニング、
キャリブレーションされた削合、
仕上げ、
研磨に適したストリップを備えるシステムを選択してください。
ストリップ保持を確認
ストリップホルダーと作業用アクセサリーが、
レシプロ運動中も安定して保持されることを確認してください。
メンテナンスサポートを確認
注油方法、
カートリッジのメンテナンス、
交換部品の入手性を確認してください。
モーター・接続の適合性
Kaneiko Model IPRは、 ISO規格コネクターと 国際規格Eタイプ接続を採用しています。
購入前に、 使用予定のモーター接続がハンドピースに適合することを確認してください。 また、最大10,000 rpm以内で使用できる 適切な速度コントロール機能が必要です。
安定した動作と動力伝達には、 正しい機械的接続が重要です。 適合しないモーター接続へ 無理に装着しないでください。
メンテナンスと滅菌
適切なメンテナンスは、 安定したレシプロ運動、 セラミックベアリング性能、 確実なアクセサリー保持を維持するために重要です。
各処置後、 作業用ストリップまたはホルダーを取り外し、 メーカーの指示に従って外面を清掃してください。
必要に応じて、 正しいEタイプ接続部または メンテナンスアダプターから注油します。 短時間作動させて潤滑油を内部に行き渡らせ、 滅菌前に余分なオイルを除去してください。
レシプロヘッド、 シャフト、 カートリッジ、 アクセサリーホルダーを定期的に点検してください。 振動の増加、 異常音、 不規則な動作、 保持力の低下が見られる場合は、 メンテナンスが必要な可能性があります。
Model IPRは最大135°Cまで オートクレーブ滅菌可能です。 推奨される滅菌サイクルに従い、 保管前に十分に乾燥させてください。
清掃、注油、点検、滅菌、保管について詳しくは、 Kaneiko 歯科用ハンドピース メンテナンスガイド をご覧ください。
プロフェッショナル向けポイント
臨床におけるIPRの精度は、 ハンドピースだけではなく、 治療計画、 測定、 アクセサリー選択によって決まります。
レシプロハンドピースは コントロールされたアクセスをサポートしますが、 歯科医師は削合量を慎重に確認する必要があります。 不適切なストリップ厚、 過度な圧力、 測定を行わない反復操作は、 過剰なエナメル質削合につながる可能性があります。
コンタクトオープニング、 エナメル質削合、 仕上げ、 研磨は、 それぞれ別の段階として行うことが重要です。 十分なコンタクトアクセスを確保する前に 粗いストリップから開始すると、 処置が難しくなる場合があります。
処置後は、 隣接面の滑らかさ、 コンタクト関係、 計画されたスペース量を確認してから 次の治療段階へ進んでください。
Kaneiko Model IPR ハンドピースのメリット
- コントロールされた隣接面エナメル質削合をサポート
- 安定した前後レシプロ往復運動
- 矯正・クリアアライナー治療のスペース形成をサポート
- タイトなコンタクトを段階的に開く処置をサポート
- キャリブレーションされた削合、仕上げ、研磨に対応
- スムーズな動作をサポートするセラミックベアリング
- 対応するEタイプモーターシステムへ接続
- 最大10,000 rpmで作動
- 65 dB未満の低騒音設計
- 最大135°Cまでオートクレーブ滅菌可能
よくあるご質問
1. 4:1 レシプロコントラアングルハンドピースは何に使用しますか?
IPR(隣接面削合)、
矯正治療のスペース形成、
コンタクトオープニング、
隣接面の仕上げ・研磨に使用します。
2. Model IPRの最大作動速度はどのくらいですか?
指定されている最大作動速度は10,000 rpmです。
3. レシプロ運動と回転運動はどのように異なりますか?
レシプロ運動は前後に往復します。
一方、一般的な回転式器具は連続して回転します。
4. Model IPRはクリアアライナー治療に使用できますか?
はい。
適応するクリアアライナーワークフローにおいて、
計画された隣接面スペース形成に使用できます。
5. どのようなアクセサリーを使用しますか?
オープニング、削合、仕上げ、研磨用に設計された
対応するレシプロIPRストリップおよびホルダーを使用します。
6. 一般的な回転式RAバーを使用できますか?
製品仕様にはCA Ø2.35 mmの適用サイズが記載されていますが、
Model IPRレシプロシステム用として
設計・承認されたアクセサリーのみを使用してください。
7. どのようなモーター接続が必要ですか?
Model IPRは、
ISO規格の国際標準Eタイプ接続を採用しています。
8. ハンドピースがエナメル質の削合量を自動的にコントロールしますか?
いいえ。
歯科医師が適切なキャリブレーションストリップを選択し、
処置中に形成されたスペースを測定する必要があります。
9. Model IPRは滅菌できますか?
はい。
最大135°Cまでオートクレーブ滅菌可能です。
10. レシプロハンドピースはどのようにメンテナンスしますか?
使用後はアクセサリーを取り外し、
外面を清掃してください。
指示に従って注油し、
レシプロ機構を点検したうえで適切に滅菌し、
十分に乾燥させてから保管してください。